LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
CL100D series DSP controlled Uninterruptible power supplies.
POWERVALUE KVA.
Match UPS Product Management July Match UPS Product Management July 29th, 2004 Range Topology Unique Selling Points Key Features Accessories Applications.
Static Transfer Switch
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
G.E. UPS Productline.
Model B1 19-inch Rack Static Transfer Switch. Why choose a model B1 static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Total HVAC Control from anywhere Easy control that can save a fortune
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
MODULAR SMPS POWER PLANT
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
LP33 Series UPS kVA 400Vac/CE
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
April 2004 page 1 Confidential and propietary CentraLine Portfolio c l o s e t o y o u.
NT series introduction UPS training June 2006 Markus Schwab.
Introducing GAC’s New Line of Intelligent Generator Set Controllers.
UPS H series introduction UPS training June 2006 Markus Schwab.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior.
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004.
UPS SG-CE Series kVA Sales presentation.
FG Wilson Access 4000 Control Panel
SG-CE Series kVA PurePulse®
Janus Convertible Line – interactive Series UPS
AC backup solutions for business continuity. Secure your business, Stay on!
POWER PLANT USED IN TELECOM
MarsⅡ On-Line UPS Series
ML Series Product Presentation Product Management May 2004.
PowerScale 10-50kVA Ed Maximize your availability.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Smart Grid: Opportunities in the Data Center January 22, 2010 Charles O’Donnell, Vice President, Engineering Liebert AC Power Emerson Network Power.
Modular Inverter.
RACK Mountable & Modular Continuous Power Protection Availability
650 VA Power Tree UPS 650VA 100% Stabilized Output Power
Power Quality Product Overview
LP Series 400V CE GE Consumer & Industrial September 2004.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
1 Powerware VA – 3kVA Nonstop perfect power for networks, web servers and telecommunications applications.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Avaya 9130 and 9135 Online UPS 1000 to 6000 VA. Avaya Applications Advanced power protection for: u S8700/S8500/S8300/S8100 Media Servers u Unified Communications.
© 2007 Eaton Corporation. All rights reserved. Powerware ® BladeUPS Highest efficiency power protection for today’s IT environment.
FLATPACK Rev.5 September 2002 Updated versions may be available.
© 2013 Eaton Corporation. All rights reserved. Eaton 5SC Affordable and reliable Line Interactive UPS for Server protection.
InfraStruXure Systems Alex Tavakalov
© 2011 Eaton Corporation. All rights reserved. Configuring BladeUPS™
UPS SG-CE Series 300 kVA. SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V.
Avaya VA Line-interactive UPS
Avaya Online UPS 6000 VA.
Avaya Online UPS 6000 VA.
V7 UPS Sales Training.
PowerValue 11 RT Sales Presentation
Energy. Anytime. Anywhere.
True modular UPS system for critical applications
Maximize your availability
PowerValue 11/31 T Sales Presentation
Best-in-class modular UPS ensuring business continuity
Online Emergency Lighting Inverter
Online Emergency Lighting Inverter
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Stand-By Emergency Lighting Inverter
Online Emergency Lighting Inverter
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Presentation transcript:

LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection

LP Series On-line hardwired UPS single phase 3-10kVA CE Marked

Range Product description “Hot buttons” Specifications Features & Benefits Options RPA ( Redundant Parallel Architecture) Segments and Applications Contents Introduction

LP-11 Series 3/5/6/8/10: 230 Volt single phase in and out LP-31T Series 5/6/8/10: 400 Volt three phase in and 230 Volt single Phase out Range

True on-line double conversion Power factor 0.99 at input Electronic and manual bypass Fully isolated output Easy maintenance Product Description

DC connector for additional battery packs Input fuses Three option slots Manual bypass switch I/O terminals LC display, 2 LEDs 3 push-buttons

Power factor corrected input Automatic bypass Maintenance bypass switch Maintenance bypass preserves voltage conversion & isolation Cold start (unit can be started with no AC present) Multi language display Unique RPA Hot Buttons

LCD screen Automatic battery testing –every 500 hrs. No load shutdown No load inrush current Superior overload handling Easy to service Backfeed relay in 31T versions Hot Buttons (continued)

LP Series kVA- 2.4 kW LP Series 5-11 / 31T 5 kVA - 4 kW LP Series 6-11 / 31T 6 kVA kW LP Series 8-11 / 31T 8 kVA kW LP Series / 31T 10 kVA - 8 kW Specifications

Input Voltage LP 11 Input Voltage LP 31T Vac I phase Vac 3-ph / 4 wire Output Voltage LP 11 and LP 31T 220 / 230 / 240 Vac 1 phase Output Frequency Hz Specifications Voltages and Frequencies

True On-Line - double conversion HF PWM technique No load (< 2%) shutdown with no utility Bypass enable / disable Programmable frequency tracking range (2%, 4%, 6%) Specifications Voltage and Frequency Independent

Superior Battery Management Automatic battery test Battery calibration test Boost charging Temp. compensated charger Load dependent EOD voltage No-load shutdown Features & Benefits

Superior Battery Management Maximum Up-time Prevents Damage Prolonged Battery Lifetime No Surprises Automatic battery test Deep calibration test Boost charging Temp. compensated charger Load dependent EOD voltage No load shutdown Features & Benefits

ECO-mode High efficiency (97%), low energy costs On board event logging Easy and fast diagnostic Multi-lingual LC display Shows all operational parameters in language to choose from GB / NL / D / IT / ES Design front Elegant design, fits with all modern ICT products Features & Benefits

Emergency power off (standard) Emergency shutdown in case of fire or water alarms Excellent Overload Behavior Withstands most toughest conditions Isolation transformer Ultimate protection from disturbances Tracking speed is selectable Optimized for generator supply Features & Benefits

Redundant Parallel Architecture Unique RPA system SNMP plug-in card (web enabled) For direct integration into networks Relay card (plug-in) Integration into third party systems Additional battery packs Longer runtimes Backfeed protection relay Safe maintenance Options

Redundant Parallel Architecture Up to 4 units in parallel Bypass and batteries redundant Control logic redundant Field-upgradeable (single>parallel) RPA

As well as the UPS, the bypass, the batteries and the control logic are redundant. This provides real redundancy. The result is a high system reliability. MAINS LOAD RPA Reliability Flexibility Serviceability

Reliability Flexibility Serviceability By adding units you can upgrade the total power rating of the system. This can be performed on-site by a service engineer. MAINS LOAD RPA

Reliability Flexibility Serviceability In a redundant system 1 unit can be removed for service purposes. The other units still supply the load, providing full protection. MAINS LOAD RPA

Segments and Applications SEGMENTS AND APPLICATIONS LP Series

Main Segments Industry Information Technology Telecom

Industry Industry applications: Airports/Railroads Tunnels Building Control Process Automation

Industry Easy installation Low operational cost Service friendliness Information on the spot Compatibility with other systems Generator operation Small and light SBM and ECO-mode Complete UPS on one printed circuit board Multi-lingual LCD Intelligent interface, relay contacts, EPO Adjustable bypass window and tracking rate, optimal for genset Requires:LP Series offers:

Contractors Like it because it is simple to install… Small and lightweight Low cost wiring: Powerfactor =1 input & easy to service. Standard maintenance Bypass LCD shows operational parameters

Information Technology IT applications: Server rooms Business critical applications Midrange computer systems Back offices

Information Technology Requires: LP Series offers: 24x7 power availability High reliability Remote management Floor space Elegant appearance SBM, manual bypass RPA (true redundancy) JUMP is bundled for free Small footprint Nice! Isn’t it?

EDP Managers Want a managed solution... Easy to connect to any network Remote modem and snmp management to prevent any disaster. Regular automatic self test Superior Battery Management

Telecom Telecom applications: Mobile communication Central switch boards

Telecom High reliability Battery care Maximal runtimes and fast recharging Low distortions Isolation from mains RPA SBM and wide input voltage window Battery packs (easy to install) and increased charger current available (5/6kVA) PF 0.99 at input and THD < 2% at output Standard isolation transformer Requires:LP Series offers:

Telecom Desire approved specifications… Complying to the world’s highest standards Most reliable design & remote solutions. Extended runtime versions up to hours Remote diagnostics and service

Conclusion Strengths of LP Series : Excellent specifications Standard equipped with many features Low operational costs A winner in tenders