Water Level loggers Vented vs Absolute. Definitions Absolute: Measures total pressure (weight) above the sensor. Atmospheric pressure must be removed.

Similar presentations


Presentation on theme: "Water Level loggers Vented vs Absolute. Definitions Absolute: Measures total pressure (weight) above the sensor. Atmospheric pressure must be removed."— Presentation transcript:

1 Water Level loggers Vented vs Absolute

2 Definitions Absolute: Measures total pressure (weight) above the sensor. Atmospheric pressure must be removed from this value to reveal actual water pressure (water column). Vented: Measures only water pressure above sensor. Atmospheric vent accounts for atmospheric pressure.

3 The mystery of barometric compensation Pressure in cmH ₂ O Level logger: 1500cmH ₂ O – Baro: 1000cmH ₂ O = 500cmH ₂ O = 0.5m above the pressure sensor ALWAYS take a manual dip measurement!

4 How do they work? 5cm 0 ------------------------------------------------------------------------------ ----------------------- --------------------

5 ----------------------------------------------------------------------------------------- --------------------------------------------------------------------------------------- ---------------------------------------- Baro Absolute 2 x Errors

6 Pressure ranges 1m -------------------------------------------------------------------------------------- 10m -------------------------------------------------------------------------------------- 30m -------------------------------------------------------------------------------------- Sensitivity varies with manufacturer. Accuracy based on full scale.

7 One size does not fit all….. High Accuracy? 100m range? Low maintenance? Easy to deploy? Multiple interface options? Long battery life? Low cost? 120 Ub Unobtanium

8 If vented loggers are so good, why would I choose not to use them? Vented cable: installation, vandalism, weather protection, tailor length cables/re-deployment Cost User interface Maintenance

9 When should I use a vented logger? Critical data External logger or telemetry? Single installation?

10 Why would I choose to use an absolute logger? Maintenance free Easy deployment Low cost, particularly for multiple installations Purpose made intuitive interfaces Easy re-deployment/Versatility Discrete

11 What else to consider? Site access? Equipment placement (above and below water) Environmental/human risk? Return visiting? GPRS signal? (NOT THE SAME AS CALL SIGNAL) Critical data? Expected fluctuation? Other parameters? Budget?

12 Conclusion Is vented better than absolute? … Not necessarily Consider your application carefully