APPROVAL SHEET DESCRIPTION : 16 X CCD COLOR CAMERA SET MODEL NO. : ONZ - AN101 /151/102/152 ( NTSC) ONZ - AP101 /151/102/152 ( PAL ) ISSUED CHECKED APPROVED.

Slides:



Advertisements
Similar presentations
th Ave NE, Marysville, WA 98270, USA Robust Stabilized CO 2 Lasers with Line Tracker Access Laser Company where.
Advertisements

Available in Black and Silver The all-in-one camera.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Set the Camera Options  Resolution  Focus  Exposure  Zoom  Flash  Self-Timer/Remote Control.
Editing Process –Set up Decks, Monitors –Prepare Master Tape –Know operation of edit controller.
The Handling Camera1 Trainer Training The Handling Camera.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
Video Basics – Chapter 4 The Video Camera.
CAMERA MODULE & BOARD. ■ DNR (Digital Noise Reduction) By using the DSP chip applied to the DNR technology, the amount of low illuminance noise has been.
University of Tehran 1 Interface Design Serial Communications Omid Fatemi.
The Vision of a Leader Rapid Eye Plus Technical Training.
VIDEO/DC ↔ ELC All Menu value reset Return Camera default all value INIT & RESET State ICON display enable (1minute)‏1MIN ↔ OFF STATE DISPLAY Lens type.
QN = BQ403E One-Page B/W Quad Processor USER MANUAL.
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
RCD 510 Specification&Installation (RCD ~ ) For your best convenience QDIS CO., LTD -. MODEL: QVL – RCD510-V0 -. P/N : AD
OSD MANUAL FOR 700TVL CAMERA. ■ LENS You can select AUTO or MANUAL mode, depending on the connected lens type. AUTO(TYPE, MODE, SPEED) : Select Auto Iris.
Camera Remote Control Unit (AK-HRP150) Camera remote control unit AK-HRP150 is a camera controller for multi-purpose camera AK- HC900, AK-HC910 and AK-HC1500,
Digital Cameras. Image Capture  Images are captured by the image sensor, then stored in the camera in a memory device.  Sensors convert light into an.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
APPROVAL SHEET ISSUED CHECKED APPROVED DATE : 05. Jun. ‘02 REVISION No. 2.0 MESSRS. Receipt Stamp C&B Technology Inc. DESCRIPTION : CCD Color Board Camera.
APPROVAL SHEET ISSUED CHECKED APPROVED DATE : 31. May. ‘01 REVISION No. 1.0 MESSRS. Receipt Stamp C&B Technology Inc. DESCRIPTION : CCD Color Board Camera.
Analog Discovery Arbitrary Function Generator for Windows 7 by Mr
Lee Elliott Dec04. The New TK- WD310E(A) 1/3" digital image device with Wide Dynamic Range (WDR) Innovative 14-bit DSP High-speed, automatic 5-level exposure.
Comparison JVC TK-C9510E SLL1 vs. Samsung SCB-4000
Slide 1 Project 1 Task 2 T&N3311 PJ1 Information & Communications Technology HD in Telecommunications and Networking Task 2 Briefing The Design of a Computer.
Camera Basics Intro to TV Production. It’s like riding a bike… You can learn to operate a camera only by doing it.
RGB-LE CONVERTER Specification & Installation
WS50(Stratacache) Software updating guide (By Using USB)
Service Section Technical Training December 2005.
Your best partner for better driving Updated date : Model : RGB-LE-V3.1 / Product code : RB W164+RGB-LE Specification & Installation.
Programming 27x Optical 10x Digital Zoom Day/Night Camera Prosecutor Day / Night Windshield Mount Camera.
Inside the Digital Camera. Types of Digital Cameras Pocket CameraRangefinder SLR Like DSLR.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
AM-H676ER H.264 IP Speed Dome Camera Product Key Features: H.264 Main Level 3 Compression 960H 928*576 30fps PAL/NTSC 30fps ¼” SONY Super HAD.
AM-H676 H.264 IP Speed Dome Camera H.264 IP Speed Dome Camera Product Key Features: H.264 Main Level 3 Compression 960H 928*576 30fps ¼” SONY.
Introduction The Epson LCD projector is a highly versatile presentation tool. The projector can utilize up to two computer sources, and up to three video.
FEATURES USER’S MANUAL COLOR BOX CAMERA SDB-BAW SDB-BAW/T 1/3 " SONY 960H Dual Scan CCD High Resolution of 800TV Lines Min. Illumination of Lux at.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
All rights reserved by Cynix, Inc. 1MAR. 2, 2009 Product Specification.
Iris Control SDI-DC212IRV HD-SDI IR DOME CAMERA USER’S MANUAL FEATURES SPECIFICATIONS MEMO 1/3” 2.1Megapixel Progressive Panasonic CMOS
HD-SDI COLOR IR LED CAMERA
Highly configurable video camera with 12-stops dynamic range and Dual Pixel CMOS AF. Compact and lightweight, this highly adaptable video camera with Dual.
Technical Specifications
HD-SDI DOME CAMERA SDI-DC221 SPECIFICATIONS MEMO USER’S MANUAL
V2867NVD 100mm Vandal-Resistant Dome Camera Features ACCESSORY
VCQ-F/P313HN/HP COLOR MINIATURE CAMERA Features Specifications
960H(700 TVL) PTZ Speed Dome Camera (X28E with WDR)
Night Scout TVI (30X HD-TVI IR PTZ)
HD-SDI IR BULLET CAMERA
VCQ-F/P332WN/WP COLOR MINIATURE CAMERA Features Specifications
COLOR DOME CAMERA SDD-D425V SPECIFICATIONS MEMO USER’S MANUAL FEATURES
HD-SDI IR HOUSING CAMERA
HD-SDI White LED Ball Camera
TK-T8101WPR New line with True Day/Night and built-in IR LED Camera
HD-SDI COLOR IR LED CAMERA
Using a Camera.
Cameras and Lighting Ms. Murphy.
McCrometer Nano Board Test Procedure
DOME OUTDOOR ADVANCED IR LED DOME CAMERA ADVANCED IR BULLET CAMERA
OUTDOOR OUTDOOR ADVANCED IR LED OUTDOOR CAMERA
BULLET OUTDOOR ADVANCED IR LED BULLET CAMERA ADVANCED IR BULLET CAMERA
HCV-HD 1.0MP AHD Camera Features:
OUTDOOR OUTDOOR ADVANCED IR LED OUTDOOR CAMERA
HD-SDI IR BULLET CAMERA
OUTDOOR OUTDOOR ADVANCED IR LED OUTDOOR CAMERA
DOME OUTDOOR ADVANCED IR LED DOME CAMERA ADVANCED IR BULLET CAMERA
EX-SDI 2.0 ADVANCED IR LED DOME CAMERA 1/2.8 inch SONY CMOS (IMX-291)
Presentation transcript:

APPROVAL SHEET DESCRIPTION : 16 X CCD COLOR CAMERA SET MODEL NO. : ONZ - AN101 /151/102/152 ( NTSC) ONZ - AP101 /151/102/152 ( PAL ) ISSUED CHECKED APPROVED DATE : 11. Jul. ‘00 REVISION No. 1.0 MESSRS. Receipt Stamp ONIX SYSTEM INC.

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. CCD COLOR CAMERA SPECIFICATIONS ONZ - AN101, 151, AP101, 151 : Control through RS-232 Signal ( TTL Level ) ONZ - AN102, 152 AP102, 152 : Control through RS-422/485 Signal CONTENTS 1/11 1. SPECIFICATIONS MEASUREMENT SPECIFICATIONS EXTERNAL CONTROL SPECIFICATIONS ENVIRONMENT CONDITION AND TEST LAYOUT OF PLUG INTERFACE (RS-232C) INTERFACE(RS-422/485) RECOMMENDED CIRCUIT FOR LOCAL CONTROLS LENS TEST CONDITION APPEARANCE PACKING METHOD PAGE

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 1. SPECIFICATIONS Signal SystemNTSC ( ONZ - AN101/102 )PAL ( ONZ - AP101/102 ) Scanning System2 : 1 Interlace Scanning Frequency ( H ) KHz KHz Hz50 Hz Image Sensor1 / 4 Inch Solid State Interline CCD Image Sensor Total Pixels No. Effective Pixels No. Scanning Frequency ( V ) REMARKS 811 (H) X 508 (V) 410K795 (H) X 596 (V) 470K 768 (H) X 494 (V) 380K752 (H) X 582 (V) 440K Signal SystemNTSC ( ONZ - AN151/152 )PAL ( ONZ - AP151/152 ) Scanning System2 : 1 Interlace Scanning Frequency ( H ) KHz KHz Hz50 Hz Image Sensor1 / 4 Inch Solid State Interline CCD Image Sensor Total Pixels No. Effective Pixels No. Scanning Frequency ( V ) REMARKS 537 (H) X 505 (V) 270K537 (H) X 597 (V) 320K 510 (H) X 492 (V) 250K500 (H) X 582 (V) 290K 1) Lens F1.4 ~ 2.8, f = 4.0 ~ 64.0 mm, x16 Zoom Video Auto Focus Angle of View H : 47 。 (WIDE), 3 。 (TELE) High Durability Zoom Lens a) Zoom Durability More than 500k at Room Temperature ( See Page. 6. ) b) Focus Durability More than 500k at Room Temperature ( See Page. 6. ) c) Iris Durability More than 500k at Room Temperature ( See Page. 6. ) 2) Focus Length ∞ ~ 1.0m (Tele) ~ 0.01m (Wide) 3) Signal Process Digital Signal Process 4) Sync System(Auto) Internal / External sync ( Line Lock) 5) Camera Function Control through RS-232 Signal ( TTL Level ) : CNB-AN101,151,AP101,151 Control through RS-422/485 Signal : CNB-AN102,152,AP102,152 a) Optical Zoom TELE ~ WIDE (Zoom Speed : 3.6 sec / 6 sec ) b) Digital Zoom Off / On ( ~ 8 times ) c) Video Focus Auto / Manual ( NEAR ~ FAR ) / Push Auto (a) Manual Mode Zoom Start Zoom Stop Manual Manual ( AF Action is activated for a moment before focus stops ) “ Bold : Default Mode ” 2/11

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. d) White Balance Auto / Indoor / Outdoor / Push Auto / Manual ( R&B Gain Level UP/Down ) Special ( R or B Gain Level Control ) e) Shutter Speed Auto/ Manual (1/60 ~ 1/ ( NTSC) / 1/50 ~ 1/10000 (PAL) ) f) Iris Control Auto / Manual ( Manual Iris Level : UP ~ Down) g) Gain Control Auto / Manual ( Auto Gain Control : UP ~ Down) h) Sharpness Manual ( Sharpness UP ~ Down ) i) Brightness Manual ( Brightness UD ~ Down ) j) Negative Off / On ( Negative Level UP ~ DOWN ) k) OSD Function On / Off (See an Annexed Document “ APPENDIX 1 ” ) l) Flickerless Off / On ( 1 / 100 sec Shutter Set (NTSC) / 1 / 120 sec Shutter Set (PAL) ) m) Back Light Off / On/ Auto n) Position Preset 64 Mode Set / Move ( Store with Internal EEPROM ) (a) Zoom Trace Preset Mode : MF Trace * In case of memory ( EX. Memory Point : ) WIDE TELE ×1×16 ×32(Opt.) (Digi.) 3.6 sec 1 sec (b) Zoom Trace Preset Mode : MF NO-Trace * In case of preset WIDE TELE ×1×16 ×32(Opt.) (Digi.) 1.6 sec Instant 6) Video Output Level NTSC Video Level Sync Level ± 0.07V ( 100 ± 10 IRE) ± 0.035V ( 40 ± 10 IRE) Burst Level0.286 ± 0.035V ( 40 ± 10 IRE) 700 ± 70 mV 300 ± 35 mV PAL Video Level Sync Level Burst Level 3/11

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 7) Color Reproduction NTSC Amplitude ( % ) Phase ( 。 ) 100 %(Base) 180 。 (Base) REDBLUEYELLOWBURSTCOLOR 200 ± 40 % 103 ± 20 。 PAL Amplitude ( % ) Phase ( 。 ) 100 %(Base) 135 。 (Base) 130 ± 40 % 345 ± 20 。 115 ± 40 % 170 ± 20 。 200 ± 40 % 103 ± 20 。 130 ± 40 % 345 ± 20 。 115 ± 40 % 170 ± 20 。 8) Horizontal Resolution More than 480 Lines ( High Resolution ) More than 380 Lines ( Normal Resolution ) 9) Luminance S/N More than 48 dB 10) Sensitivity Typ. 1Lux ---- At signal Level 30 IRE ( LENS-F : F = 1.4 ( WIDE ) AGC Gain : Max 11) Supplied Voltage 9.0 V ~ 15.0 V ( Recommendation 12.0 V ± 0.5 V ) 12) Supplied Current 210 mA ( Steady-state ) 350 mA ( Max ) Under the zooming and focusing Operation 13) Power consumption 4.3 W (Max) 14) Dimensions 58.0(W) × 59.8 (H) × 101.2(D) mm ( Except Connector ) 15) Weight 330 g ( Approx. ) 16) Appearance / Dimensions See Attached Page ) Body Color Black 18) Packing Method See Attached Page ) Optional Accessories 2. MEASUREMENT SPECIFICATIONS * Standard Measurement Condition and Measurement Procedure See an Annexed Document “ APPENDIX 2 ” 3. EXTERNAL CONTROL SPECIFICATIONS * External Control Using RS-232C ( Command List ) See an Annexed Document “ APPENDIX 3 ” 4/11

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 1) Operating Condition Temperature -10 。 C ~ 50 。 C ( Recommendation : -5 。 C ~ 40 。 C ) Humidity 10 % ∼ 85 % 2) Storage Condition Temperature -20 。 C ~ 60 。 C Humidity 0 % ∼ 90 % 3) High Temperature storage Test Leaving the packed at Temperature of 60 。 C for 72 Hours, and then after leaving it at Normal Temperature for 8 Hours, there should be no Problem in Performance. 4) Low Temperature storage Test Leaving the packed at Temperature of -20 。 C for 72 Hours, and then after leaving it at Normal Temperature for 8 Hours, there should be no Problem in Performance. 4. ENVIRONMENT CONDITION AND TEST 5/11 5. LAYOUT OF PLUG ( REAR PANNEL)

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 6. INTERFACE ( RS -232C TTL : ONZ-AN101,151,AP101,151 ) 1-1) Pin Assignment ( 6 Pin Circle Connector ) Key NAME PIN No I/O Input Note Input 1) Pin Diagram ( 6 Pin Circle Connector ) : Rear View W GND Output Input Green White Brown Yellow Black Red * is the color of the cable. ( If it offered ) GND * Color RD(For RS-232C) TD(For RS- 232C) CMOS Level 5V ( Low : Max 0.8V, High : Min 3.7V ) Line IN EX. FV ( Negative. 5 Vp-p ) Frame GND 2. RD 3. TD 4. DTR 5. Signal GND 6. DSR 7. RTS 8. CTS 9. RI A) RS-232C D-Sub Connector 2) PC Interface RD1 TD2 6/11 NAME

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 7. INTERFACE (RS - 422/485 : ONZ-AN102,152,AP102,152 ) 1-1) Pin Assignment ( 6 Pin Circle Connector ) T+ NAME PIN No I/O Input Note 1) Pin Diagram ( 6 Pin Circle Connector ) : Rear View W GND Output Input Green White Brown Yellow Black Red * is the color of the cable. ( If it offered ) T - * Color R+ R - ) Line IN EX. FV ( Negative. 5 Vp-p ) 2) PC Interface ( RS-422 Communication) Input Output R +1 R -2 T +3 T -4 Tx+ Tx- Rx- Rx+ TD RD A) RS-232C TO RS-422 Converter 1. Frame GND 2. RD 3. TD 4. DTR 5. Signal GND 6. DSR 7. RTS 8. CTS 9. RI B) RS-232C D-Sub Connector 7/11 NAME

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 2) Line In Pulse ( EX. FV) Min : 200 nsec 60 Hz ± 0.25 Hz ( NTSC ) 50 Hz ± 0.25 Hz ( PAL) 5 V 0 V A) Pulse- Signal Spec of EX.FV 1) KEY Function(CNB-AN101/151/AP101/151) 8. RECOMMENDED CIRCUIT FOR LOCAL CONTROLS 8/11 POWER ON/OFF 6.8K8.2K12K18K33K68K180K TELE(+) 0.01uF KEY3 MENUWIDE(-) A/M PUSH AUTO NEGA ON/OFF NEAR(+)FAR(-) : WIRE REMOTE CONTROL KEY FUNCTION

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 9/11 9. LENS TEST CONDITION 1) Zoom 2) Focus 1.5sec 1 Cycle 3 ) Auto Iris 1.5sec 3 sec TELE WIDE 1 sec pause 1 Cycle NEAR FAR 1V pause 1V 1 Cycle OPEN CLOSE RESET

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 10. APPEARANCE 10/11

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 11. PACKING METHOD 11/11

APPENDIX 1 ONZ - AN101 /151/102/152 ( NTSC) ONZ - AN101 /151/102/152 ( PAL) DATE : 11. Jul. ‘00 REVISION No. 1.0 MODEL : OSD(On Screen Display) ONIX SYSTEM INC.

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 1. OSD(On Screen Display ) FORMAT 2) DESCRIPTION 1 OSD FormatDESCRIPTIONREMARKS 2 FUNCTION Focus Mode Non displayFocus Auto Mode Focus Manual Mode Mirror Mode Mirror Mode Off 1) OSD DISPLAY POSITION Non display X10000 ID 255 WAIT W T X Mirror Mode On 3 Back Light Back Light OFF Back Light ON Non display 4 White Balance AUTO WBC MODE Push Auto White Balance: In this mode “Push Key” pressed,the white point traced automatically(PWB Auto Mode), “Push key” released, the white point preserved currently (PWB Manual Mode). A Auto Back Light ON 1/5

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. * The OSDs of 1,2,3,4,5,7,8 disappear 5 sec later. But 6 can be displayed continuously by ID On/Off Key Action ( controlled by PC command Key). OSD FormatDESCRIPTIONREMARKSFUNCTION 5Shutter Speed Normal Shutter ( NTSC:1 / 60 PAL:1 / 50 ) 1 / / variable steps. (Can be set to 8 steps by manufacture Option) Non display 6CAMERA ID After input the Identification Number to each camera, Multi-point control is available (PC Control ) ( 000 ∼ 255 ). 7 WAIT MODEWAIT Indicates the camera stand-by mode until the camera power turns ON. 8 ZOOM DISPLAY W W T X10 T X20 ; In case of 16X Zoom; Optical Zoom only mode ; (Current Zoom :10X) ; In case of 32X Zoom ; Digital Zoom 2X mode ; (Current Zoom : 20X) WT X100 ; In case of 128X Zoom ;Digital Zoom 8X mode ; (Current Zoom : 100X ) Sharpness Adjustment Mode DISPLAY Brightness Adjustment Mode DISPLAY X10 X34 2/5

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 2. MENU DESCRIPTIONS ( ENGLISH ) 1) MENU FORMAT MENU 1 IMAGE MIRROR OFF (ON) 2 NEG / POS POS (NEG) 3 COLOR ON (OFF) 4 WB CONTROL AUTO (PUSH AUTO) 5 SHUTTER 1/ CAMERA ID 123 MENU 7 ZOOM START X1 8 ZOOM STOP X128 9 BRIGHTNESS SHARPNESS FOCUS AUTO (PUSH AUTO) 12 INIT SET OFF (ON) END TELE BLC WIDE MENU (+) (-) (SET) 3/5

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 3 ) MENU DESCRIPTION (1) IMAGE MIRROR When IMAGE MIRROR is ON state, The image displays in the opposite direction. (3) COLOR ON : Color Mode, OFF : B / W (Monochrome Mode). (2) NEG/POS Use to change NEGATIVE and POSITIVE mode. ON : Negative Mode, OFF : Positive Mode. (7) ZOOM START Wide Zooming Area Start point allocation (1 ~128). (4) WB CONTROL Use to change White Balance Mode. - AUTO : WB Range 2800 。 K ∼ 8000 。 K. - PUSH AUTO : In this Mode you can adjust White point by using PUSH AUTO Key. (5) SHUTTER Use to change the Shutter Speed. At this time, AE mode acts automatically ( 28/8 steps control is available ). (6) CAMERA ID Each Identification number can be assigned to each camera. And ID NOs can be displayed on Monitor to confirm each camera. ( 000 ~ 255 : total numbers of ID are 256 ). (8) ZOOM STOP Tele Zooming Area End point allocation (1 ~128). (9) BRIGHTNESS Use to change the brightness level of scene ( 0 ~ 48 ). (10) SHARPNESS Use to change the contour of scene ( 0 ~ 15 ). (11) FOCUS Use to change Focus Mode. - AUTO : Focusing acts Automatically - MANUAL : Focusing is controlled by Far and Near Keys. - PUSH AUTO : Auto Focusing is activated for a moment (when Push Auto Key is pressed) and stops. (12) INIT SET Turn the initial mode ON, the changed data are renewed to manufacturer settings. (The data are initialized to its shipping condition ) 2) Using MENU (1) Menu Mode : In order to display the MENU on the screen, Press the MENU key. If you keep pressing MENU over 2 seconds, OSD will be off. Menu mode will be displayed again once Menu is pressed. (2) Menu Item selection Mode: Position Hand Mark to each ITEM you want to change by using Wide and Tele Keys. Press the BLC(SET) button. (3) Menu Data Change Mode: Press the TELE and WIDE key.Then the right side of selected ITEM will blink and the values can be changed by using Tele and Wide keys. Press the BLC(SET) button. (4) Press the BLC(SET) key again to return to Mode(2). (5) To escape from Menu Mode, Press Menu key again in Mode(2). Remarks : BLC(SET) Key Switches Menu Item selection Mode(2) and Menu Data change Mode(3). 4/5

APPENDIX 2 ONZ - AN101 /151/102/152 ( NTSC) ONZ - VP101 /151/102/152 ( PAL) DATE : 11. Jul. ‘00 REVISION No. 1.0 MODEL : Measurement Specifications ONIX SYSTEM INC.

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 1. MEASUREMENT CONDITIONS 1) Standard Measurement Conditions Supplied Voltage DC 12V ± 0.5 V Ambient Temperature 23 ℃ Humidity 60 % RH Measurement Fixture Video output, DC input, RS-232C level Convert ( 5Vpp -> 12Vpp) Power Supply 12V ± 0.5 V Color Monitor CMM , Shibasoku or Equivalent Monochrome Monitor More than 800 TV Lines Horizontal Resolution Waveform Monitor / Vector Scope 1720A, Tektronix ( NTSC / EIA ) or Equivalent 1730A, Tektronix ( PAL / CCIR ) or Equivalent S / N ( Signal to Noise )Meter VN31AX, Shibasoku ( NTSC/PAL/EIA/CCIR ) or Equivalent Illumination Meter / Color Temperature Meter XY-1 / CL-100, Minolta Camera or Equivalent Light Box Dai Nippon Printing Co. - Color Temperature 3200 。 K ± 100 。 K - Illumination More than 2000 Lux Test Charts ( Transparent Chart ) Color Bar Chart, Dai Nippon Printing Co. Gray Scale Chart, Dai Nippon Printing Co. ( Gamma 0.45 ) Resolution Chart, Dai Nippon Printing Co. ( Reflective Chart ) Gray Scale Chart, Murakami Color Research Lab Light Source Halogen Lamp ( with Dimmer Switch ) - Color Temperature 3200 。 K ± 100 。 K - Illumination Variable with Dimmer Color Temperature Filter LB 140, Hoya or Kenko or Equivalent ( Color Temperature Conversion Filter ) Adjustment PC With Serial Port 1 or 2 RS-232C Cable Each Terminal Connector ( D-Sub 9 Pin ) 2. Measuring System 1) System 1. Measurement Fixture Light Box Color Monitor Monochrome Monitor Waveform / Vector scope FFC PC with Serial Port 2) System 2. Light Source Same as above System 1. Camera Reflective Chart EQUIPMENTSEQUIPMENTS 1/5

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 2. MEASUREMENT PROCEDURE 1. VIDEO OUPUT LEVEL TEST CONDITIONS MEASURING SYSTEM Refer to “ 1. MEASUREMENT CONDITIONS “ System 1. PROCEDURE : 1. Shoot the gray scale chart, and Zoom WIDE or TELE to fit a scene of monitor fully by PC. 2. Measure the video output level on the waveform monitor ( Before the above measurement, Measure the SYNC and BURST level ) A B C ( Fig 1. ) Video Output Waveform SPECIFICATION : NTSC Video Level A Sync Level B 100 ± 10 IRE 40 ± 5 IRE Burst Level C40 ± 5 IRE 700 ± 70 mV 300 ± 35 mV PAL Video Level A Sync Level B Burst Level C 2/5

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 2. COLOR REPRODUCTION TEST CONDITIONS MEASURING SYSTEM Refer to “ 1. MEASUREMENT CONDITIONS “ System 1. PROCEDURE : 1. Shoot the color bar chart, and Zoom WIDE or TELE to fit a scene of monitor fully by PC. 2. Measure the color amplitude and color phase on the vector scope of Red,Blue,Yellow. ( Before the above measurement, Adjust the burst amplitude and phase on the vectorscope so that the burst level becomes 100% and its phase becomes 180 。 (NTSC) (135 。 PAL) ( Fig 2. ) Video Output Waveform SPECIFICATION : NTSC Amplitude ( % ) Phase ( 。 ) ( Fig 3. ) Video Output Color Vector 100 % 180 。 REDBLUEYELLOWBURSTCOLOR 200 ± 40 % 103 ± 20 。 PAL Amplitude ( % ) Phase ( 。 ) 100 % 135 。 130 ± 40 % 345 ± 20 。 115 ± 40 % 170 ± 20 。 200 ± 40 % 103 ± 20 。 130 ± 40 % 345 ± 20 。 115 ± 40 % 170 ± 20 。 3/5

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 3. LUMINANCE S / N TEST CONDITIONS MEASURING SYSTEM Refer to “ 1. MEASUREMENT CONDITIONS “ System 1. PROCEDURE : 1. Shoot the light box, and zoom WIDE or TELE to fit a scene of monitor fully by PC. 2. The noise meter settings are ; Input level : Preset High Pass Filter : 100KHz Low Pass Filter : 4.2 MHz Sub-carrier Trap : On Weighting : On Sag & Hue Comp. : Optimum 3. Measure the maximum S/N on the noise meter. SPECIFICATION : NTSC : More than 48 dB PAL : More than 48 dB 4. HORIZONTAL RESOLUTION TEST CONDITIONS MEASURING SYSTEM Refer to “ 1. MEASUREMENT CONDITIONS “ System 1. PROCEDURE : 1. Shoot the resolution chart, and Zoom WIDE or TELE to fit a scene of monitor fully by PC. 2. Adjust the brightness and contrast of the B/W monitor so that each steps of gray scale part can be observed. 3. Change the scan size of monitor to underscan. 4. The reference arrows on the resolution chart are positioned at the edge of the underscanned picture. 5. Change the scan size of monitor from underscan to overscan. 6. Measure the maximum horizontal resolution on the picture. SPECIFICATION : More than 480 TV Lines ( High Resolution) More than 380 TV Lines ( Normal Resolution) 4/5

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 5. LOW LUMINANCE SENSITIVITY TEST CONDITIONS MEASURING SYSTEM Refer to “ 1. MEASUREMENT CONDITIONS “ System 2. PROCEDUTE : 1. Shoot the gray scale chart ( reflective ), and zoom WIDE fully by PC. 2. Adjust the brightness of the light source using the dimmer switch so that the white peak level of the chart becomes 30 IRE ( NTSC ) ( 210 mV,PAL ) on the waveform monitor. 3. Measure the level of illumination using the illumination meter. SPECIFICATION : 5/5 NTSC (HI) : 1 Lux ( 30 IRE ) PAL (HI) : 1 Lux ( 210 mV ) NTSC (Normal) : 0.5 Lux ( 30 IRE ) PAL (Normal) : 0.5 Lux ( 210 mV )

APPENDIX 2 DATE : 14. JULY. ‘00 REVISION No. 1.1 RS - 232C Communication Protocol ONIX SYSTEM INC. ONZ - VN100 /150 ( NTSC ) ONZ - VN101 /151 ( NTSC ) ONZ - VN102 /152 ( NTSC ) ONZ - VP100 /150 ( PAL ) ONZ - VP101 /151 ( PAL ) ONZ - VP102 /152 ( PAL ) MODEL :

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 1. Communication Format 2) The communication data format from PC to Camera 1 command consists of 11 codes and The data of total 11 bytes are transmitted from PC to camera. TOTAL 11 ASCII CODES. (b) Description ; 1’ST CODE : START CODE 2’ND CODE : THE HIGH CHARACTER OF CAMERA ID 3’RD CODE : THE LOW CHARACTER OF CAMERAI ID 4’TH CODE : COMMAND High 5’TH CODE : COMMAND Low 6’TH CODE : DATA 4 7’TH CODE : DATA 3 8’TH CODE : DATA 2 9’TH CODE : DATA 1 10’TH CODE : Check Sum High 11’TH CODE : Check Sum Low (a) Format ; 3) The communication data format from Camera to PC (Echo back data format ) ; The data of total 11 bytes are transmitted from Camera to PC. * TOTAL 11 ASCII 1) Connection Conditions ; Data Length 1 Byte = 1code ( 8 Bit ) Stop Bit 1 Bit Parity Bit None Baud rate 9,600 bps First last *IDHIDLCHCLD4D3D2D1C.SHC.SL (b) Description ; 1’ST CODE : START CODE 2’ND CODE : DATA 8 ( ID Code does not affect communication now) 3’RD CODE : DATA 7 ( ID Code does not affect communication now) 4’TH CODE : DATA 6 5’TH CODE : DATA 5 6’TH CODE : DATA 4 7’TH CODE : DATA 3 8’TH CODE : DATA 2 9’TH CODE : DATA 1 10’TH CODE : Check Sum High 11’TH CODE : Check Sum Low (a) Format ; First last *IDHIDLCHCLD4D3D2D1C.SHC.SL * Check Sum Method: ADD data1 to data 9 without carry. * If it becomes 3A as result of checksum data, It needs to be changed to ASC Ⅱ code [ ‘3’ ‘A’] Communication between the microcomputer of the camera and the PC is available by using the RS - 232C. The microcomputer receives each control command given by the PC through RXD INPUT TERMINAL and it echoes back to the PC through TXD OUTPUT TERMINAL 1/10

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 4) Communication Flow 2/10 start Send command (11codes) Are echo back data transmitted from camera ? Delay 20 ms Command transmission is ok ! Send next command Camera returns echo back data after execution of command from PC, So, in case of “ Internal Zoom Tracking PRESET Moving control command “ Echo back data can be delayed to several seconds. The minimum delay time between command and echo back data is 1 Milli- second. NO END YES 4) Miscellaneous for Communication * When transmitting 11 code of command, keep 2 Milli-seconds of waiting time between codes. * If command transmission is stopped after 3 code only, camera waits for the remain 8 codes continuously. At that moment, If new command,starting from ‘ * ’ (Start code ) is transmitted to camera, the previous 3 codes are ignored ! * IF echo back codes are error, there can be some troubles in communication line or data receiving timing. On software, you can send command again ! * About echo back : After 1 command, you need to wait for echo back data from camera for Transmission confirmation and next command transmission. But 1 more command transmission is possible before echo back data 20 milli second after first transmission.

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 2. RS - 232C Communication Commands : ‘X’ indicates don’t care code and “YY” indicates checksum 1) Camera RESET Reset the micro controller ( u-COM ) of Camera. 2) Camera ID Display ON/OFF control Switch the display of camera ID (ON/OFF). 3) CAM ID READ. ZZ : Camera ID 4) CAM ID CHANGE ; Change the data of CAM_ID to “ NEW_C_ID “. 5) Key Action ; See Page 10 Key action can be activated by this command. *XX75ZZXXYY ZZ : Key CODE Caution ; When you want to stop key action, send this command again by using “KC_STOP “. KEY CODE : Refer to 10-3.( Key Code Table ) for desired key action selection. *XX71XXXXYY *XX7201XXYY *XX7200XXYY ; ID ON ; ID OFF *XX73XXXXYY *XX74ZZXXYY ZZ : NEW ID CODE 6) Camera Power ON/Off Turn on the power of Camera. *XX760ZXXYY Z(1) : Power On Z(0) : Power Off 3/10 *XXZZXXXXYY :Return data 7) Function OSD Display Mode RD *XX79XXXXYY Read the Function OSD Display Mode of the camera *0ZXXXXXXYY ;return data Return Data : Z(0) : “ Function OSD ON” mode. : All osd display is enabled Z(1) : “ Function OSD OFF” mode : Excluding Menu osd display,All osd display is disabled. 8) Function OSD Display Mode Change *XX7A0ZXXYY Change the Function OSD Display Mode of the camera Z(0) : The Function OSD Display Mode is changed to “ Function OSD ON” mode. Z(1) : The Function OSD Display Mode is changed to “ Function OSD OFF” mode.

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 10) Camera Read Command of Digital Effect status *XX7EXXXXYY Read the current Digital Effect status of the Camera. The return data is “DEFT_Status”.  Construction of DEFT_Status data *0ZXXXXXXYY ;RETURN DATA Z(0) : NO DIGITAL EFFECT IS ACTIVATED Z(1) : WIDE(Cinema effect) ON Z(2) : ART ON Z(3) : Mirror ON, Z(4) : Nega effect on. Z(5) : COLOR OFF. Z(6) : MOSAIC ON. 11) Read the Exposure Mode *XX80XXXXYY Read the current Exposure Mode of the Camera. The return data is “AE MODE”. *0ZXXXXXXYY ;return data Z(0) : AUTO Exposure mode Z(1) : SHUTTER Manual mode. Z(2) : IRIS Manual mode. Z(3) : AGC Manual mode Z(4) : SHUTTER / IRIS / AGC All Manual mode 12) Exposure Mode Set Command *XX810ZXXYY Set the mode of Exposure according to “AE Mode” Z(0) : AUTO Exposure mode Z(1) : SHUTTER Manual mode. Z(2) : IRIS Manual mode. Z(3) : AGC Manual mode Z(4) : SHUTTER / IRIS / AGC All Manual mode 4/10 9) CAMERA status Read Command *XX7C0ZXXYY Read the current status of the Camera. *0RXXXXXXYY(RETURN DATA) Z(0) : Focus Mode READ --> R (0) : Focus Auto R(1) :Focus Manual Z(1) : Camera ID Display ON mode, --> R (0) : Camera ID Display OFF R(1) :DISPLAY ON Z(3) : BACKLIGHT ON state, --> R (0) : BACKLIGHT OFF R(1): Backlight On Z(4) : FLICKERLESS ON state, --> R (0) : FLICKERLESS OFF R(1): Flickerless on Z(8) : Auto BLC Mode, --> R (0) : Auto BLC Off Mode R(1): Auto BLC On Mode

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 13) BACKLIGHT Level Read *XX83XXXXYY Read the current BACKLIGHT level of Camera. *XXZZXXXXYY ;return Data ZZ : BACKLIGHT level. (data range 00 ~FF hex) 16) SHUTTER Speed Setting *XX86ZZXXYY Set the shutter speed with the “shutter counter”. ZZ :shutter counter 14) BACKLIGHT Level Adjust *XX84ZZXXYY Adjust the current BACKLIGHT level of Camera. ZZ: BACKLIGHT level. (data range 00 ~FF hex) 15) SHUTTER Speed counter read *XX850000YY Set the shutter speed with the “shutter counter”. *XX85ZZ00YY ;return data ZZ : shutter counter 00 : 1/60 01:1/125 02:1/250 03:1/ : 1/250 05:1/300 06:1/350 07:1/ : 1/450 09:1/500 10:1/600 11:1/ : 1/800 13:1/900 14:1/ :1/ : 1/ :1/ :1/ :1/ : 1/ :1/ :1/ :1/ : 1/ :1/ :1/ :1/ ) AGC Level Setting *XX87ZZXXYY Set the AGC Level with the AGC data. ZZ: AGC data 00(Minimum AGC Level) ~ FF Hex (Maximum AGC Level) 18) Read the current BRIGHTNESS data *XX88XXXXYY Read the current BRIGHTNESS data of the Camera. *XXZZXXXXYY ;return data The return data is “Brightness”. ZZ : 00(Minimum Brightness level) ~ 60 Hex (Maximum Brightness Level) 19) Read the IRIS control data *XX89XXXXYY *XXZZXXXXYY ;return data ZZ : IRIS Control Level (data range 00 ~FF hex) 5/10

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 20) IRIS Level Setting *XX8AZZXXYY Set the IRIS OPEN Level ZZ : IRIS control level (data range 00 ~FF hex) 21) Read the AGC control data *XX8B0000YY *XXZZ0000YY ;return data ZZ : Current AGC Control level (data range 00 ~FF hex) 22) IRIS Area Weighting Value Read *XX8EXXXXYY Read the current weighting value of Iris area. *XXABXXXXYY ;return data A:Region 1 weight data B:Region 2 weight data 24) FLICKERLESS Mode ON/OFF Setting *XX900ZXXYY Z(1) : Flickerless Mode Active Z(0) : Flickerless Mode inactive 6/10 23) IRIS Area Weighting Value Write *XX8FXXXXYY Read the current weighting value of Iris area. A:Region 1 weight data B:Region 2 weight data 25) BRIGHTNESS Data Setting *XX91ZZXXYY ZZ : Brightness level desired (data range 00 ~ 60 hex) 26) Read the White Balance Mode *XXB1XXXXYY Read the current White Balance Mode of the Camera. *XX0ZXXXXYY ;return data Z(0) : Auto Mode Z(1) : Special Z(2) : indoor Z(3) : outdoor Z(4) : Manual Z(5) : Push Auto 27) White Balance Mode Set Command *XXB20ZXXYY Set the mode of White Balance of the camera. Z(0) : Auto Mode Z(1) : Special Z(2) : indoor Z(3) : outdoor Z(4) : Manual Z(5) : Push Auto 28) Read the current MANUAL White Balance Mode data *XXB3XXXXYY *XXB3ZZXXYY ;return data ZZ : (data range 00 ~60 hex) R1 R2

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 29) MANUAL White Balance Mode MWB_CTL data Setting *XXB4ZZXXYY ZZ : (data range 00 ~60 hex) 30) Read the current SHARPNESS data *XXB5XXXXYY *XXB50ZXXYY ;return data Z : “Sharpness Data” Data value range 0 ~ F 32) Read the RED Adjust data at the SPECIAL White Balance Mode *XXB7XXXXYY *XXZZXXXXYY ;return data ZZ : Red adjust data (data range 00 ~ FF hex) 33) Read the BLUE Adjust data at the SPECIAL White Balance Mode data *XXB8XXXXYY *XXB8ZZXXYY ;return data ZZ : Blue adjust data. (data range 00 ~ FF hex) 34) SPECIAL White Balance Mode RED adjust data Setting *XXB9ZZXXYY ZZ : Red adjust data (data range 00 ~FF hex) 31) SHARPNESS data adjust *XXB60ZXXYY Z : “Sharpness Data” Data value range 0 ~ F 7/10 35) SPECIAL White Balance Mode BLUE adjust data Setting *XXBAZZXXYY ZZ : Blue adjust data (data range 00 ~FF hex) 36) Zoom Lens Position Read *XXC0XXXXYY *XX0ABCDEYY ;return data A : ZOOM POSITION HIGH BC : ZOOM POSITION LOW DE : DIGITAL ZOOM POSITION * zoom position range ( 00 ~ 42F Hex) * Digital zoom position range ( 00 ~ E0 Hex ) * : This command is used For Zoom Position setting In external PRESET mode. ABCDE is expressed in Hex data 37) Focus Lens Position Read *XXC1XXXXYY *XX0ABCXXYY A : FOCUS POSITION HIGH BC : FOCUS POSITION LOW * focus position range ( 3F ~ 315 Hex) * : This command is used For Zoom Position setting In external PRESET mode. ABC is expressed in Hex data

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. 8/10 38) Memorize Internal PRESET Position for Internal PRESET control *XXC7ZZXXYY Memorize the current zoom, focus, and digital zoom position value into the internal nonvolatile memory of the CAMERA for controlling the Internal PRESET Move. The memory position to store is indicated by the “INDEX” value. ZZ : (data range 00 ~ 3F hex) : Index counter 39) Internal Non Zoom Tracking PRESET Moving control *XXC8ZZXXYY Perform the Internal PRESET Moving action. ZZ : (data range 00 ~ 3F hex) : Index counter 40) Slow Speed Internal Zoom Tracking PRESET Moving control :XXCFZZXXYY Perform the Zoom Tracking PRESET action to the target zoom position slowly. The target zoom position value is memorized in the internal nonvolatile memory. ZZ : (data range 00 ~ 3F hex) : Index counter 41) Quick Speed Internal Zoom Tracking PRESET Moving control :XXD0ZZXXYY Perform the Zoom Tracking PRESET action to the target zoom position Quickly. The target zoom position value is memorized in the internal nonvolatile memory. ZZ : (data range 00 ~ 3F hex) : Index counter CF) Internal Preset Mode usage 1. Using “ Memorize Internal PRESET Position “ Command, Memorize each position To camera 2. Using “ Preset Moving control “ Command, Move Zoom and Focus Lens to each Memorized position every position is accessed by index counter

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. Appendix: Key Code Table 1/2 KC_STOP 09 ; After the other key commands below this command must be followed after. If continuous key service is needed send this command several seconds after the before command. In other words, when you want a certain function you can send below key codes when you want to stop the function send this command again. KC_POWER 0A ; Toggles power on/off status KC_TELE 01; Slow zoom tele action KC_WIDE 03 ; Slow zoom wide action KC_QTELE 02 ;Fast zoom tele action KC_QWIDE 04; Fast zoom wide action KC_FAR 05;Focus lens move action to far direction ( in manual focus mode) KC_NEAR 06 ;Focus lens move action to near direction ( in manual focus mode) KC_FAM 0B;Toggles focus Auto/Manual Modes KC_F_PUSH 0C; Activates Focus auto action on time KC_SET 0D; In menu mode, toggles item selection mode/ item adjust mode KC_Default 0E; by this code all conditions in camera returns to manufacturer’s conditions KC_OSD 0F; Toggles function osd off/on modes KC_MENU 10; Toggles menu on/off modes KC_BL 13; Toggles backlight mode KC_FLICKER 14 ; Toggles flicker mode KC_SSC Up 15; Shutter speed counter up KC_SSC Down 16 ; Shutter speed counter down KC_DEFT 17 ;Switches digital effect modes WIDE→ART → MIRROR → NEGA80 MONO → MOSAIC KC_MIRROR Con. 18;Toggles Mirror mode KC_NEGA 19;Toggles nega mode KC_MONO 1A ;Toggles mono mode KC_WIDE 38 ; Toggles wide mode KC_MOSAIC 39 ;Toggles mosaic mode KC_ART 3A ; Toggles art mode 9/10

ONZ-AN101/151/102/152, AP101/151/102/152 Specifications ONIX SYSTEM INC. Appendix: Key Code Table 2/2 KC_SRPUP 1C;sharpness data up KC_SRPDN 1D;sharpness data down KC_BRTUP 1E ;Brightness data up KC_BRTDN 1F;Brightness data down KC_ZoomSup 20 ;Zoom Start up KC_ZoomSdn 21 ;Zoom Start down KC_ZoomEup 22;Zoom End up KC_ZoomEdn 23;Zoom End down KC_WB_PUSH 24;In white balance push auto mode (manual mode ),initiates “push action” KC_AWBup 25 ;Switches awb modes auto → special → Indoor → outdoor → hue control → puah auto KC_AWBdn 26 ;Switches awb modes in reverse sequence to KC_AWBup KC_RadjUP 27;In Special WB mode,R gain goes up KC_RadjDN 28;In Special WB mode,R gain goes down KC_BadjUP 29;In Special WB mode,B gain goes up KC_BadjDN 2A;In Special WB mode,B gain goes down KC_HUEUP 2B ;In HUE adjust WB Mode the picture become Reddish KC_HUEDN 2C;In HUE adjust WB Mode the picture become Bluish KC_AE_Man 2D;Turns AE mode to Manual mode KC_IrisUp 2E;Increase IRIS Level KC_IrisDn 2F ;Decrease IRIS Level KC_AGCup 30 ;Increase AGC Gain KC_AGCdn 31 :Decrease AGC gain END Example of Key action transfer # Zoom Lens moving example Send commands following this sequence! 1 → 2 → 3 Every codes are transferred and received in ASCII codes 1. *XX75ZZXXYY ( move to tele ) XX=don’t care ZZ = 01 (KC_TELE) YY=Check Sum Data =>assume XX to be 00,then the check sum becomes Y Y 2A(‘*’) + 30(‘0’)+ 30(‘0’)+37(‘7’)+35(‘5’)+ 30(‘0’)+ 31(‘1’)+30(‘0’)+ 30(‘0’) = ‘B’ ‘7’ 2. Software delay ( The time you desired to move ) 3. *XX75ZZXXYY (stop action ) ZZ:09 (KC_STOP) 10/10