New Nuclotron Beam Intensity Monitoring Subsystem V. Andreev, A. Butenko, A. Kirichenko, S. Romanov, G. Trubnikov, V. Volkov Veksler and Baldin Laboratory.

Slides:



Advertisements
Similar presentations
How does a network identify computers and transmissions?
Advertisements

“NUCLOTRON-M” - кеу element of NIKA A.D.Kovalenko.VHM Workshop, September 19, 2007, Dubna.
Data Acquisition Risanuri Hidayat.
Data Acquisition Concepts Data Translation, Inc. Basics of Data Acquisition.
Information Technology Foundations-BIT 112 TECHNOLOGY GUIDE FOUR Basics of Telecommunications and Networks.
Using an FPGA to Control the Protection of National Security and Sailor Lives at Sea Brenda G. Martinez, Undergraduate Student K.L. Butler-Purry, Ph.D.,
NMR Spectroscopy Tuning / Matching Shimming and Lock.
Unit 4 Sensors and Actuators
MEG Experiments Stimulation and Recording Setup Educational Seminar Institute for Biomagnetism and Biosignalanalysis February 8th, 2005.
Performance analysis of a Grid-based Instrumentation Device Farm Luca Berruti 1, Franco Davoli 1, Stefano Vignola 1, Sandro Zappatore 1 1 CNIT – University.
Development of a Linux- based small-size controller using PoE technology T. Masuda, T. Fukui, R. Tanaka SPring-8 ICALEPCS2005, Oct , Geneva, Switzerland.
1 Project supervised by: Dr Michael Gandelsman Project performed by: Roman Paleria, Avi Yona 12/5/2003 Multi-channel Data Acquisition System Mid-Term Presentation.
Design and Development of High Performance PC Based Logic Analyzer MSc Project by Rab Nawaz Advisor: Dr. Shahid Masud.
Objectives: Sampling of analog signal. Act as analyzer and terminal for pc. Project supervised by: Michael Gandelsman Project performed by: Roman Paleria,
1 Project supervised by: Dr Michael Gandelsman Project performed by: Roman Paleria, Avi Yona 26/4/2004 Multi-channel Data Acquisition System Final_A Presentation.
Measuring Performance Chapter 12 CSE807. Performance Measurement To assist in guaranteeing Service Level Agreements For capacity planning For troubleshooting.
Beam Loss Analysis Tool for the CTF3 PETS Tank M. Velasco, T. Lefevre, R. Scheidegger, M. Wood, J. Hebden, G. Simpson Northwestern University, Evanston,
Distributed Control Systems Emad Ali Chemical Engineering Department King SAUD University.
Group: CCM Project 1.2. EMERSON Emerson is a diversified global manufacturing company.  Provides innovative solutions to customers in the following areas:
Digital data acquisition1 Measuring ? „Wer misst, misst Mist.“ numeric result Sensing, Signal Processing Evaluation Physical/Chemical Property Physical/Chemical.
Networking Technologies
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
1 Networks and Telecommunications. 2 Applying Telecommunications in Business TELECOMMUNICATIONS – the transmission of data between devices in different.
ACOE2551 Microprocessors Data Converters Analog to Digital Converters (ADC) –Convert an analog quantity (voltage, current) into a digital code Digital.
Data Acquisition Data acquisition (DAQ) basics Connecting Signals Simple DAQ application Computer DAQ Device Terminal Block Cable Sensors.
NICA INJECTOR Brief remarks on the status based on recent presentations and publications.
Digital Signal Processing and Generation for a DC Current Transformer for Particle Accelerators Silvia Zorzetti.
8 Channel Fiber Optically Linked Data Acquisition System for Booster Modulators Tsatsu Nyamadi Norfolk State University Supervisor Rene Padilla Fermilab.
Digitization When data acquisition hardware receives an analog signal it converts it to a voltage. An A/D (analog-to-digital) converter then digitizes.
1 Plans for JINR participation at FAIR JINR Contributions: ● Accelerator Complex ● Condensed Baryonic Matter ● Antiproton Physics ● Spin Physics Physics.
The microIOC Family Gasper Pajor EPICS Collaboration Meeting Argonne National Laboratory June 2006.
MULTIMEDIA INPUT / OUTPUT TECHNOLOGIES INTRODUCTION 6/1/ A.Aruna, Assistant Professor, Faculty of Information Technology.
CEA DSM Irfu Spiral2 Injector diagnostics acquisition based on new hardware Françoise Gougnaud CEA Saclay IRFU - Françoise Gougnaud– Spiral2 Injector Diagnostics.
Peter Spiller, DIRAC Kick-off meeting Peter Spiller Design Study Group DIRAC kick-off meeting SIS100.
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
28/03/2003Julie PRAST, LAPP CNRS, FRANCE 1 The ATLAS Liquid Argon Calorimeters ReadOut Drivers A 600 MHz TMS320C6414 DSPs based design.
The Main Injector Beam Position Monitor Front-End Software Luciano Piccoli, Stephen Foulkes, Margaret Votava and Charles Briegel Fermi National Accelerator.
NUCLOTRON CONTROL SYSTEM (NCS) V.Andreev, E.Frolov, A.Kirichenko, A.Kovalenko, B.Vasilishin, V.Volkov Laboratory of High Energies, JINR, Dubna.
 It is the transmission of data from one place to another.  A data communication system is made up from hardware, software and communications facilities.
Status of the Source of Polarized Ions project for the JINR accelerator complex (June 2013) V.V. Fimushkin, A.D. Kovalenko, L.V. Kutuzova, Yu.V. Prokofichev.
NICA control system, beam diagnostics V.Andreev, E.Gorbachev, A.Kirichenko, D. Monakhov, S. Romanov, G.Sedykh, T. Rukoyatkina, V.Volkov VBLHEP, JINR, Dubna.
PHYSICAL PROJECT OF BOOSTER FOR NICA ACCELERATOR COMPLEX Alexey Tuzikov, Nikolay Agapov, Andrey Butenko, Alexey Eliseev, Viktor Karpinsky, Hamlet Khodzhibagiyan,
Information support of physical experiments on Nuclotron NEC’2003 Varna, Bulgaria V. Andreev, E. Frolov, B. Sveshnikov., B. Vasilishin., V. Volkov (JINR)
Tracking at the Fermilab Test Beam Facility Matthew Jones, Lorenzo Uplegger April 29 th Infieri Workshop.
4. Operations and Performance M. Lonza, D. Bulfone, V. Forchi’, G. Gaio, L. Pivetta, Sincrotrone Trieste, Trieste, Italy A Fast Orbit Feedback for the.
XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser Wojciech Jalmuzna, Technical University of Lodz, Department of Microelectronics and Computer.
ECE 101 Exploring Electrical Engineering Chapter 7 Data Acquisition Herbert G. Mayer, PSU Status 11/30/2015 Derived with permission from PSU Prof. Phillip.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
Trigger system for setup 2016 V. Rogov, V. Yurevich,D.Bogoslovski, S.Sergeev, O.Batenkov* LHEP JINR *V. G. Khlopin Radium Institute, St. Petersburg.
Joint institute for nuclear research Volkov V.I., Gorbachev E.V., Kirichenko A.E., Sedykh G.S. NEC’2015 The thermometry system of superconducting magnets.
Slow Control System at experiment D. Egorov Slow Control System at V. Shutov, D. Egorov, R. Nagdasev 1/15.
9530 T IMING C ONTROL U NIT Features TCU-1 Key Features 250ps timing resolution with < 50ps jitter 8 independent outputs with full individual programming.
Fundamentals of Information Systems, Sixth Edition
Data transmission system for 2D-SND at CSNS
RF acceleration and transverse damper systems
A.Sidorin, on behalf of the team PP PAC, JINR, Dubna, 16 January 2017
A. Martynov on behalf of accelerator division.
TANGO Standard Software for Nuclotron Beam Slow Extraction Control
V. Andreev, A. Butenko, V. Elkin , E. Gorbachev, V. Isadov, A
KRB proposal (Read Board of Kyiv group)
ПОЛНОЕ НАЗВАНИЕ ПРОЕКТА
LHC BLM system: system overview
M. Mehler1), H. Klingbeil1), B. Zipfel2)
Timing System GSI R. Bär / U. Krause 15. Feb. 2008
Interlocking of CNGS (and other high intensity beams) at the SPS
Data Acquisition (DAQ)
EPICS: Experimental Physics and Industrial Control System
Basics of Telecommunications and Networks
quadEM: New Beam Position Monitor & Electrometer Hardware and Software
Presentation transcript:

New Nuclotron Beam Intensity Monitoring Subsystem V. Andreev, A. Butenko, A. Kirichenko, S. Romanov, G. Trubnikov, V. Volkov Veksler and Baldin Laboratory of High Energy Physics, JINR, Dubna, Russia XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

Abstract A new Nuclotron Beam Intensity Monitoring Subsystem (NBIMS) is based on a Parametric Current Transformer (manufacturer: BERGOZ instrumentation). It allows Nuclotron beam current and intensity monitoring correlated with the main magnetic field signal (sampling rate is 100 kSamples/s). Common structure, electronic equipment, software and first results of the Subsystem are described in this report. XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

Nuclotron Facility The superconducting synchrotron Nuclotron is intended to accelerate nuclei and multicharged ions. Circumference251.5 m Magnetic fieldup to 2 T Particle Energyup to 6 Gev/u 39 runs has been performed XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

The Nuclotron Control System Two physical levels: Operator Control and Front End 17 geographically separated Subsystems Total number of points for meas. and control: ~ 3500 Fast Ethernet LAN as the System common backbone XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

NBIMS structure XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

Parametric Current Transformer XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ Ranges from ±20mA to ±20A Frequency response: up to 10kHz Inducing protection Manufacturer: BERGOZ Instr.

Analogue Function Generator XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ The 2-channels Counter is based on Altera EPN7128 The 14-bits DAC is based on AD 760 AFG works in 0…10V range 1 AFG bit corresponds to 0.1 Gs magnetic field value The Counter and the DAC are galvanic isolated

CyberResearch CMF 1622HRDA board XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ Multifunction Analog I/O Board for PCI 16/8 inputs (Single Ended/Differential Mode) Up to 250 kHz sampling rate 16 bits resolution 8 MSamples Local Acquisition Memory Possibility of external triggering

NBIMS working cycle XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

Reproduction of beam intensity XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ where U – voltage signal from the PCT, f – beam revolution frequency, B – main magnetic field, B(0) = B inj, k – constant of proportionality. The NBIMS properly works in 10 8 …10 12 intensity range for proton and deuteron beams.

NBIMS software XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ The NBIMS software complex (developed for.NET Framework) consists of three parts: Server – equipment management, data acquisition and processing, data providing to client Client – remote viewing of data from the Server Administrator – remote management of client connections to the Server

NBIMS software: Data presentation XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

NBIMS software: Remote Data Viewing XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ Remote viewing of the data is carried out by means of sockets technology via IP-network. Data transmission from the Server to multiple Clients is realized on “Publish-Subscribe” model. The Client sends to the Server a special request for subscription to NBIMS information. The Server either includes this Client to the “mailing list” or rejects the client request. After acquisition and processing of new data the Server dispatches it to all "subscribers”.

NBIMS software: the Client Modes XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ Extended Mode - the data with maximum time resolution is transferred from the Server. Sampling interval: 10 µs Data volume: ~ 10 Mbytes It is used for the machine precise tuning and investigations. In the Simple Mode only 30 Kbytes of the data is transferred. It is sufficient for representation of an overall chart of the accelerator cycle.

First results XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ The NBIMS was successfully used during two last runs of the Nuclotron. The Subsystem has proved as a powerful tool for accelerator tuning. Also some important machine investigations such as two step acceleration mode experiment, testing of the adiabatic capture equipment and energy evacuation system were carried out with help of the NBIMS.

NBIMS in the Adiabatic Capture Experiment XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________

Future plans XXII International Symposium on Nuclear Electronics & Computing ____________________________________________________________ Interface improvement: separate signals scaling on amplitude Optimal increasing of the signals time resolution for the Client in the Simple mode Web-support for external users