Www.hvac.vn Submersible Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.

Slides:



Advertisements
Similar presentations
Water & Wastewater Construction Back Forward Wastewater Treatment Plant and Pump Station Improvements, Haverhill, MA.
Advertisements

Preferred Utilities Manufacturing Corp South Street Danbury CT Fuel Oil Handling Systems Tank Gauges and Leak Detection.
Visit Us At Booth #306 J2 Engineering, Inc. J2 provides Construction and Environmental Services and is a verified Service-Disabled Veteran-Owned Small.
Pipes Single Wall Pipes Double Wall Pipes
Thermostats The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
XB5R range Wireless & Batteryless Automatic doors offer.
HVAC Air Flow Measurement The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Open Channel Flow Panel Meters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Product Line Overview Company Overview  Incorporated in 1983  Developed and patented first Electronic Cylinder Scale – Model.
Petroleum Equipment Institute
Training Course Industrial Solutions. You Can Measure the Benefits… 2 Industrial Solutions  Water and waste  Food and beverage  Chemical  Fuel and.
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
1.  Introduction  Categories/Kinds of Pressure Sensing Accessories  Purpose  References 2.
Mechanical AST5300 is a wet / wet differential pressure transmitter Compatible with liquids or gases on both the high pressure and low pressure process.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
Mechanical for Oil Heat
Submersible Seal Top Down DP Level Assembly. DP Level Solution for Top-Down Level Measurement Applications Challenge: Many tanks go un-instrumented in.
Chapter One Electrical Design and Component Basics.
Water Level loggers Vented vs Absolute. Definitions Absolute: Measures total pressure (weight) above the sensor. Atmospheric pressure must be removed.
Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by B. J. Benton United Pump and Controls, Inc.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
Endura pH TBX587 Retractable Sensor
Control System Instrumentation
SETA Water treatment plant maintenance
Chapter 37 Pipeline Construction. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Explain the.
TRENTON Casing Filler Presentation
About Us  We are a group of Mechanical Engineers specialized in Construction & Engineering Services.  Our mission is to provide highest quality of construction.
Section 4 Ancillary Equipment Section 4 Ancillary Equipment Definition Dispensers & Under Dispenser Containment Vapor Recovery Drop Tube & Fill Port.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Gas Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Handheld Digital Manometers The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Modern electronics continue to be placed in denser packaging and smaller enclosures, often causing overheating problems Moisture and airborne dust, oil,
Miscellaneous Test Equipment Combustion, Tachometers, Hygrometers The materials included in this compilation are for the use of Dwyer Instruments,
Ultrasonic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Powder & Bulk Level Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Temperature Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Vibration Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Pressure Transmitters and Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential.
Air Handler Demonstration The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Staying in Compliance Dispensing Equipment Spill/Overfill Presented by Travis Benton United Pump and Controls, Inc.
Flow Technology Overview The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
©2005 Armstrong International, Inc. Stainless Steel Sump Ejector.
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
BY- NAGENDRA PRATAP SINGH (TECHNICAL TRAINING ANALYST)
SAL COLLEGE OF ENGINEERING AHMEDABAD LIQUID LEVEL MEASUREMENT
PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
CiDRA - Power Generation Applications
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
Grounding the Electrical System
Signal Transmission and Conversion, Test Review - Agenda
Copyright SwissFlow B.V.
USonic-R™ Remote 2-Channel System
Grounding the Electrical System
Industrial Instrumentation: Transmitters
Module – Groundwater Level Measurement
ANALYSERS & INSTRUMENTS DEPT. OPASTOP GP2001H
Fuel Supply System Chapter 21 Lesson 1.
Pressure Level Sensor OTT PLS
Control System Instrumentation
Presentation transcript:

Submersible Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.

Overview MBLTFBLTSBLTPBLT

Technology Measure the height of liquid above the position in the tank referenced to atmospheric pressure Pressure on sensor can be related to height of liquid. Piezoresistive sensing element, encased in a 316 SS housing Piezoresistive – describes a material whose resistance changes as a function of mechanical strain applied

FBLT Introduction FBLT Submersible Level Transmitter Flush Diaphragm Design Purchase by Level Range, Cable Type and Length

FBLT Specifications Wetted Materials: Body: 316 SS; Cable: Polyether polyurethane or ETFE; Diaphragm: PTFE coated FKM Accuracy: ±0.25% FS Electrical Protection: Surge/lightning protected per EN , Class 5

FBLT Product Features Flush, PTFE coated diaphragm Low profile narrow design for tight applications such as through pipe installations Non-clogging/non-fouling for particulates and sludge PTFE is non-stick for no buildup on the sensor Gel fill will not leak even with small holes in the diaphragm. Competitors use oil.

MBLT – Introduction Miniature Submersible Level Transmitter for well and borehole applications Vented for barometric pressure compensation Purchase by accuracy, range, and cable length

MBLT - Specifications Wetted Materials: Body and nose: 316 SS Cable: Polyether polyurethane or ETFE Seals: Fluoroelastomer Accuracy: ±0.25% FS (10; w.c. range is ±0.30%FS) or ±0.10% FS Output: 2-wire 4-20 mA Electrical Protection: Surge/lightning protected per EN , Class 5 Agency Approval: CE

MBLT - Features 0.63” diameter for bore-hole and well applications 316 SS tapered body and nose cap Tapered gland- does not snag Vent is covered with maintenance-free filter protecting sensor Level Ranges: 1.4 to 210 m w.c.

PBLT2/PBLTX - Introduction Submersible Level Transmitter for sludge pit and slurry applications Vented for barometric pressure compensation Purchase by range, cable length, and cable type

PBLT2/PBLTX - Specifications Accuracy: ±0.25% full-scale Output Signal: 4 to 20 mA DC, two wire Sensor Housing: 316 SS Cable: Polyurethane or ETFE Ranges: 3.52 to 100 meters w.c. Agency Approvals: PBLTX: CE, cUL intrinsically safe

PBLT2/PBLTX - Features Excellent chemical compatibility with 316 construction and ETFE cable Lightning and surge protection on PBLT2 models Maintenance free vent filter Durable cage protects diaphragm from rocks and debris. Large diameter, non-clogging, damage resistant, 316 SS diaphragm seal

SBLT2/SBLTX - Introduction Submersible level transmitter with PVC nose cap Purchase by Level Range, Cable Type and Length

SBLT2/SBLTX- Specifications Sensor Housing: 316 SS Accuracy: ±0.25% of full-scale Output Signal: 4 to 20 mA DC, 2-wire Cable: Polyurethane or ETFE Bullet nose: PVC Level Ranges: 3.52 to 240 meters w.c.

SBLT2/SBLTX - Features Bullet nose design protects the diaphragm from damage Excellent chemical compatibility Lightning and surge protection on SBLT2 models Maintenance free vent filter UL approved intrinsically safe on SBLTX models Slimmer design for tight applications

Applications Wastewater Level Monitoring Pump/Lift Stations

Applications Liquid Tanks Fuel Water Chemical Storage

Applications Water Treatment Plant Head Works (Influent) Settling Basins Aeration Basins

Applications Stilling Wells Used to decrease turbulence for level measurement FBLT fits in smaller diameter stilling wells

Applications Industrial Wastewater Heat Recovery Water Reuse Sump Level Monitoring/Pump Control

Applications Well monitoring Ground water monitoring

Applications Systems Manufacturers Pump Control Panel Manufactures Packaged Lift Stations Manufactures