Learning, our way Exercise Water pipe, Pump and Cooling Tower Selection.

Slides:



Advertisements
Similar presentations
Proper Vent Sizing 4 Natural Draft Furnaces 4 Fan Assisted Furnace 4 Common Vent Systems.
Advertisements

Fluid Mechanics 07.
Copyright ⓒ 2008 All rights reserved LG Electronics Inc. Daikin VRV III vs LG MULTI V Plus II.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Example: Exercise (Pump)
Tutorial Excel and Equation Editor Given the following measurements of mass flow rate in a water pipe and the following properties and relationships: K=
Fluid Mechanics 06. Energy, Work and Power Work:- Work is force acting through a distance when the force is parallel to the direction of motion. Energy:-
Pump Basics. Centrifugal Pumps From the Center of a Circle RADIAL DIRECTION To the Outside of a Circle A machine for moving fluid by accelerating the.
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
STEAM CONDENSERS.
Lesson 26 CENTRIFUGAL PUMPS
Piping Systems.
Core Ag Engineering Principles – Session 1
1 CTC 450 Pumps Pumps
2006 Oct. 19 DES Project -- Vaidas Simaitis, University of Illinois1 DHE – Detector Head Electronics Monsoon 80mm Crate Heat Load.
Ice Pile Air Conditioning Joseph Cooper: Project Lead Kylie Rhoades, Clara Echavarria, Jonathon Locke, Alex Gee.
Work Distribution Analysis of I.C. Engine Cycles P M V Subbarao Professor Mechanical Engineering Department Find true Scope for Development….
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
Installed Gain as a Control Valve Sizing Criteria Jon Monsen, Ph.D., P.E.
Hydraulic Engineering
VRV III Product Selection Piping selection
Water piping design.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
FEASIBILITY OF COMPONENTS CLARA ECHAVARRIA & JONATHON LOCKE.
Cryogenic cavern in Asian site Conceptual design of the cryogenic system Layout of the cryogenic plant for site A & B New layout of the cryogenic system.
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Fluids - Dynamics Level 1 Physics. Fluid Flow So far, our discussion about fluids has been when they are at rest. We will Now talk about fluids that are.
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
Unit: V-Flow Through Pipes. Flow Through Pipes  Major Energy Losses - Darcy-Weisbach Formula - Chezy’s Formula  Minor Energy Losses -Sudden expansion.
Lesson 8 SECOND LAW OF THERMODYNAMICS
Hydraulic Kit (pump and tank) Pictures from prototype.
Conceptual Design Study - Cryogenic Requirements How to decide the layout of ILC cryogenic system Conceptual design of cryogenic system Layout of cryogenic.
IIT-Madras, Momentum Transfer: July 2005-Dec 2005.
AAE 450 – Spacecraft Design Sam Rodkey 1 Designing for Thermal Control Sam Rodkey February 14 th, 2005 Project Management Project Manager.
Lesson 23 HEAD LOSS DEFINE the terms head loss, frictional loss, and minor losses. DETERMINE friction factors for various flow situations using the Moody.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
Pressure-Enthalpy and the Variable Refrigerant Cycle
Page 1 MCQUAY DIGITAL SCROLL SYSTEM Unit & Piping Selection.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Background 1. Energy conservation equation If there is no friction.
Introduction to Energy Management
Hydraulics is defined as the study of fluid behavior, at rest and in motion Properly designed piping with sound hydraulics can: - Greatly reduce maintenance.
CE 3372 Water Systems Design
Page 1 AMDS Selection. Page 2 Contents Introduction Selection Consideration Selection Process Software Demonstration.
Water Management Water is an important natural resource that requires proper management. Appropriate flow rate, pressure, and water quality are necessary.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
CIBSE HCNW 28 August 2014 Modular boilers. Traditional or low-tech replacement boiler installation; Multiple boilers eg 2 no 66% of load for security.
RFQ Cooling Schemes and Instrumentation PXIE RFQ Fabrication Readiness Review LBNL – June 26, 2013 Andrew Lambert - Engineering Division Lawrence Berkeley.
N ATIONAL D IPLOMA M ECHANICAL AND E LECTRICAL S ERVICES C ONSTRUCTION Hot Water Pipe Sizing and Boiler Recovery Times.
Major loss in Ducts, Tubes and Pipes
8.2 OBJECTIVES  Describe the appearance of laminar flow and turbulent flow  State the relationship used to compute the Reynolds number  Identify the.
19-SEP-2012 «BE-RF-PM» Modelling of hydraulic system of CLIC prototype module type 0 Shoaib Azhar.
6.5 Recommended Velocity Of Flow In Pipe And Tubing.
First Law of Thermodynamics applied to Flow processes
EXERCISES Two water reservoirs are connected by a pipe 610m of 0.3m diameter, f’=0.038 and the flow produced by the difference in water surface elevations.
Troubleshooting a 556m Long Sand Slurry Pipeline
Design of Cold Water Networks
KINEMATICS 1. A nozzle is so shaped that the velocity of flow along the centre line changes linearly from 1.5 m/s to 15 m/s in a distance of m. Determine.
Chapter 4. Analysis of Flows in Pipes
Pumps and Lift Stations
Chapter 6 THE MECHANICAL ENERGY BALANCE.
MDS Selection.
TECHNICAL TRAINING 2007.
Line Sizing By Shardul Kulkarni.
50 m EML3015C Thermal-Fluid I Fall 2000 Homework 4
Fluid Mechanics Lectures 2nd year/2nd semister/ /Al-Mustansiriyah unv
Presentation transcript:

Learning, our way Exercise Water pipe, Pump and Cooling Tower Selection

Learning, our way Watercooled VRV Selection: VRV WII - Express Cooling Load per floor is 40 kW, Heat load 16.5 kW –10 HP VRV unit gives >130% connection ratio –20 HP VRV unit gives % connection ratio, Depending on piping length –30 HP VRV unit gives <66% connection ratio 20 Hp unit is selected

Learning, our way Cooling unit Selection Cooling tower, evaporative cooler or dry cooler? Approach: 8°C, mild climate. Europe, small scale installation (No large water purification installation needed) Type: Evaporative fluid coolers Brand Baltimore: Type VXI

Learning, our way Cooling mode: (VRV express) Total heating capacity available= 49.5W *4 Total Power Input at 98% connection ratio = 9.0 kW *4 Total rejected heat = 4 *( )= 234 kW Total water flow (= max water flow )= 96 * 2* 4 = 768 l/min = 12.8 l/s Range= EWC – LWC = rejected heat / (4.186 x water flow) =177.6 / (4,186 x 12,8)= 4,37°C EWC= cooling tower entering water temperature= ,4 = 34,4°C LWC= cooling tower leaving water temperature = 30 °C Approach = LWC – WBT = 30°C – 22°C = 8°C Calculations Evaporative Cooler Selection:

Learning, our way Selection Evaporator Determine the performance factor using the diagrams provided by Baltimore: Input: Range = 4.4 Approach = 8°C WBT = 22°C Output: Pf = 5

Learning, our way Evaporative cooler selection

Learning, our way

Cooling mode: ACCORDING TO DATABOOK is different?? A lot higher, 10 HP… Total heating capacity available= 56.7kW *4 Total Power Input at 98% connection ratio = 12.3kW *4 Total rejected heat = 4 *( )= kW Total water flow)= 96 * 2* 4 = 768 l/min = 12.8 l/s Range= EWC – LWC = rejected heat / (4.186 x water flow) = = 177.6/(4,186 x 12,8)= 4,4°C EWC= cooling tower entering water temperature= ,3 = 33,3°C LWC= cooling tower leaving water temperature = 30 °C Calculations Cooling tower Selection:

Learning, our way Heating mode: Total Heat capacity required= 63 kW *4 Total Power Input = 6 kW *4 Total injected heat = 4 *(63-6)= 228 kW Calculations Boiler Capacity:

Learning, our way Water piping: water flow rates Each VRV has as design waterflow –96 l/min per 10 Hp unit. Horizontal piping to indoor units: –2 x 96 l/min = 192 l/min Vertical parts: Different sections A, B, C, D –Secton A: Only 1 20 HP unit: 192 l/min (=3,2l/s) –Section B: 2x 20 HP unit : 384 l/min (=6,4l/s) –Section C: 3x 20 HP unit, 576 l/min (=9,6l/s) –Section D: 1x 10 HP Sub-unit, 96l/min (=1,6l/s) –Section E: 4x 20 HP unit: 768 l/min (=12,8l/s) Reverse Return Distriubution * * A B C D E A C B

Learning, our way Piping diameters Reccomendations: Pipe diameter (mm) Velocity range (m/s) ~ ~ ~2.1 Around 250.6~1.2 A B C D E

Learning, our way Reference Path: Take worse case: 3m C+B+C+horizontal: 3m A+B+C+horizontal Linear Head Loss Using Friction loss graph: Opposite effect of joints Comparable results! Part:Flow rate (l/s) Diameter (mm) Water velocity (m/s) Length (m) Pressure loss per meter (Pa/m)=10m H 2 O/m Total (mH 2 O) A ,52x ,91 B ,21 C ,53500,15 D ,92 x 1500,1 E , * * A B C D E A C B

Learning, our way Linear Head loss (Water piping selector) Reference Path: take worse case. 3m C+B+C+horizontal 3m A+B+C+horizontal:  Comparable (0,06 mH2O difference) Part:Flow rate (l/min) Diameter (mm) Water velocity (m/s) Length (m) Pressure loss per meter mH 2 O/m Total (mH 2 O) A ,52 X ,91 B ,21 C ,53500,15 D 96400,92 x 1500,1 E , ,18 * * A B C D E A C B

Learning, our way Water Pipe Design: Local Head losses Local friction losses: For 1 water route: –3 branches “Straight Trough” -2 x “Trough Branch” connection on main line (2 for each 10 HP unit, speed ) -2 x “Trough Branch” Joint on indoor piping -2x 3 elbow joints on indoor piping Straight line friction losses: –4 x 3 m vertical piping, –2 x 3 m indoor piping * * A B C D E A C B

Learning, our way * * A B C D E A C B Local Head loss: Blue path T joints “Straight Trough” E to C C to B B to A. Partial head loss Ht Location: Number ON 1 water path Equivalent piping length (m) Pressure loss / m (mmH 2 O/m) Pressure loss (mH2O) Elbows on A 2* * Elbows on D 2*12 * Elbows on E 22 * 1, T-joints Staight-tru (on main line) 31, T-joints Tru Branch (on main line) T-joints Tru Branch (on horizontal line) T joint “Trough Branch” A to E B to A A to C E to C C to B C to E vs Red path name Diam (mm) A 50 B 65 C 80 D 40 E Total: +0.20

Learning, our way Piping design – pump selection properties H = H a + H f + H t + H k H t = Linear Head loss = 1.55 mH 2 O H a = Actual head (m H 2 O) = 0 H t = Partial friction loss = 2,23 m H 2 O H k = Internal friction loss = 2,7 mH 2 O 1 x 1 VRV 10 HP unit, at 96 l/min H k2 = Given, 5 mH 2 O Total head loss= 11,48 mH 2 O at a flow rate of 768 l/min 46 m 3 /hr mH 2 O

Learning, our way Water piping design: Pump Pre-selection LRC 406

Learning, our way Pump Selection: Pump /3 or above