Who am I? ● Daniel John Kirby ● Carnegie Mellon Physics Class of 2013 ● In Hall A June-July 2012.

Slides:



Advertisements
Similar presentations
Structure of the front-end DAQ for DIS PARITY in Hall A Bogdan Wojtsekhowski with Bob Michaels and Albert Shahinyan Jlab, 12/1/ 2006 The issues: e/pi rejection.
Advertisements

Preparing the Big Bite Hadron Detector Package Gordon Lott, Virginia Tech Mentor: Douglas Higinbotham All the signals from the PMTs are sent via cable.
SBS Hadron and Electron Calorimeters Mark Jones. SBS Hadron and Electron Calorimeters Mark Jones Overview of GEn, GMn setup Overview of GEp setup The.
Status of MRPC-TOF Wang Yi Department of Engineering Physics Tsinghua University, Beijing, China 1.
Introduction (Font: Arial 44) Please prepare your poster according to the following specifications: (Font: Arial 32) 1.Poster size 100 cm X 70 cm. 2.All.
A Muon Veto for the Ultra Cold Neutron Asymmetry Experiment Vince Bagnulo with Dr. Jeff Martin Electrons Ultra Cold Neutrons Cosmic Ray Muons Protons Pions.
MICE: The International Muon Ionization Cooling Experiment Diagnostic Systems Tracker Cherenkov Detector Time of Flight Counters Calorimeter Terry Hart.
1 Status of infrastructure MICE Video Conference, August 17, 2005 Yury Ivanyushenkov Applied Science Division, Engineering and Instrumentation Department.
Update on the Gas Ring Imaging Cherenkov (GRINCH) Detector for A 1 n using BigBite Todd Averett Department of Physics The College of William and Mary Williamsburg,
TOC 1 Physics 212 and 222 Motion in a Magnetic Field Motion of Charges in Magnetic Fields Mass Spectrometer Velocity Selector.
MICE Tracker Readout and Data Acquisition; Solenoid Magnetic Field Measurement Terry Hart for the MICE Collaboration, Illinois Institute of Technology,
U niversity of S cience and T echnology of C hina Design for Distributed Scheme of WCDA Readout Electronics CAO Zhe University of Science and Technology.
Shielding the Weiner PSU 7 May 2013 Kiril Marinov ASTeC, MaRS, DL 1.
SBS/A1n DAQ status Alexandre Camsonne August 28 th 2012.
0 A Fast Time Incorporating Monte-Carlo Simulation of Wire Chamber Based Small Animal PET Scanners for Detector Scatter Correction M. Dawood 1, Don Vernekohl.
Hall A DAQ status and upgrade plans Alexandre Camsonne Hall A Jefferson Laboratory Hall A collaboration meeting June 10 th 2011.
Cosmic Rays: Ever Present and Useful Anthony Gillespie Denbigh High School Mentor: Dr. Douglas Higinbotham Cosmic Rays Using the Cosmic Rays Current Research.
GEANT Study of Electron ID and  0 Rejection for Containerized detectors Compare detectors in shipping containers to idealized continuous detector with.
PHOBOS TOF Construction Status
John LeRose March 12, A Program of three “projects” to assemble the Super BigBite Spectrometer for a series of experiments in Hall A There is a.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
Simple Double Beam Spectrometer
PV-DIS Toroid Detector: outline and costs Paul E. Reimer 12 GeV PV-DIS detector meeting August 1.Introduction to Toroid Concept (presenting work.
Design and optimization of Electromagnetic particle Detectors (EDs) in LHAASO-KM2A Xiangdong Sheng, Jia Liu, Jing Zhao on behalf of the LHAASO collaboration.
Research student: Gustavo A. Gandara Montano
PANDA FTOF Prototyping Anton A. Izotov, Gatchina
Cherenkov Counters for SoLID Z.-E. Meziani on behalf of Simona Malace & Haiyan Gao (Duke University) Eric Fuchey (Temple University) SoLID Dry Run Review,
BigBite Spectrometer Equipment by Douglas W. Higinbotham.
The calibration and alignment of the LHCb RICH system Antonis Papanestis STFC - RAL for the LHCb Collaboration.
Introduction (Font: Arial 44) Please prepare your poster according to the following specifications: (Font: Arial 32) 1.Poster size 100 cm X 70 cm. 2.All.
Super Bigbite collaboration meeting 4-5 June 2013 slide 1 June 4 th 9:00-9:10 Welcome/SBS Overview ( BW ) 10’ 9:10-9:45 High-t form factors and short-range.
V. Vorobel, SuperNEMO meeting, Aussois Vacuum system upgrade Vacuum probe installed Spectrometer sealed – vacuum improved from 300 Pa to 7 Pa.
CEDAR Support Structure Peter Sutcliffe 24 th January 2011.
Forward Muon Installation and Commissioning Dmitri Denisov Fermilab Director’s review 7/12/1999 Plan Forward muon detectors Mini-drift tubes installation.
RICH upgrade simulation: updates S.Easo RICH upgrade-mechanics meeting 1.
TELL1 high rate Birmingham Karim Massri University of Birmingham CEDAR WG Meeting – CERN – 26/03/2012.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Online Reconstruction 1M.Ellis - CM th October 2008.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
Tracking (wire chamber) Shield radon, neutron,  Source foil (40 mg/cm 2 ) Scintillator + PMT 2 modules 2  3 m 2 → 12 m 2 Background < 1 event / month.
Update on the GRINCH Detector SBS meeting, 21 Oct 2015 T. Averett, W&M JLab, NC A&T, JMU, Glasgow Timing-based gas Cherenkov detector PMT array-510 tubes.
Update on the Gas Ring Imaging Cherenkov (GRINCH) Detector for A 1 n using BigBite Todd Averett Department of Physics The College of William and Mary Williamsburg,
June 7, 2004Karen Dow CODA at Bates BLAST Data Acquisition.
Jefferson Laboratory Hall A SuperBigBite Spectrometer Data Acquisition System Alexandre Camsonne APS DNP 2013 October 24 th 2013 Hall A Jefferson Laboratory.
Methods to reduce dead time and achieve higher trigger rate. Sparsification Event blocking Parallel DAQ systems SFI Sequencing.
Integration of Forward Detectors, ZDC, and CASTOR into CMS Experiments Kevin Reynolds Michael Murray, Mentor David d'Enterria, Co-mentor 2006 Michigan.
SBS/A1n Fast DAQ Alexandre Camsonne October 19 th 2012.
E. W. Grashorn and A. Habig, UMD, for the MINOS Collaboration The Detectors of The Main Injector Neutrino Oscillation Search (MINOS) Experiment The MINOS.
APEX DAQ rate capability April 19 th 2015 Alexandre Camsonne.
SBS / A1n DAQ Alexandre Camsonne 02/27/2013. APV25 Standard VME access ok : can configure board Check address assignment in VME64X crate Need to debug.
PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements:  Expected total rate for 9.25 < R < 120 cm: 12.1 MHz:
1 Implementation at RAL Iouri Ivaniouchenkov on behalf of Elwyn Baynham, Tom Bradshaw, Tony Jones, Jim Rochford Engineering Department, RAL MICE Collaboration.
Super BigBite DAQ & Trigger Jens-Ole Hansen Hall A Collaboration Meeting 16 December 2009.
Sardana/IcePAP Based Control System for elliptically polarized Undulator at Max IV 30th Tango Collaboration meeting
Title of the Poster (Font: Arial 72)
Title of the Poster (Font: Arial 72)
FCC-ee IR magnetic element design – an update
MAENTOUCH Simulation Giles Quéméner – IN2P3/LPC Caen
SBS Magnet, Optics, and Spin Transport
Hall A Compton Electron detector overview
M. Jones B. Wojtsekhowski
Sergey Abrahamyan Yerevan Physics Institute APEX collaboration
CLAS12 Timing Calibration
RICH1 B-field Measurements Conclusions:
The PrimEx-I Experiment
Geant4 in HARP V.Ivanchenko For the HARP Collaboration
How magnet opening affects PVDIS acceptance
Title of the Poster (Font: Arial 72)
Extendible Hashing Example
Hall probe Location on top or bottom
Presentation transcript:

Who am I? ● Daniel John Kirby ● Carnegie Mellon Physics Class of 2013 ● In Hall A June-July 2012

Task: Implement systems to make FASTBUS readout faster (using CODA)

The Goal: Reducing Deadtime Main Sources of Deadtime Conversion Readout

Mathematical Model

Tasks to Implement Multiblock Readout SFI sequencing Event Blocking and Parallel Buffering Module Buffering Sparsification Library Implementation

Sparsification

Event Blocking Illustrated Thanks to Dave Abbott for this idea.

Increasing the Buffer Depth

Parallel Buffering Split TDC buffer into two distinct buffers. Readout and trigger acceptance can happen concurrently

Sequential vs. Parallel Buffering

Looking Forward: Parallel Module Buffering Reduces effective trigger rate. Thanks to Igor Rachek for original concept. Thanks to Bryan Moffit for help improving this diagram.

Effect of Module Buffering

Acknowledgements Once again I'd like to extend special thanks to: Bogdan Wojtsekhowski Bryan Moffit Dave Abbott Igor Rachek

Magnetic Field in Gas Cherenkov Counter By: Austin Milby, Menchville High School, class 2013 Physics is COOL!

Magnetic Field in Gas Cherenkov Counter Introduction WHAT: Shielding of PMT’s from magnetic field generated by BigBite WHY: Magnetic field can cause electrons in PMT to change direction and bend away from dynodes, resulting in skewed data HOW: By implementing a magnetic shielding box for use in the Cherenkov Counter, we can reduce the presence of the magnetic field around the PMT’s which will result in more accurate data Study done by SLAC found that Y-orientation of PMT is most severely affected by magnetic field. Need field to be bellow 1 Gauss!

Detector of the BigBite spectrometer in A1n experiment I am working with magnetic shielding of the PMT for the Gas Cherenkov counter

BigBite magnet and the field components Field components are of 5-10 Gauss At PMT the field need to be reduced to the level of Gauss Bz component, Gauss By component, Gauss Bx component, Gauss -100cm 100cm (through center of Cherenkov Counter)

The layout of the PMTs in the counters Design of Magnetic Shielding Box being considered for use in detector. It will be placed in green area on picture. Mirror PMT face Center of counter where data on previous slide was obtained

BigBite Magnet and the Field Components (2) (Data taken along purple line) Bx component, Gauss By component, Gauss Bz component, Gauss (Along surface of PMTs) 100cm -100cm

Magnetic Shielding Black box outlines location of PMTs in shielding box. PMT faces NOTE: Data taken with external field of 20 Gauss and current in compensation coil set at 120 amps