Presentation is loading. Please wait.

Presentation is loading. Please wait.

MICE Tracker Readout and Data Acquisition; Solenoid Magnetic Field Measurement Terry Hart for the MICE Collaboration, Illinois Institute of Technology,

Similar presentations


Presentation on theme: "MICE Tracker Readout and Data Acquisition; Solenoid Magnetic Field Measurement Terry Hart for the MICE Collaboration, Illinois Institute of Technology,"— Presentation transcript:

1 MICE Tracker Readout and Data Acquisition; Solenoid Magnetic Field Measurement Terry Hart for the MICE Collaboration, Illinois Institute of Technology, NFMCC Meeting, March 18, 2008

2 Outline Tracker Readout –Introduction –MICE Modifications –Plans MICE Data Acquisition (DAQ) –DAQ Subsystems and Structure –Front End Electronics Solenoid Magnetic Field Measurement –Initial Progress –Issues and Questions –Planning for Measurements Terry Hart, NFMC CM, March 18, 2008 2 of 29

3 MICE Tracker Acronyms AFE-IIt – Analog Front End, Version II, with time VLSB – VME LVDS Serdes Buffer –Versa Module Eurocard –Low Voltage Differential Signaling –Serialing/Deserializing TriP-t – Trigger with Pipeline with time VLPC – Visible Light Photon Counter Terry Hart, NFMC CM, March 18, 2008 3 of 29

4 IIT graduate student, Michael Wojcik, with a fully tested AFE-IIt board. AFE-IIt Boards Terry Hart, NFMC CM, March 18, 2008 4 of 29

5 AFE-IIt/D0/MICE Background AFE-IIt boards are latest D0 tracker readout boards. D0 and IIT arrangement –IIT students test boards for D0 –MICE received 22 boards D0 firmware not fast enough for MICE muon rate Substantial efforts from FNAL, IIT, and RAL to modify firmware for MICE Terry Hart, NFMC CM, March 18, 2008 5 of 29

6 Tracker Readout “Big Picture” Scintillating Fiber Tracker (1 of 2) –Measures track trajectory and momentum –Placed in solenoid Terry Hart, NFMC CM, March 18, 2008 6 of 29

7 Tracker Readout “Big Picture” Scintillating Fiber Tracker (1 of 2) –Measures track trajectory and momentum –Placed in solenoid AFE-IIt boards (4 of 16) –Mounted on 4 VLPC cryostats –Record, format data from tracker Hit fibers Charge Time Terry Hart, NFMC CM, March 18, 2008 6 of 29

8 Tracker Readout “Big Picture” Scintillating Fiber Tracker (1 of 2) –Measures track trajectory and momentum –Placed in solenoid AFE-IIt boards (4 of 16) –Mounted on 4 VLPC cryostats –Record, format data from tracker Hit fibers Charge Time VLSB boards (2 of 16) –Store formatted tracker data –Send data to MICE data acquisition (DAQ) Terry Hart, NFMC CM, March 18, 2008 6 of 29

9 MICE Time Scales, TriP-t Average time between MICE triggers ~ 1700 ns, as short as 628 ns TriP-t chips (16 on AFE-IIt board, 32 channels/chip) –Pipeline: stores analog charge and time data. (Event trigger formation takes ~ 1000 ns) –Analog buffer: upon trigger, data from pipeline and either Digitized if 4-level buffer empty or Placed in 4-level buffer if digitization of previous event not yet done TriP-t pipeline and buffer tested and working Terry Hart, NFMC CM, March 18, 2008 7 of 29

10 MICE AFE-IIt Firmware Modifications Reduce time to digitize events –Enable TriP-t pipeline to collect data during digitization of event –Cycle through non-hit channels as quickly as possible –Digitization time will be reduced from 5700 ns to 1600 ns. Implement TriP-t 4-level buffer –Board can accept, hold data in buffer while previous data digitizing –Increases recordable event rate for high input rate, short digitization time Enable AFE-IIt clock to lock onto variable signal –ISIS clock frequency varies from 52.2 – 55.6 MHz each trigger Terry Hart, NFMC CM, March 18, 2008 8 of 29

11 No Buffering 1-level Buffering 2-level Buffering 3-level Buffering 4-level Buffering 1000200030004000 120 0 240 360 480 600 Recordable Muon Rate (kHz) Digitization Time (ns) Estimate of Recordable Muon Rate vs. Digitization Time, Buffer Level 9 of 29

12 MICE Tracker Readout Plans Near term: Cosmic ray tests at RAL –Putting together simplified firmware at FNAL –Perform full test at FNAL before shipment to RAL –About a few week time scale Longer term: High rate MICE running –Sequentially add functionality Zero suppression 4-level buffer Variable clock Terry Hart, NFMC CM, March 18, 2008 10 of 29

13 VLSB Boards 2 VLSB boards in VME crate Terry Hart, NFMC CM, March 18, 2008 11 of 29

14 VLSB Firmware Tracker data storage modules Used for KEK test beam Used by D0 for diagnostics VLSB = VME LVDS Serdes Buffer Terry Hart, NFMC CM, March 18, 2008 12 of 29

15 VLSB Firmware Modifications Data storage in memory banks –Before modifications –After modifications Newly utilized registers for MICE DAQ –4 registers, each one for each memory bank address of last data word –1 register for number of events in spill –1 register to initiate fast clear of memory banks after each spill EVENT 1EVENT 2EVENT 3 … EVENT 1EVENT 2EVENT 3 … zeros Terry Hart, NFMC CM, March 18, 2008 13 of 29

16 Tracker Readout Status/Summary AFE-IIt, VLSB firmware used for cryostat cassette characterization AFE-IIt firmware development –Package for low rate cosmic ray testing being assembled –Firmware for high rate running in advanced development VLSB firmware development done Terry Hart, NFMC CM, March 18, 2008 14 of 29

17 MICE DAQ Terry Hart, NFMC CM, March 18, 2008 15 of 29

18 MICE DAQ MICE and ISIS Introduction MICE Detector Front End Electronics Software and MICE DAQ Architecture Terry Hart, NFMC CM, March 18, 2008 16 of 29

19 Systems for MICE DAQ Target System: Titanium target inserted into ISIS proton beam produces pions decaying to muons. RF Cavities: Eight 201 MHz cavities accelerate muons along MICE. DAQ: Data from MICE trackers, calorimeter, Cherenkov detectors, and time-of-flight counters combined to form MICE events. … ISIS proton spill → MICE target → pions,muons → MICE RF Cavities and Detectors Terry Hart, NFMC CM, March 18, 2008 17 of 29

20 Detector Front End Electronics Tracker –D0 AFE-IIt boards with firmware modificatons Time-of-Flight –CAEN V1290 TDC with constant fraction discriminators Calorimeter, Cherenkov –CAEN V1724 coupled with RC shapers Terry Hart, NFMC CM, March 18, 2008 18 of 29

21 MICE DAQ Hardware and Software MICE DAQ software from DATE framework used by CERN experiment ALICE –ALICE = A Large Ion Collider Experiment –DATE = Data Acquisition and Test Environment MICE detectors read out over VME. Online data stream includes variables from MICE Control and Monitoring (MCM). Data runs stopped for subsystem fault status or connection problem. Terry Hart, NFMC CM, March 18, 2008 19 of 29

22 MICE DAQ Architecture DataFlow Trigger distribution Tracker Calorimeter Time of Flight Counters Trigger+ Cherenkov GigaBit Switch Event Builder OnlineStorage Online Monitoring Run Control Remote Mass Storage 100 MegaBit Switch VME Crates Optical links Linux PCs MICE Control and Monitoring Readout MCM Subnet Terry Hart, NFMC CM, March 18, 2008 20 of 29

23 MICE DAQ Summary DAQ architecture determined –DATE framework –Detector FEEs read out by VME –Control and monitoring established Detector FEEs under development –Tracker FEE software modified from D0 –FEE hardware for calorimeter, time-of-flight counters, and Cherenkov detectors set Trigger signals and run modes established MICE DAQ ready for initial beam. Terry Hart, NFMC CM, March 18, 2008 21 of 29

24 Solenoid Magnetic Field Measurement Terry Hart, NFMC CM, March 18, 2008 22 of 29

25 Solenoid Magnetic Field Measurement MICE solenoid consists of 5 coils and iron shield First solenoid expected at FNAL for magnetic field measurements in April Measurements to be done with ZipTrack system. Terry Hart, NFMC CM, March 18, 2008 23 of 29

26 Work to Date Simulations of field done with –Superfish (with and without iron shield) –FORTRAN numerical simulation –Analytic on-axis solution Meetings with FNAL Alignment Group who will survey magnet and measure field Terry Hart, NFMC CM, March 18, 2008 24 of 29

27 Tesla Meters Blue points of numerical simulation hidden by red line on-axis analytic solution. 5 magnet coils Shield location Terry Hart, NFMC CM, March 18, 2008 25 of 29 Analytic and Numerical Simulations of B z Along Solenoid Axis

28 Superfish Simulation of B z Along Solenoid Axis Terry Hart, NFMC CM, March 18, 2008 26 of 29

29 Effects of Iron Shield in Superfish Simulation 10,000 1000 10,000 1000 No Shield Shield Terry Hart, NFMC CM, March 18, 2008 27 of 29

30 Questions/Measurement Plan Iron shield affecting magnetic field? Measure field beyond ends of solenoid? (where time of flight counters will be) Measurement precision sufficient for MICE tracking and emittance measurement? Measure field in possible different modes? (different current densities in coils) Terry Hart, NFMC CM, March 18, 2008 28 of 29

31 Summary Tracker firmware for cosmic ray tests at RAL being put together Firmware for high rate MICE running well underway. MICE DAQ is ready for initial MICE beam Spectrometer field measurement and simulation program getting started Terry Hart, NFMC CM, March 18, 2008 29 of 29


Download ppt "MICE Tracker Readout and Data Acquisition; Solenoid Magnetic Field Measurement Terry Hart for the MICE Collaboration, Illinois Institute of Technology,"

Similar presentations


Ads by Google