Summary of Heat Loss Calculations Assessing overall heating requirements for building (E) Component U-ValueAreaHeat Loss Rate (W o C -1 ) Walls U walls.
Images and text from HKT Architects – Project Architects.
BRE Energy Efficient Office of the Future
Heating energy calculation methods Anti Hamburg Lecture TTK-UAS.
Zero-Carbon Rural Home Development.  Mark Horgan – SAE  Mark Lewis – SAE  Grant MacGregor – SAE  Darren Tannock - SAE  Etienne Hentzen - ME.
Improving the quality of life for people in Dorset, now and for the future Pete West Renewable Energy Development Officer Dorset County Council Wessex.
CC-124 Growth Kinetics (Light Intensity Results) Bojan Tamburic 20/10/2009.
Photovoltaic “Parallel System” for Duke Farms Group Members Trecia Ashman Paola Barry Mukti Patel Zarina Zayasortiz.
Optimization Of Net Zero Energy Houses Gary Proskiw, P. Eng. Proskiw Engineering Ltd.
 Site  Requirements  Local Resources  Initial layout ideas  Brief material selection  Supply options.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
ENERGY SOURCES GOAL: The student will understand the difference between renewable and nonrenewable energy sources and will be able to describe the abilities.
How to use the DEEP LeCCATo Life Cycle Costing Tool DEEP Life Cycle Cost Analysis Tool How to use the tool The DEEP Toolkit. TOOL 2.b.Life Cycle Cost Analysis.
Best Practices in Energy Efficiency and Renewable Energy in Commercial Buildings EGNRET 28 January 2007.
European Solutions Group Members: Iain Gauld Michael Allan Scott Mackay Elisa Massé Helena Cortina.
Lamma Power Station Solar Power System. 2 Content Project Background Site Selection Amorphous Silicon Thin Film Photovoltaic System Environmental Benefits.
Massachusetts High-Performance Green Schools – Case Study Whitman-Hanson Regional High School Library & Media Center. This projects features include utilizing.
Data Centre Design. PROJECT BRIEF Develop a low energy data centre for a major computing company. Building is to be a prime example of sustainable, low.
NET ZERO HOUSE Etienne Hentzen Mark Horgan Mark Lewis Grant MacGregor Darren Tannock.
Solar Energy Physics Three forms of solar energy.  Passive Solar  Active Solar  Photovoltaic.
Now it is fixed. BILL ANALYSIS. RETRO-COMMISSIONING BENCHMARKING Note, this case is extreme but it’s not alone. It’s roughly 2.5 times the average use.
Passive House Seminar for Professionals from the Building Sector
Designing Solar PV Systems (Rooftops ). Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar.
Energy use in buildings Dr. Atila Novoselac Associate Professor Department of Civil, Architectural and Environmental Engineering, ECJ
ENERGY MANAGEMENT. A combined design and management function which embraces the disciplines of engineering mathematics accounting operations research.
USES OF SOLAR ENERGY Dimitar Dimitrov Associate Professor Faculty of Electrical Engineering and Information Technologies.
Sustainability in Non Domestic Construction By Professor Christopher Gorse – licensed under the Creative Commons Attribution – Non-Commercial – Share Alike.
Link Building PV project By: Culver Matt Labaume Natasha Narnio Guillaume Roux Arnaud Stanton Andrew Thompson Matt Troyano Joana ENS Renewable.
BY: RALIAT O. ALABI SOLAR ENERGY. HOW TO STORE THE ENERGY Through the use of a technique used in thermal plants Water is in one thermotank while molten.
Solar Systems Applications in Cape Town Background: –DmE projected impact of RE in 10 years is dismal ( GWh/pa) –Because it is judged against poor.
 Design a data centre for a large computing company  To have high efficiency standards  Utilise renewable technology  To be an exemplar in design.
Zero Energy Home Samantha Aherne Sarah Krisher Jordan Matteo Jim Wolfe October 14, 2010.
An Example of Residential Solar Retrofit Shawn Fitzpatrick, P.E. Energy Engineer Advanced Energy September 30, 2014.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
0 Load Calculation Manual Output : 1. Screen Outputs (Results, Pareto Chart, Hourly Estimation) 2. Optional Outputs (*CLTD.txt, *TETD.txt) 3.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
Site Location: Site Location: Gap Site at Bath Street and Pitt Street Plot: Plot: 50m x 50m Building Area: Building Area: 4000m 2 maximum Building Height:
1 NBS-M016 Contemporary Issues in Climate Change and Energy 2010 Revision Session Some worked examples N.K. Tovey ( 杜伟贤 ) M.A, PhD, CEng, MICE, CEnv Н.К.Тови.
A Closer Look at Energy Demands: Quantification and Characterisation.
Btec level 2 Construction UNIT 3 Sustainable Construction-energy use.
FUTURE CITY PROJECT Distribution and Use of Energy Mark Casto/ Program Staff EMBHSSC
Power to the Coast Project Presented by: Su Wei Tan Industrial Research Ltd.
Web: Tel: www.apwe.co.uk Aeolus Power NFU Annual Conference 2016 ICC Birmingham Victoria Griffiths – CEO Aeolus Wind Power.
Town of Woodbridge Beecher Road School Infrastructure & Energy Upgrade Presentation to Board of Education December 17 th, 2012 AKF John B. Rice, PE, LEED.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: Nov. 30, 2009 Calculation of the integrated energy performance of buildings.
Microgeneration Karl Letten – Change Programme Support Officer (Environment) Change Management.
Case application: Insulation and glazing, The Netherlands Harry Vreuls, NL Agency Workshop: Harmonization in Energy Savings Calculation: How To Fit International.
Energy Efficiency in Jamaica’s Building Code:
Solar photovoltaic (PV)
Institute for Energy and Transport
Jan 2016 Solar Lunar Data.
Low Energy Building Design 2010
Under floor Heating Graduation Project submitted By: Adli Mosleh
bre Innovation Park Visitor Centre:
[16469] Low Energy Building Design
Average Monthly Temperature and Rainfall
Energy Saving Concepts and Opportunities in Foundry (A case Study)
NET-ZERO-ENERGY (NZE) WASTEWATER TREATMENT PLANTS (WWTPs)
Application Portfolio: Fort Carson Solar Project
Gantt Chart Enter Year Here Activities Jan Feb Mar Apr May Jun Jul Aug
“DESIGN OF GRID-CONNECTED PV SYSTEM”
THE STUDY OF SOLAR-WIND HYBRID SYSTEM PH301 RENEWABLE ENERGY
Electricity Cost and Use – FY 2016 and FY 2017
Presentation transcript:

NET ZERO HOUSE Etienne Hentzen Mark Horgan Mark Lewis Grant MacGregor Darren Tannock

RECAP  Rural design option  Tasks assigned  Geometry  Materials  Lighting and Ventilation  Energy Systems  Renewable Energy  Simple bungalow design  Climate and site data for surrounding area

GANTT CHART

GEOMETRY  Optimum roof pitch 35˚  Garage added on West façade  Finalised sizing of windows etc.  Design optimised  Open plan living

LIGHTING  Design of the house on DIALux  Simulation parameters:  White walls and ceiling with 90% reflection  Windows with 10% reflection and 70% transmittance  Light coloured wood on the floor with 52% reflection  Location of the house: Glasgow  Date of the simulation: 21st March 2013

LIGHTING  Natural lighting results;

LIGHTING  Artificial lighting model

LIGHTING  Artificial lighting results

LIGHTING  House lighting installation

LIGHTING  Lighting energy consumption;  Average hours of daylight in Scotland = 12,5 hours  This is the duration of the day in mid-March

MATERIALS  Ceiling / Floor  Exterior Walls

HEATING LOAD CALCULATIONS  Degree-day method (internal gains assumed at 3.5 Celsius internal gain)  20 Celsius set-point, thus base temp Celsius for calculation.  Solar Calculation using Oban data (solar calculator available on Myplace)

HEATING LOAD CALCULATIONS MonthSouth Glazing GainNorthEastTOTAL SOLAR GAIN (kWh) Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec TOTAL

HEATING LOAD CALCULATIONS

TOTAL HEATING LOAD (kWh) HEATING COOLING Annual Total Losses (kWh) Annual Solar Gains (kWh)

HEATING LOAD CALCULATIONS

ELECTRIC CAR  Fiat 500e  111-horsepower electric-drive motor  116 miles per gallon  Range of km (81-99 miles) after one full charge (4 hours at 240 volts)  Fuel consumption rate of 29kWh per 100 miles. (source : Coupe-Image jpg)

ELECTRICAL DEMAND  Assuming electric car is driven on average 50 miles per week (2600 miles per year) with a fuel consumption rate of 29kWh per 100miles;  29kWh * (2600/100) = 754 kWh/year

RENEWABLE SYSTEMS  Renewable energy sources considered:  Ground Source Heat Pump  Small Wind Energy Converter  Photovoltaic Panels

GROUND SOURCE  Ground Source Heat pumps are notoriously hard to generate data for.  Various case studies in cold climates suggest that ground source heat pumps can be used to great effect.  However, as sizing a heat pump system would involve to many uncertainties, it was decided not to continue with this energy source.

WIND POWER  The average site wind speed as specified by NOABL is 5.5m/s at 10m above ground level.  There is an abundance of wind power to be had at the site.  The situation is made better still by the fact the turbine will be placed at the brow of a shallow hill.

TURBINE SELECTION  All turbines are fairly quiet (<45Dba), and receive no noise penalty.  Values are obtained by determining the power in the wind, using the equation:  All values obtained should be considered conservative.  All turbines come with packages including inverters and grid connections.  All turbines have no cut out speed, and a similar survival speed. TurbineRated Power 5.5m/s Swept Area (m2) Output pa at 5.5m/s Proven 66kW kWh Eoltec Scirocco6kW kWh Evance R90005kW kWh

TURBINE SELECTION  Eoltec Scirocco is the best choice.  Highest power yield  Lowest noise output  Lowest weight

SOLAR POWER  European Commission Joint Research Council rates the site at around 900kW/h per m2 per year. Met Office data is similar to this figure.  Wunderground.com also gives a value obtained from NASA for the site that is in keeping with this figure, and this data shall be used in calculation of solar gains.  Solar Energy can provide useful power. JANUARYFEBRUARYMARCHAPRILMAYJUNE JULYAUGUSTSEPTEMBEROCTOBERNOVEMBERDECEMBER Total kWh/m2/Year = 1045 Average W/m2 = calculators/solar.html

PANEL SELECTION  Research was undertaken into different types of panel:  Panasonic (Sanyo) HIT system  Sharp ND-R245A6 Polycrystalline Silicon  Sharp NA-E135G5 Thinfilm Microcrystalline

PANEL SELECTION  119 W/m2 is the average irradiance for a year based on the solar calculator.  It is assumed that the PV panel will be placed at the optimum angle i.e. 35˚  It is assumed that on average the operating temperature will be around 25˚C taking into account the wind speed and air temperature. Output was determined using the equation:  The values obtained are considered conservative. PanelMax Power (W) Irradiance (W/m2) Output (kWh pa) Output (kWh pa) for 10 panels HIT N ND-R245A NA-E135G

PANEL SELECTION  Panasonic HIT N240 system is the best choice  Does not require extensive modification  Most efficient at warmer temperatures  Guarantee of 80% effectiveness after 25 years  Low Weight and thin profile  Professional fitting available

THANKS FOR LISTENING QUESTIONS?