Domestic Wastewater GPs. Domestic Waste (DW) Staff Permitting (407-897-4163) Dennise Judy – Program Manager Chuck LeGros – Section Supervisor Wilmott.

Slides:



Advertisements
Similar presentations
Completing a new DBS Form: Guidance notes for Safeguarding Officers June 2013.
Advertisements

Drawings of Sufficient Detail
Water & Wastewater Construction Back Forward Wastewater Treatment Plant and Pump Station Improvements, Haverhill, MA.
Wakulla County Sewer Project Eutaw Utilities Presentation April 7, 2011.
PIPE CULVERT By CH. VENKATARAMAIAH.
Skyward Purchasing. Requirements for a Purchase Order Who What When Where Proof of Co-op status: – Region 7 – TCPN – Buyboard – TXMAS (State) – Term Contracts.
Water Main Extension Permits Interplan LLC Richard Lott, P.G., P.E. Program Manager-Drinking Water February 18,
Guidelines for accepting Report of Water Right Conveyance Forms (100%) 1.Terminology 2.Questions to ask yourself when reviewing a report of water right.
2012 Plumbing Codes International Plumbing Code Uniform Plumbing Code David McCarthy, P.E. City of Phoenix.
Using GIS for Utility Mapping and Asset Management Sanitary Sewer, Storm Sewer, and Water Distribution City of Mason City Jessy Willadsen - Mason City.
Chapter 20 Plumbing Plans.
2010 DCA CDBG Applicants’ Workshop New for 2010 & Important Reminders.
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
Connecticut Department of Energy and Environmental Protection.
Checkout of Grassed Waterways Beth E. Clarizia, P.E. Agricultural Engineer.
December 4, 2014 Macon, Georgia Georgia Mountains Regional Commission.
The State Water Project, Unauthorized Encroachments and the California Water Code State of California Department of Water Resources Division of Operation.
CORRESPONDENCE This module is to be used in assisting associate staff members with guidelines to follow when preparing correspondence.
11 City of Hallandale Beach Water, Wastewater and Stormwater Facilities Plan Public Meeting.
NPDES Primer for Executive Officers of Wastewater Facilities Indiana Department of Environmental Management Office of Water Quality Compliance Branch.
FORM 1000 – APPLICATION TO DRILL, RECOMPLETE OR REENTER.
Greenfield District Utility/RR Engineer, INDOT
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
SPDES General Permit for Stormwater Discharges During Construction Activity GP Mike Jurkowski, CPESC, NYSDOT - Summary of Changes From GP
Welcome Please set all cell phones to vibrate..
FILING REQUIREMENTS FOR THE SURPLUS LINE ASSOCIATION OF CALIFORNIA THE SURPLUS LINE ASSOCIATION OF CALIFORNIA CREATING A BATCH.
Remarks will print on the completed form Generate Quantity Book Entry Generate Pay Quantity.
CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems.
Matthew Udenenwu Waste Permits Division 2015 TCEQ Environmental Trade Fair.
Class Description In the class today we will be discussing how to properly file the P-17 report. The P-17 form is used by an operator when they are surface.
The Future of Sludge Disposal: A Fresh Perspective after Sandy Jim Meehan – Executive Director Rahway Valley Sewerage Authority.
SITE LOCATION AND DESIGN APPROVAL FOR DOMESTIC WASTEWATER TREATMENT WORKS GARY SOLDANO, P.E. SOUTHEAST REGIONAL OFFICE SUPERVISOR TECHNICAL SERVICES UNIT.
Annexation 480 CHELSEA ROSE ANNEXATION PUBLIC INFORMATION MEETING AUGUST 11 TH, 2015.
5.1.9 Student Book © 2005 Propane Education & Research CouncilPage Installing Propane Dispensers Successful propane dispenser installations are.
Event Planning Worksheet Event Planning Worksheet Time Line Field trip form Money, receipts and cash box Money, receipts and cash box Purchase Order form.
Wausau Department of Public Works - GIS Division Application of GIS Technology to Municipal Utility Operations Developing a Digital Inventory for Water,
Central Office Appraisal Branch Presents: Preparation of a Project Report Form TC Instructors, Ron Terry & Ron Carrico.
Construction Review LaVon M Marshall Greenfield District Utility/RR Engineer, INDOT June 11, 2015.
WYDOT CLEARING UTILITIES Keri Bohlmann, P.E. Utilities & DSS Supervisor.
Lift Station No. 1 and 2 Force Main Replacement Ronald Wastewater District Summer 2015.
Planning Commission Public Hearing: SUB Proposed 6-lot Subdivision at Bland Circle December 2, 2015.
A Volunteer Supervisor’s Guide to Volunteer Connection a modern, online volunteer management solution.
Smoke Testing Information
CE 3372 WATER SYSTEMS DESIGN Lecture 09: Report writing and cost estimating.
Records Storage and Destruction at Iron Mountain By Shan Jin, MLIS, CRM, CIP Records Analyst Queen’s University Archives January 2015.
Entity Relationship Diagram (ERD). Objectives Define terms related to entity relationship modeling, including entity, entity instance, attribute, relationship.
How to Submit a New Human Ethics Behavioral Application.
CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems.
Civil Engineering Surveying Roy Frank. Basic Route Survey and Design 1.Concept for Route 2.Reconnaissance Study 1.Small scale mapping of region (1”-500’
Village of Naples and Hazlitt 1852 Vineyards Sewer Feasibility Study.
How to CORRECTLY Complete a TEASE Access Request Form.
MyCLSS v.2 Critical Issues and Amend Checklist. Critical Issue After receiving final returns, SGB staff will perform a review according to a list of critical.
Travel or Conference Training Sponsored by Classified Senate.
Yvonne Baker Environmental Scientist Staff Rules for Receipt of Sewage Sludge for Disposal/Treatment.
26 – Wastewater Conveyance System Design 2
David Kurz, P.E. Lead Wastewater Engineer
Innovation North-Side Neighborhood Access Feasibility Study
Water & Wastewater Capacity Charge Work Shop
Coursework guidelines
Traffic Control Plan Development Course
Water Department has Six Divisions
PLUMBING PLANS CHAPTER 31
Campus ESSA Grant Packet Training
Georgetown county water and sewer district
Enrollment Agreement How to Complete Your
Research Phase, Indiana 811, Initial Notice, Verification
Flow chart to determine whether coverage is required
Drawing of Sufficient Detail (DOSD)
Presented by Ryan Wilcoxson and Jennifer Hawkins
Shaver Creek Permitting
Presentation transcript:

Domestic Wastewater GPs

Domestic Waste (DW) Staff Permitting ( ) Dennise Judy – Program Manager Chuck LeGros – Section Supervisor Wilmott Brown, P.E. – WWTF and CS Mala Choksi- WWTF and CS Sherry Cook – WWTF and CS Cindy Stafford – General Permits Phil Kane – Biosolids Amy Ley – Section Secretary Amanda Ferree (co-op) – C of C/permit determination Ryan Fields (co-op) – C of C/permit determination

When Do I Use GPs? All C/T systems except: “Alternative” systems – low-pressure, vacuum, not a normal gravity/forcemain system “Dryline” systems – no plant capacity, no existing point for connection Non-contiguous systems

General “Permits” Requires advanced notice of AT LEAST 30 DAYS; $250 Application Fee Fill in ALL blanks – initials or “X” Include the signed/sealed sketch showing mains, manholes, lift stations, points of connection, and required valves Give a good explanation for all “X-ed” items

DO NOT SUBMIT... Plan/profile sheets Lift station calculations storm water plans contour maps construction notes/details more than one copy of anything Do NOT leave anything BLANK on the APPLICATION!!!!!!!

Sketches for GPs Must be signed/sealed and be readable (clear) Only need to see what is listed on Page 1 of 11 of the form – No notes 1 Page (but no more than 3) – We will not accept plan/profiles or a full set of drawings – MUST SHOW EXISTING POINT OF CONNECTION

To Use the GP Utility must “X” the proper box on Page 10 of 11 The only “0” flow projects that can be permitted with a GP are relocation or rehabilitation of existing cleared- for-service projects Utility must have adequate capacity

For Individual Permit and GPs Just 1 form and 1 sketch/set of drawings All initials and signatures must be original Project Description (pg 2)– List all proposed pipe (diameter and length), total number of manholes to be constructed, total number of lift stations to be constructed Pump Station Data table must be properly filled out with all the requested information for each lift station

The Checklist (Individual and GP) Use an “X” if it is not provided/needed and give and explanation “Not applicable” is not an acceptable explanation for “X’ing” an item “Private Lift Station” is not an acceptable explanation “E-One lift station (not required)” is not an acceptable explanation

The Checklist (Individual and GP) Do not change anything within a checklist item – “X” and explain. Example: Item 78 – if using 2” FM, this item should be “X’ed” and explained that you are meeting 2 ft/sec in 2” FM – DO NOT cross out the 4” and write in 2”

Pay attention to these items: Cleanouts shall not be substituted for manholes in laterals greater than 150 feet in length Must meet 2 ft/sec in ALL proposed forcemains or submit for an individual permit

Clearances Make sure any permit conditions are addressed Note any deviations and include an as- built with the clearance For partial clearances it is best to send a sketch with the complete portion highlighted (yellow highlighter only)

Clearance may be a problem if…. You used the GP but then modified your project during construction, especially if you didn’t correspond with the Department. You installed piping or appurtenances that were not permitted. You didn’t install something that was required.