27 January 2010 Immanuel Gfall (HEPHY Vienna) Belle II SVD Mechanics and Cooling DEPFET Meeting Prag.

Slides:



Advertisements
Similar presentations
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Advertisements

24 June 2010 Immanuel Gfall (HEPHY Vienna) CO 2 Cooling for PXD/SVD IDM Meeting.
CO2 cooling for FPCCD Vertex Detector Yasuhiro Sugimoto KEK 1.
A Low Mass On-chip Readout Scheme for Double-sided Silicon Strip Detectors 13th February 2013 C. Irmler, T. Bergauer, A. Frankenberger, M. Friedl, I. Gfall,
Basic Refrigeration Cycle
Electrical QA Markus Friedl (HEPHY Vienna) IPMU, 19 March 2012.
Summary of the SVD session 19 March 2009 T. Tsuboyama (KEK)
The Origami Chip-on-Sensor Concept for Low-Mass Readout of Double-Sided Silicon Detectors M.Friedl, C.Irmler, M.Pernicka HEPHY Vienna.
Construction and Status of the Origami Module Prototype C. Irmler HEPHY Vienna.
Construction and Performance of a Double-Sided Silicon Detector Module using the Origami Concept C. Irmler, M. Friedl, M. Pernicka HEPHY Vienna.
Mounting Direction Water Cooler Best solution OK Risk of air bubbles in the system Heatsink Water channels Inlet Outlet.
M.Friedl, C.Irmler, M.Pernicka HEPHY Vienna
19 November 2009 Christian Irmler (HEPHY Vienna) APV25 and Origami Scheme 4 th Open Meeting of the Belle II Collaboration.
1 Denis Grondin – Sept.23 TH, 2010 Cooling & mechanics status CALICE Collaboration Casablanca at LPSC ECAL.
18 November 2010 Immanuel Gfall (HEPHY Vienna) SVD IR Mechanics 7 th B2GM.
The First Law of Thermodynamics
SVD Mechanics 21th B2GM Florian Buchsteiner (HEPHY Vienna)
Heat Transfer Equations For “thin walled” tubes, A i = A o.
18 November 2010 Immanuel Gfall (HEPHY Vienna) SVD Mechanics IDM.
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
7 th B2GM SVD Summary 19 November 2010 Markus Friedl (HEPHY Vienna)
APV25 for SuperBelle SVD M.Friedl HEPHY Vienna. 2Markus Friedl (HEPHY Vienna)11 Dec 2008 APV25 Developed for CMS by IC London and RAL (70k chips installed)
Origami Chip-on-Sensor Design: Progress and New Developments 19th September 2012 TWEPP 2012, C. Irmler (HEPHY Vienna) TWEPP 2012, Oxford University.
Collision Analysis SVD Meeting Markus Friedl (HEPHY Vienna) 18 June 2015.
R&D status of FPCCD VTX and its cooling system Yasuhiro Sugimoto for FPCCD VTX group 1.
Jochen Ebert, Uni Karlsruhe1 Powering via cooling pipes very first results.
1 R&D Status and plan for FPCCD VTX Yasuhiro Sugimoto
1 H. Pernegger/CERNIBL cooling review 15/5/2012 IBL Cooling Requirements H. Pernegger.
Construction and Test of the First Belle II SVD Ladder Implementing the Origami Chip-on-Sensor Design 29 Sept TWEPP 2015, C. Irmler (HEPHY Vienna)
The Belle II Silicon Vertex Detector Florian Buchsteiner (HEPHY Vienna)
LHCb VELO Meeting LHCb VELO Cooling System Bart Verlaat (NIKHEF) 25 February 2003.
J. Direito - M. Battistin – 28 th May 2010EN/CV/DC J. Direito, M. Battistin (EN/CV/DC) 28 th May 2010 Detector Cooling Project III Thermosiphon Workshop.
The Mechanical Structure for the SVD Upgrade
Solar Heating/Cooling/Dehumidifier Systems
SVD Mechanics Markus Friedl (HEPHY Vienna) BPAC, 26 October 2015.
11 June 2015 Thomas Bergauer (HEPHY Vienna) Belle II SVD beam Test SPS 2015 SPS users meeting.
R&D Status and plan for FPCCD VTX Yasuhiro Sugimoto
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Construction and Status of the Origami Module Prototype C. Irmler, M. Friedl HEPHY Vienna.
Update on Micro Channel Cooling Collaboration Meeting , G. Nüßle.
Mitglied der Helmholtz-Gemeinschaft Jörg Wolters, Michael Butzek Focused Cross Flow LBE Target for ESS 4th HPTW, Malmö, 3 May 2011.
CO 2 Controlling a 2-phase CO2 loop using a 2-phase accumulator
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH Design of the thermosiphon Test Facilities Thermosiphon Cooling Review A. MORAUX PH Dpt / DT Group CERN SEPTEMBER.
Aachen Status Report: CO 2 Cooling for the CMS Tracker at SLHC Lutz Feld, Waclaw Karpinski, Jennifer Merz and Michael Wlochal RWTH Aachen University, 1.
10 September 2010 Immanuel Gfall (HEPHY Vienna) Belle II SVD Upgrade, Mechanics and Cooling OEPG/FAKT Meeting 2010.
Origami and PA design 6 February 2012 Christian Irmler (HEPHY Vienna) 1 Common SVD-PXD Meeting.
Comments on ladder structure 5 Feb Toru Tsuboyama.
Technical Design for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
Ladder Mount R&D T. Tsuboyama (KEK) 2 Oct T. Tsuboyama (KEK) 2 Oct
Origami and Cooling 24th September 2012 C. Irmler (HEPHY Vienna) Joint PXD and SVD Meeting Göttingen.
25th April 2013 C. Irmler (HEPHY), Y. Onuki (IPMU) Ladder Assembly Procedure Belle II – New Collaborators Meeting.
7 February 2012 Annekathrin Frankenberger (HEPHY Vienna) Open CO 2 Cooling System at the beam test Belle II SVD-PXD Meeting.
MVD COOLING STATUS COOLING PLANT UPDATE: -ADDITION of the NEW CIRCUITS FOR GBT AND DC-DC Converter BOARDS IN THE COOLING PLANT -THERMAL STUDY OF GBT AND.
13 Januar 2011 Immanuel Gfall (HEPHY Vienna) Annekathrin Frankenberger (HEPHY Vienna) SVD Cooling Cooling Meeting Karlsuhe.
24 September 2012 Immanuel Gfall (HEPHY Vienna) SVD Status of Mechanics PXD-SVD Meeting Göttingen.
24 September 2012 Immanuel Gfall (HEPHY Vienna) Annekathrin Frankenberger (HEPHY Vienna) SVD Status of Mechanics PXD-SVD Meeting Göttingen.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
SVD Slow Control Markus Friedl (HEPHY Vienna) DAQ/SC Kickoff Meeting, 8 November 2012.
SVD Electronics Constraints
SVD Introduction Wetzlar SVD-PXD Meeting, 4 February 2013
Feedback on transfer line sizing and flow calculations for UT
Micro Vertex Detector of PANDA Status of Strip BARREL and DISC
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
Christoph Schwanda (HEPHY Vienna) For the Belle II SVD group
Cooling pipes and Space for Services
Optimized design for an sLHC Silicon tracker
CFD-Team Weekly Meeting - 8th March 2012
Aachen Status Report: CO2 Cooling for the CMS Tracker at SLHC
Comments to the SVD4 structure
C. Irmler, M. Friedl, M. Pernicka HEPHY Vienna
Presentation transcript:

27 January 2010 Immanuel Gfall (HEPHY Vienna) Belle II SVD Mechanics and Cooling DEPFET Meeting Prag

Belle II SVD Mechanics and Cooling 2Immanuel Gfall (HEPHY Vienna)27 January 2010 Origami Concept Thinned readout chips (APV25) on sensor Strips of bottom side are connected by flex fanouts wrapped around the edge All readout chips are aligned  single cooling pipe Shortest possible connections  high signal-to-noise ratio Total material budget: 0.58% X 0 3-layer kapton hybrid DSSD Single-layer fanoutsRohacell APV25 Cooling Pipe

Belle II SVD Mechanics and Cooling Mechanical Structure Composite sandwich rib design Gravitational sag <100 µm Sag is equal in horizontal and vertical sensor position 3Immanuel Gfall (HEPHY Vienna)27 January 2010 Composite ribs Sensor mounting points DSSD Origami Sensors Endring Mount

Belle II SVD Mechanics and Cooling Assembled Barrel 4Immanuel Gfall (HEPHY Vienna)27 January 2010 Cooling Loop Outlets Capillary Evaporators Layer 6,5,4 Endring Mounts

Belle II SVD Mechanics and Cooling Space Issue Forward Region Slanted sensor design strongly limits available space Cables density Hybridboards need space Coolingpipes space problem 5Immanuel Gfall (HEPHY Vienna)27 January 2010 Cooling pipe loops Ø Layer 4: 7.6 cm Ø Layer 5: 12.2 cm Ø Layer 6: 15.6 cm

Belle II SVD Mechanics and Cooling Thermal Conditions # of Origamis/LadderNumber of laddersNumber of APV25‘s Layer Layer Layer Immanuel Gfall (HEPHY Vienna)27 January 2010 Power dissipation/APV: 0.4 W 1 Origami sensor features 10 APV‘s Total Origami power dissipation: 368 W Total SVD power dissipation: 761 W 393 W dissipated at the endrings

Belle II SVD Mechanics and Cooling Observations Little power dissipation Heat distribution focused on small strips Cooling pipes are sufficient, no heatspreaders needed Heat transport is ensured by any solution (singlephase and dualphase) Relative SNR improvement of -8°C 7Immanuel Gfall (HEPHY Vienna)27 January 2010

Belle II SVD Mechanics and Cooling Requirements for Cooling the SVD Low temperature ~ -20°C Dry air / nitrogen environment Air / Gasflow through SVD not necessary for cooling Exchange of gas at a slow rate is welcome (< 1 m/s) Temperature stability Warm supplylines to avoid water condensation 8Immanuel Gfall (HEPHY Vienna)27 January 2010

Belle II SVD Mechanics and Cooling The CO 2 Solution Requirements are met by CO 2 Warm ~ +20°C CO 2 Radiationhard gas Low cost dualphase system Technology successfuly proven (LHCb-VELO) Existing experience from industrial solutions It is a „green“ solution 9Immanuel Gfall (HEPHY Vienna)27 January 2010

Belle II SVD Mechanics and Cooling The CO 2 Problems „Pressure Issue“ High pressure in supplylines (~70 bar) High pressure in evaporator (~20 bar) Pressurelines and connectors are tested to over 100 bar : no problem! Complex system requires skilled engineering and human resources 10Immanuel Gfall (HEPHY Vienna)27 January 2010

Belle II SVD Mechanics and Cooling Engineering Challenges Calculation of the capillary evaporator or finding/ building a suitable expansion valve Calculation of pressuredrop in the circuit Compensating pressure bending of the pipes Fitting the cooling circuit into the SVD volume Developing a monitoring and regulation system Subcooling the fluid state CO 2 at expansion valve 11Immanuel Gfall (HEPHY Vienna)27 January 2010

Belle II SVD Mechanics and Cooling Design Study Layer 6 12Immanuel Gfall (HEPHY Vienna)27 January 2010 Coolingloop Outlet (Detachable) Outlet Circular Line Evaporator (Dummy) Detachable Inlet Circular Line Source (Liquid) Drain (~70% Gas)

Belle II SVD Mechanics and Cooling Cooling Plant 13Immanuel Gfall (HEPHY Vienna)27 January 2010 Sanyo unit with 900 W output available Evaporating temperature adjustable between - 30°C and -5°C Small package outline (630x520x245 mm) Relatively cheap unit Several different units from CERN and Italy available but more expensive

Belle II SVD Mechanics and Cooling Outlook Obtaining a cooling unit and evaluating it Calculating pressure drop and thermodynamical parameters for the coolingcircuit Building the unit Testing Tuning 14Immanuel Gfall (HEPHY Vienna)27 January 2010