Project Definition The aim of this project was to design a steerable catheter, which would enable easier access to specific blood vessels. The design would.

Slides:



Advertisements
Similar presentations
Basic Refrigeration Cycle
Advertisements

Manual Set-Up for Density by Hydrometer Method ASTM D1298, D287, D6822 and IP160 Feb
 Refining development of device using shape memory polymer foams to non-surgically treat aneurysms.  Developed research at Lawrence Livermore.  Chose.
Blood flow monitoring in cerebral vessels A. P. Chupakhin Lavrentyev Institute of Hydrodynamics, Novosibirsk, Russia Novosibirsk State University In collaboration.
MRAClub 2014 Accurate Estimation of the volume flow rate in the cerebral artery using 3D cine phase-contrast MRI (4D-Flow) P. 1 Tokyo Institute of TechnologyR.
Fluids Gases (compressible) and liquids (incompressible) – density of gases can change dramatically, while that of liquids much less so Gels, colloids,
Comparison of Surgical Treatments for Blocked Arteries By-Pass Surgery with Heart-Lung Machine By-Pass Surgery using Off-Pump Technique Angioplasty with.
FLUID FLOW IDEAL FLUID BERNOULLI'S PRINCIPLE How can a plane fly? How does a perfume spray work? What is the venturi effect? Why does a cricket ball swing.
Experimental and Numerical Study of the Effect of Geometric Parameters on Liquid Single-Phase Pressure Drop in Micro- Scale Pin-Fin Arrays Valerie Pezzullo,
Viscous Fluid Flow (14 p.341) Viscous Fluid Flow A. Prof. Hamid NEBDI Faculty of Applied Science. Department of Physics. Room: 315 second.
Team P08404: Team Members: Ben Johns (ME) Adam Yeager (ME) Brian T Moses (ME) Seby Kottackal (ME) Greg Tauer (ISE) Faculty Guide: Dr. Stevens Review Date:
CONTINUATION OF TYPES OF LIFE SUPPORT MACHINES. HEART/LUNG BY PASS CARDIOPULMONARY BY PASS(CPB) IS A TECHNIQUE THAT TEMPORARILY TAKES OVER THE FUNCTION.
Quick Connects Preliminary Concepts. Quick Connects - Tube and Stopper The overarching concept is to have two types of quick connects that interface with.
Turbulence After the Bend
Kern Method of SHELL-AND-TUBE HEAT EXCHANGER Analysis
Physical Principles of Respiratory Care
Fluid Mechanics 08.
Flow Sensors.
Kern Method of SHELL-AND-TUBE HEAT EXCHANGER Analysis
What is it?. Fluid Mechanics  The study of fluids and the forces on them.  What are fluids?
Pacemaker & its Classification
Chapter 11 – Part 5 The Cardiovascular System. Vital Signs  The following measurements are referred to collectively as vital signs in clinical settings:
The Cardiac Cycle, Pump Function & Blood Pressure.
1 Calorimeter Thermal Analysis with Increased Heat Loads September 28, 2009.
Fluid Properties: Liquid or Gas
MedTG Needle Design Steve Harris Adam Travis Brett Byram Group #15 Advisors: Gary Byram, Ph.D. Paul King, Ph.D., P.E.
Engineer Training Cooler TJ8300 / TJ8500 Cooler. Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction.
Chapter Six Non-Newtonian Liquid.
Viscous Flow.
Lesson 21 Laminar and Turbulent Flow
Things to grab for this session (in priority order)  Pencil  Henderson, Perry, and Young text (Principles of Process Engineering)  Calculator  Eraser.
Dynamics of Blood Flow Transport System A closed double-pump system: Systemic Circulation Lung Circulation Left side of heart Right side of heart.
Hemodynamics of the Vasculature
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. April 9, 2003.
CP502 Advanced Fluid Mechanics Compressible Flow Lectures 5 and 6 Steady, quasi one-dimensional, isentropic compressible flow of an ideal gas in a variable.
Intravascular Foreign Body Retrieval System Nathan Luibrand, Nicholas Luibrand, Lukas Richards, and Elise Adcock-Hinojosa Advised by Dr. Michael Barnett.
Design of a Steerable Catheter Steeratheter Cherry R. Abenojar Eric D. Benson Dr. Theodore Larson, Project Advisor.
Intravascular Foreign Body Retrieval System Nathan Luibrand, Nicholas Luibrand, Lukas Richards, and Elise Adcock-Hinojosa Advised by Dr. Michael Barnett.
Manual Density Business Today
Design of a Steerable Catheter Steeratheter
Improving Microcatheter Navigation Through the Brain Matt Kergosien Holly Bonar Advisor : Dr. Ted Larson.
Improving CABG Surgery
March 24, 2004BME 272/2731 Investigation of Bubble Formation in Tuohy-Borst Adaptors Department of Biomedical Engineering Melanie Bernard, Isaac Clements,
4.4.1 Unblocking the Vessel.
February 4, 2004BME 272/2731 Investigation of Bubble Formation in Tuohy-Borst Adaptors Department of Biomedical Engineering Melanie Bernard, Isaac Clements,
Fluids in Motion How does blood flow dislodge plaque from an artery? Why can a strong wind cause the roof to blow off a house? Why do people snore? © 2014.
Pulmonary Flow Resistive Device Taya Furmanski Albert Attia Advisor: Thomas Doyle, M.D. March 17, 2003.
Pipe flow analysis.
Checkpoint Presentation Shayer Chowdhury Project #3 Mentors: Dr. Gyusung Lee, Dr. Mija Lee.
Patent Ductus and Vascular Occlusion Devices Michelle Carlsen Elaine Isom Brad Klosterman Ornob Roy Advisor: Dr. Thomas Doyle.
Heat Transfer by Convection
SUGGESTED MINIMUM KNOWLEDGE OF FLUID MECHANICS AND FOR FE EXAM
Common Medical Procedures for Treating Varicose Veins.
Team Members: Lacey Halfen, Jessica Hause, Erin Main, Peter Strohm & Fan Wu Client: Orhan UnalAdvisor: Willis Tompkins Team Members: Lacey Halfen, Jessica.
Determine method of rapid prototyping or plastic extrusion to create prototype of true-to-scale catheter Determine optimal slot size without affecting.
Savannah LaPrad Brain AneurysmsBrain Aneurysms. The Basics ▪A brain aneurysm is a weak or thin spot within a blood vessel of the brain that balloons out.
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Special circulations, Coronary, Pulmonary…
Improving CABG Surgery
Unit 42: Heat Transfer and Combustion
Piyush Modi Assist.Prof
From: Improved Ease of Use Designs for Rapid Heart Cooling
Special circulations, Coronary, Pulmonary…
Improving Simulations in the Post Anesthesia Care Unit
Immobile Ocular Perfusion Pump
Condensers.
Devil physics The baddest class on campus AP Physics
Approximation of Percolation Thresholds
Design and Development of Steerable Catheter
Presentation transcript:

Project Definition The aim of this project was to design a steerable catheter, which would enable easier access to specific blood vessels. The design would be used in the Radiology Department for improved treatment of cerebral aneurysms in the brain. Additionally, a simulated arterial system was created for catheter testing and training.

Background Aneurysms are disorders that involve the localized widening of one or more blood vessels. It is estimated that 5% of the population has some type of aneurysm. There are no known ways to prevent aneurysms, but they are often treatable. The most common method used to treat an aneurysm is surgery. During surgery a catheter is inserted and guided into a specific blood vessel. The base of the aneurysm is closed off with clamps, sutures, coils, and other methods using catheters. Currently, catheter guidance techniques involve the use of various guide wires which can be very difficult and time consuming. The design of a steerable catheter would allow the surgeon to access hard to reach areas in less time.

Demands & Wishes zDemands yCatheter can turn up to 90° in any direction yCatheter diameter must be  1 mm in order to access arteries ranging in diameter from 2-3 mm yPerform within temperature range between 95°F and 105°F yPerform in various viscosity levels of the blood yPerform under various flow patterns and pulsatile natures of the blood yCatheter must not alter or harm the well being of the patient zWishes yCatheter should be relatively easy to handle and maneuver yPrice should be competitive with current catheters in the market

Calculations zWhat should the ratio of glycerol to water be to represent the viscosity of blood? Given:  blood  4cP, m  8 mol/kg, MW Glycerol = 92 g,  glycerol  1.1 g/cm 3 Solution: Volume of glycerol = (molality)(Molecular Weight)/(Density glycerol ) = Liters of glycerol/Liter of H 2 O zDetermination of Reynold’s Number (Ex. S.E.D. = 5): Given:  solution = 1.04 g/cm 3, Diam. = cm,  solution  4cP, Area = cm 2 Solution: Velocity (V) = Flow (Q)/ Area (A) = cm/sec Reynold’s Number (Re) = (  solution )(V)(D)/(  solution ) = 982…Laminar

Catheter Models z Model I consisted of a turn-wire threaded completely through the catheter and fastened to the end about in. down the outside of the catheter with silicon. z Model II is very similar to Model I except that the wire exits the catheter about 1 in. below the catheter tip where it is then fastened with silicon to the catheter head.

Catheter Models (cont.) z Model III followed the concept of Model II with the exception that the turn-wire floats freely outside the catheter to decrease the resistance between the wire and the catheter. To further this design, improvements must be done to guide the turn wire along the outside of the catheter. z Model IV* is currently under development, although proper materials are uncertain. The catheter design contains two types of tubing with varying stiffness connected by silicon. Again, a turn-wire is completely threaded through the catheter and attached with silicon to the catheter tip.The tube creating the catheter tip is more pliable than the other Suggestion from Dr. Bob Galloway

Catheter Models (cont.) z Model V will be created using Muscle-Wire technology. Muscle-Wire contracts when heated electrically past a threshold temperature. In this design, electrical wires attached to the Muscle-Wire run through the inside of the catheter. The Muscle-Wire is attached to the head of the catheter. Silicon will seal the head of the catheter to prevent liquid from entering.

Design Summary

Simulated Arterial System zOverview: yA closed-loop system, created from a reservoir, roller pump, and surgical tubing, allows the continual flow of a water and glycerol solution (providing Newtonian fluid characteristics) simulating blood within the arterial system. The model is approximately twice the size of the actual microvasculature (ID tubing = 6.3 mm). z Objectives: yTest prototypes of catheter designs yCreate an applicable learning device to further catheter insertion and guidance techniques* *Suggestion from Dr. Paul King

Uncertainties zCatheter Design yFeasibility of heating Muscle Wire in vivo yOptimal attachment positions of turn-wire on head of catheter yAppropriate materials for Model IV design z Arterial Model ySimilarity of surgical tubing in relation to actual arterial wall stiffness yLeakage at catheter insertion point yAccuracy of blood flow within cerebral vasculature

Future Work zFollow-up on uncertainties zContinue patent search zBuild and test additional prototypes zResearch the possibility of marketing the simulated arterial system for catheter training purposes zGRADUATE!