1 2 3 4 5 6 7 8 BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.

Slides:



Advertisements
Similar presentations
INTRUSION ALARM TECHNOLOGY
Advertisements

SCW9057 Key Features/Benefits
SK-ACP Installation Overview
RK600 / RK600e Product Training
Signals By Spreadsheet 4/12/2015 DIO.pptxSlide 1 Signals by Spreadsheet Distributed Input/Output Please turn your volume control up to hear audio.
Integrated Technology!
TagMaster Training 2013 GEN4 Software Applications
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
22 March Controller Diagnostics. 22 March Topics Covered: Diagnostics that allows you to check basic controller and reader functionality through.
EMerge Browser Managed Security Platform Module 2 Hardware install.
GS3055-I GSM Universal Wireless Alarm Communicator

Trouble - Shooting ELR - Electric Latch Retraction.
SAC844 Anviz Online Training Lesson 8
MineralScan Lite Installation Guidelines Digital Control Lab, LLC NW 6 th Street, Suite F Gainesville, FL Main Unit power 90 – 240 VAC 50/60.
PXL-500/-510 Tiger Controller II
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
Training.
WELCOME EVERYBODY!.
CCTV SYSTEMS CAMERA POWER SUPPLIES.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
Purpose Learn how to use basic electronic equipment:
ZIGBEE Network Introduction Integrated with Zigbee or Bluetooth products Operation voltage : DC 7V ~ 40V. RS232 Interface Meets or Exceeds TIA/EIA-232-F.
USER INTERFACE CONTROL MODULE S ECURE IT : Automated Laptop Security System University of Pennsylvania School of Engineering and Applied Science Electrical.
INTRUSION ALARM TECHNOLOGY
AVL USER GUIDE (GSM) Automatic Vehicle Locator Manual Korea 위치정보통신 TEL: FAX:
January 2005 Bewator Entro 5 An introduction.
Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Doc. Ver. : V1.10 Feb., R&D Center Union Community Co., Ltd. Installation &
Instrumental Analysis Electrical Components and Circuits.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Getting Started With an Unmanaged Switch HUE-500.
Installation Guide for AC-1000RF & SA V1.6 Installation Guide for AC-1000RF & SA V1.6 Version Eng1.10 Jul., Union Community Co., Ltd.
Your Connectivity Partner. Locations Main Office: High Tech Products Lallio, Italy USA Office: HTP Connectivity Parsippany, NJ.
GS3055-I GSM Universal Wireless Alarm Communicator
GS3055-I Installation Process
Physics 2225: Working With Electronic Equipment Purpose  Learn how to use basic electronic equipment: Digital multi meter Oscilloscope Function generator.
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
Basic Stamp OEM module By Wilmer Arellano. 2  The BASIC Stamp 2 OEM is a discreet component version of the BS2 which may be purchased in kit form. 
ADT490 TroubleShooting Locating Opens A. 2 Introduction Breakdown in Circuit Integrity -> Trouble Metallic continuity interrupted an “ open ” occurs System.
EeePC – Ubuntu Running pvMon USB cable Phidget I/O Controller Photovoltaic panel Power/System Connections I V PV charger Cont. Phidget I/O Controller +12.
FIREPOWER BY SABURKE. Distributed Power Modules Model 5495Model Amps9 Amps.
New product introduction:
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
WRI400 WIRELESS READER INTERFACE Technical Services Training for the WRI400 Launched April 2011 June 16Technical Services – Engineering Support1.
Submitted by:.  Project overview  Block diagram  Power supply  Microcontroller  MAX232 & DB9 Connector  Relay  Relay driver  Software requirements.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
Door Controller Device. 2 Door Controller Device (DCD) The DCD is the “Remote Brains” of the system. It is the controller device located at each access.
Power Supply. 2 Power Supply w/Line Conditioner The power supply is the heart of the Millenium System. It can support between 15 DCD boards (power for.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
Hearty Welcome!.
CMV-NET Chigo VRF Network Centralized Control System
Motor board Rework Andre Pool Confidential
Brooks Expert Support Tool (BEST) Software
COSEC ARC IP based Access Control Panel.
Elevator Control Unit.
Site Controller Unit and Trunk Interface Unit
BO-A210N User Manual 1. Registration methods 2. Delete methods
IBM PC Controlled Keypunch4b
Connections Topology of Apollo ACS.
GROUND-FAULT GROUND-CHECK MONITOR
Slides include notes (more details about every slide information).
Module 1 – Power Supply AMC APS-PBC-60
Presentation transcript:

BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM FAIL DRM MODULE ENABLED RUN MODE 1 RUN MODE 2 ADDRESS 1 5INVERT RELAY OPERATION RELAYS NOT INVERTED 5INVERT RELAY OPERATION RELAYS INVERTED 8DRM MODULE ENABLED 8 DRM MODULE DISABLED DRM MODULE ENABLED 6 7 ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM FAIL 1 2 RUN MODE 1 RUN MODE RUN MODE 1 RUN MODE RUN MODE 1 RUN MODE 2

ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 1 FLOOR 1 TO ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 2 FLOOR 17 TO ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 3 FLOOR 33 TO ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 4 FLOOR 49 TO ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 5 FLOOR 1 TO ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 6 FLOOR 17 TO ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 7 FLOOR 33 TO ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 FLOOR 49 TO 64

ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16

AC AC B+ B- ST TP TP 1K5 OHM LED 16VAC 40VA MAX TRANSFORMER 50/60Hz 40VA MAX MAINS INPUT +12V AUX AC AC B+ B- ST TP TP

4Ah (MIN) GEL CELL BACKUP BATTERY N+ N- NA NB TP TP F+ F- FIRE CONTROL SYSTEM VDC mA TO NEXT ELEVATOR CONTROLLER AC AC B+ B- ST TP TP

N+ N- NA NB CONTROLLER EOL ON 0V B- A+ 12V

S+ S- SA SB TO FIRST SLAVE FLOOR CONTROL MODULE. PRT-PX16 IN FLOOR CONTROL MODE. TAMPER SWITCH N+ N- NA NB TP TP N+ N- NA NB NETWORK COMMUNICATIONS INPUT FROM SYSTEM CONTROLLER OR PREVIOUS PROTÉGÉ SYSTEM MODULE

NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM

NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM + IN1 - + IN2 - INPUTS ON THE DRM DAUGHTER BOARD RELAY CONTACTS ON THE MAIN ELEVATOR CONTROL BOARD SEE TEXT BUTTON VOLTAGE COMMON IN ELEVATOR CONTROL SYSTEM

NO COM NC RELAY 1 FLOOR SELECT BUTTON IN ELEVATOR CAR FLOOR INPUT TERMINALS IN ELEVATOR CONTROL SYSTEM NORMAL CONNECTION REMOVED LOOP TERMINAL ADDED BY ELEVATOR COMPANY LOCATED IN ELEVATOR CONTROL SYSTEM + IN1 - + IN2 - INPUTS ON THE DRM DAUGHTER BOARD RELAY CONTACTS ON THE MAIN ELEVATOR CONTROL BOARD SEE TEXT BUTTON VOLTAGE COMMON IN ELEVATOR CONTROL SYSTEM

+ IN1 - + IN2 - INPUTS ON THE DRM DAUGHTER BOARD AC AC B+ B- + - ST POWER CONNECTOR ON MAIN ELEVATOR CONTROL BOARD

EOL EOL ONEOL OFF 350mA 700mA 350mA 700mA FIRE OVERRIDE FIRE OVERRIDE EOL

ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 ADDRESS 16 ADDRESS 32 ADDRESS 64 SPECIAL FUNCTION

N+ N- NA NB PC OR HOST CONTROL SYSTEM CONNECTED TO A ACC-485 SERIAL INTERFACE EOL OFF EOL ON +12 0V A+ B-

AC AC B+ B- + - ST 7.5Ah GEL CELL BACKUP BATTERY N+ N- NA NB TP TP F+ F- FIRE CONTROL SYSTEM VDC mA TO NEXT IRC RELAY CONTROLLER

N+ N- NA NB FROM PREVIOUS CONTROLLER TO NEXT IRC CONTROLLER TP TP F+ F- TAMPER SWITCH

AC AC B+ B- ST TP TP COLD WATER PIPE GROUNDING EARTH PEG GROUNDING ROD TO OTHER EARTH CONNECTIONS ALREADY ATTACHED TO THE EARTH PEG OR WATER PIPE MIN AWG#14 SINGLE SOLID CONDUCTOR COPPER WIRE

N+ N- NA NB MODULE OR CONTROLLER SUPPLYING POWER TO NETWORKED DEVICES AUX+ AUX- N+ N- NA NB NEXT MODULES ON NETWORK

N+ N- NA NB READER EXPANDER SUPPLYING NETWORK POWER AUX+ AUX- S+ S- SA SB NEXT FLOOR CONTROL MODULE SLAVE DEVICES CONNECTED TO THE READER EXPANDER SLAVE COMMUNICATION INTERFACE USE THE N+, N-, NA AND NB TERMIANLS.

+ - D0 D1 L1 L2 BZ PRX-SAM READER CONNECTION RED BLACK GREEN WHITE ORANGE BROWN BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR NEGATIVE CONNECTION. +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER PRX-NANO NANO PROX PROXIMITY READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION -+-+ POWER SUPPLY 12VDC

+ - D0 D1 L1 L2 BZ R2 R2 R2 R2 R2 R2 R2 + - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD DATA 1 ENTRY UNIT EXIT READER READER #1 INPUT CONNECTION READER #2 INPUT CONNECTION

+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER + - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER

NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + BUZZER INPUT ALARM OUTPUT POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS

NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + DB9 RS232 POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS PIN 2 RXD PIN 3 TXD PIN 5 GND

NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + RS485 POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS NA NB COM

NC COM NO P1 I3 I2 I1 DOOR CONTACT NORMALLY CLOSED REQUEST TO EXIT NORMALLY OPEN +-+- ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + BUZZER INPUT ALARM OUTPUT POWER SUPPLY 12VDC PRX-SAM INTERFACE CONNECTIONS

NC CONNECTION SHOWN FOR LOCK RELAY ELECTRIC LOCKING DEVICE 1N4007 DIODE (SUPPLIED) - + POWER SUPPLY FOR LOCKING DEVICES MAX 30VDC

1K N.C. ZONE CONTACT N.C. TAMPER CONTACT N.C. ZONE INPUT COMMON AUX AUX Z1 COM Z2 Z3 COM Z4 + - DOOR1 REX1 SEN1 REN1 RESISTORS SHOULD BE LOCATED AT THE DEVICE ATTACHED TO THE ZONE ZONE INPUT SHOWN FOR ZONE 1

N.C. ZONE CONTACT N.C. ZONE INPUT COMMON AUX AUX Z1 COM Z2 Z3 COM Z4 + - DOOR1 REX1 SEN1 REN1 ZONE INPUT SHOWN FOR ZONE 1

+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PGM RDxxx:03 1K5 OHM LED +12V AUX ADDRESS 4 ADDRESS 8 ADDRESS 1 ADDRESS 2 ADDRESS 64 ADDRESS 16 ADDRESS 32 DEFAULT / RUN ADDRESS 1 ADDRESS 2 ADDRESS 4 ADDRESS 8 READER EXPANDER ADDRESS ADDRESS 64 ADDRESS 16 ADDRESS 32

CROSSOVER DIRECT ETHERNET CONNECTION 8 PORT ETHERNET HUB READER EXPANDER RJ45 ETHERNET CONNECTOR MULTIPLE ETHERNET CONNECTIONS USING A ETHERNET HUB ETHERNET

N+ N- NA NB SYSTEM CONTROLLER SUPPLYING NETWORK POWER AUX+ AUX- N+ N- NA NB NEXT MODULE ON NETWORK STANDARD ZONE EXPANDERS CONNECTED TO THE SYSTEM CONTROLLER COMMUNICATION INTERFACE USE THE N+, N-, NA AND NB TERMIANLS.

N+ N- NA NB MODULE NETWORK COMMUNICATIONS

CROSSOVER DIRECT ETHERNET CONNECTION 8 PORT ETHERNET HUB SYSTEM CONTROLLER RJ45 ETHERNET CONNECTOR MULTIPLE ETHERNET CONNECTIONS USING A ETHERNET HUB ETHERNET SYSTEM CONTROLLER RJ45 ETHERNET CONNECTOR ETHERNET SYSTEM CONTROLLER ONE SYSTEM CONTROLLER TWO

T2i R2i T1i R1i T1o R1o TELEPHONE LINE CONNECTION TERMINAL COLD WATER EARTH PIPE PRIMARY TELCO LINE OUT PRIMARY TELCO LINE RING AND TIP INPUT (T1i and R1i) SECONDARY TELCO LINE RING AND TIP INPUT (T2i and R2i)

N.C. ZONE CONTACT Z1 Z2 Z3 COM Z5 Z6 Z7 DR1 REX1 SEN1 DR2 REX2 SEN2

N.C. TAMPER 1K N.C. ZONE CONTACT Z1 Z2 Z3 COM Z5 Z6 Z7 DR1 REX1 SEN1 DR2 REX2 SEN2

B1+ B1- B2+ B2- P3 P4 CONNECTION SHOWN FOR BELL/SIREN 1 CP001: VDC SIREN WARNING DEVICE

B1+ B1- B2+ B2- P3 P4 CONNECTION SHOWN FOR CP001:03 1K5 OHM LED +12V AUX

350mA 700mA L H FIRE OVERRIDE FIRE OVERRIDE L H L H 350mA 700mA

N+ N- NA NB +12 0V TX RX RTS N+ N- NA NB AUX + - ACC-485 RS485 CONVERTOR SYSTEM CONTROLLER MODULE NETWORK CONNECTION SYSTEM CONTROLLER AUXILLARY TERMINALS USE SERIAL CABLE SUPPLIED WITH ACC-485 TO CONNECT TO THE PC SERIAL PORT

+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT SINGLE LED READER CONTROL RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR AUX- CONNECTION. +12V 0V PRX-NPROX NANO PROX PROXIMITY READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION ORANGE IS NOT USED IN SINGLE LED OPERATION N.O. BUTTON

+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT SINGLE LED READER CONTROL WITH BUTTON INPUT CONNECTION RED BLACK GREEN WHITE BROWN ORANGE BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR AUX- CONNECTION. +12V 0V PRX-NPROX NANO PROX PROXIMITY READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION ORANGE IS USED FOR BUTTON INPUT CONNECTION N.O. BUTTON

+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT YELLOW GREEN RED BROWN ORANGE +5V 0V CLOCK DATA OMRON READER MAGNETIC STRIPE READER TRACK 2 OUT COM IN INLINE +5V REGULATOR 50mA MAX OUTPUT PART CODE REG-5V +12V 0V CLOCK DATA CARD PRESENT REG-5V WIRING RED = INPUT (+9 TO +12V) COM = 0V WHITE = OUTPUT (+5V) IMPORTANT NOTE THE STANDARD OMRON/MAGTEK CARD READERS CAN HAVE AN INTERNAL MODIFICATION TO ALLOW THEM TO OPERATE FROM +12V WITHOUT THE INLINE REGULATOR AS SHOWN IN THIS DIAGRAM. PLEASE CONTACT ICT FOR FURTHER INFORMAITON. FOR THE CONNECTION OF OTHER MAGNETIC CARD DEVICES REFER TO MANUFACTURERS INSTALLATION MANUAL

+ - D0 D1 L1 L2 BZ R1 R1 R1 R1 R1 R1 R1 CONNECTION SHOWN FOR PROTÉGÉ SYSTEM READER 1 PORT RED BLACK GREEN WHITE ORANGE BROWN BLUE SHIELD CONNECT THE READER SHIELD TO A SUITABLE EARTH POINT. DO NOT CONNECT THE SHIELD TO A GROUND OR AUX- CONNECTION. +12V 0V DATA 0 DATA 1 GREEN LED RED LED BEEPER PRX-NANO NANO PROX PROXIMITY READER OR WIEGAND READER YELLOW YELLOW OUTPUT CARD PRESENT SIGNAL FACTORY OPTION FOR OTHER PROXIMITY READER CONNECTIONS REFER TO THE MANUFACTURERS INSTALLATION MANUAL 4 CORE CONDUCTOR BETWEEN READER AND CONTROLLER