Presentation is loading. Please wait.

Presentation is loading. Please wait.

Maximize your availability

Similar presentations


Presentation on theme: "Maximize your availability"— Presentation transcript:

1 Maximize your availability
Standalone tower three-phase UPS system PowerScale10-50 kVA 3ph UPS Maximize your availability

2 PowerScale 10-50 kVA Content Feature Highlights
Available models and battery runtimes Performance characteristics Battery and runtimes System installation and wiring Cabinet design Connectivity Options and accessories © ABB September 21, 2018

3 PowerScale 10-50 kVA Feature highlights Feature Highlights: 25-50 kVA
Highest reliability and increased availability with True on-line double conversion (VFI) UPS – 3ph input / 3ph output Minimizes energy losses with industry top-level double conversion efficiency up to 95.5% Optimized for modern IT loads with rated output power factor 0.9 Low input line disturbances; input PF 100% load – ITHD ≤ 3% Up to 20 units can be connected in parallel for redundancy and/or to increase system capacity “All included” with integrated manual bypass switch No nasty surprises in the event of utility failure – manual and automatic battery tests ensure that battery health is know at all times Ease of servicing and short MTTR ensure cost for downtime – scheduled and unscheduled – is minimized High variety of runtimes can be supported by using cabinet internal batteries only. This makes the system compact and saves installation space. Fit for different installation environments by having both, single or dual input feed, supported. 25-50 kVA 10-25 kVA 10-20 kVA CABINET A CABINET B CABINET C © ABB Group

4 UPS cabinets and battery runtimes
PowerScale kVA UPS cabinets and battery runtimes Three different size cabinets to cover the power range from 10 – 50 kVA Most commonly needed runtimes can be managed by simply using internal batteries CABINET A CABINET B CABINET C Dimensions 345 x 720 x 710 mm 345 x 1045 x 710 mm 440 x 1400 x 910 mm Weight without batteries kg kg kg Maximum runtimes with internal batteries at full nominal load 10 kVA / 9 kW 15 min 35 min na 15 kVA / 13.5 kW 10 min 20 min 20 kVA / 18 kW 6 min 25 kVA / 22.5 kW 13 min 30 kVA / 27 kW 40 kVA / 36 kW 50 kVA / 45 kW 9 min © ABB September 21, 2018

5 Performance characteristics – High efficiency
PowerScale kVA Performance characteristics – High efficiency Top-of-the-market efficiency saves energy and reduces running costs resulting to lower TCO Having the curve flat means that high efficiency is reached already at low load levels 94.5 – 95.5% though the typical operating range! Note: Chart data applies directly to 10-15kVA models. For other models, results may have small variation. © ABB September 21, 2018

6 Performance characteristics – Low input harmonics
PowerScale kVA Performance characteristics – Low input harmonics Advanced Booster Power Factor Control (PFC) allows for achieving reduced current total harmonic distortion (THDI) and close to unity input power factor even with partial loads. Multiple energy and cost saving benefits follow: No phase compensation filter required UPS respects power grid regulations without additional hardware Generator size can be optimized for the load Smaller cable/fuses/breakers sizes can be applied No extra heating of transformers © ABB September 21, 2018

7 Batteries and runtimes
PowerScale kVA Batteries and runtimes Most commonly required battery runtimes can be supported by using cabinet internal batteries only. This makes the system compact and saves installation space. Standard 12V VRLA batteries are used: CABINET A & B: 7Ah or 9Ah batteries CABINET C: 7Ah, 9Ah or 28Ah batteries Number of battery blocks in a battery string can vary  flexibility to optimize battery configuration to match exactly the runtime requirement and no oversizing is needed. (for details, please see technical specification) Battery tests can be performed manually or automatically in configurable periods. Periodic testing assures that battery health is know and no nasty surprises occur in the event of utility power failure. Temperature compensated charging capability as standard (temperature sensor provided optional) UPS RATED OUTPUT POWER 10 kVA 15 kVA 20 kVA 25 kVA 30 kVA 40 kVA 50 kVA Cabinet type A B C Max. number of batt. 7/9 Ah 1 X 48 2 X 48 3 X 48 Max. number of batt. 28 Ah n.a. 1 x 48 Max. runtime with internal batteries at full nominal load 15 min 35 min 10 min 20 min 6 min 13 min 9 min © ABB September 21, 2018

8 System installation and wiring
PowerScale kVA 3ph UPS System installation and wiring PowerScale supports both single and dual input feed schemes by standard. The UPS also has readily a maintenance bypass switch (MBS) integrated so no expensive external solution is required. To change from single input to dual input and vice versa is achieved simply by removing electrical links/bridges. PowerScale kVA wiring terminals PowerScale kVA wiring terminals © ABB September 21, 2018

9 UPA cabinet design – CABINET A
PowerScale kVA 2 slots for optional connectivity cards SNMP (optional) Relay card with voltage free output contacts + USB port (optional) UPA cabinet design – CABINET A LCD Display and mimic diagram RS232 Voltage free input contacts Multidrop port Parallel kit Air inlets Bypass fuse Battery fuse Rectifier fuse Manual bypass Wheels UPS disconnect I/O connection FRONT REAR © ABB September 21, 2018

10 UPA cabinet design – CABINET B
PowerScale kVA 2 slots for optional connectivity cards SNMP (optional) Relay card with voltage free output contacts + USB port (optional) UPA cabinet design – CABINET B RS232 Voltage free input contacts Multidrop port LCD Display and mimic diagram Parallel Kit Air inlets Battery fuse Bypass fuse Rectifier fuse Manual bypass UPS disconnect Wheels I/O connection FRONT REAR © ABB September 21, 2018

11 UPA cabinet design – CABINET C
PowerScale kVA RS232 Voltage free input contacts Multidrop port Parall. Kit UPA cabinet design – CABINET C LCD Display and mimic diagram 2 slots for optional connectivity cards SNMP (optional) Relay card with voltage free output contacts + USB port (optional) Removable Front Panel Rectifier fuse By-pass fuse Battery fuse Air inlets Manual By-pass Wheels UPS disconnect I/O connection © ABB September 21, 2018

12 Human-machine interface
PowerScale kVA 3ph UPS Human-machine interface Easy to use - intuitively working UPS display Mimic diagram displays UPS status and power flow Menu driven LCD allows for: Monitoring input/output current, voltage and power as well as available runtime and other important characteristics. Control of the UPS: start-up, shut-down and transferring between operating modes Access the event register for self diagnosis Most important information always available at first glance © ABB September 21, 2018

13 Options and accessories
PowerScale kVA Options and accessories STANDARD OPTIONS AND ACCESSORIES External battery cabinet (line-and-match) SNMP slot card (web enabled) Shutdown software Potential free output contact slot card, including USB port Parallel kit (one additional PCB + one parallel adapter) Parallel cables of different lengths Back feed protection Temperature probe ON REQUEST Emergency Shut Down I/O Transformer for galvanic isolation or voltage adaptation, special I/O configuration © ABB September 21, 2018

14 Options and accessories – External battery cabinet
PowerScale kVA Options and accessories – External battery cabinet Line-and-matching battery cabinet, same design and color of the UPS Same dimension as PowerScale Cab. C (WxHxD 475x1400x940mm) Extended autonomy 1x 48x 28Ah  up to 6 45 kW 2x 48x 28Ah  up to 15 45kW Can be used to host I/O isolation transformer(s) upon request © ABB September 21, 2018

15 PowerScale 10-50 kVA Connectivity INCLUDED BY STANDARD OPTIONAL
RS232 on Sub-D9 port Input Dry Contacts: Remote shut down Generator ON Programmable Input: Customer IN1 Temp Sensor for Battery 12VDC Source RJ 45 for Multidrop SNMP Card Optional Card Relay card with voltage free output contacts: Common Alarm Load on Bypass Battery low Load on Inverter Mains Failure USB port © ABB September 21, 2018