Basic Operation of the Scott Mini-SA Portable Gas Detector.

Slides:



Advertisements
Similar presentations
January 2012International Medcom, Inc How to Use the Radalert 100.
Advertisements

January 2012International Medcom, Inc How to Use the Inspector Alert.
Computer terms you should know at the end of Kindergarten,
How to use the NEC projector Its easy! Really!. How to use the NEC projector IMPORTANT-make sure you have reserved the equipment (projector and/or laptop).
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
SOLARIS 3-GAS METER Complete operation of Solaris multi-gas meter can be found on the LAFD Ethernet.
DP-IR Detecto-Pak Infrared
MS Access 2003 Tutorial By: Juan GUANTENG!!! Y7. Step 1 Launch the Microsoft Access 2003 program. This can be done by clicking an icon on the desktop.
Bump-test and Calibration Procedures
Using the MiniRAE 3000.
Components: Sansa Clip Mp3, earbuds, USB cable, Quick Start Guide.
Using the Qwizdom Remotes 1.Press and hold the MENU button to turn ON the remote. The double-arrow key is the “send” key. 1.Session ID: , press “send”
Remote set-up instructions Life is meant to be interactive!
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
Refresher Instruction Guide Strategic Planning and Assessment Module
LogTag Training January 2015
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
M100 M100 Overview Preparation & Testing. M100 Overview  The M100 is a computerized tabulator that optically reads then counts and totals specially designed.
This is OK! The Clicker is in “Power Save” Also called “Sleep Mode”
ECATS “The Honeywell Web-based Corrective Action Solution” CAR Process Last Revised: August 19 th 2008 Honeywell Confidential & Proprietary.
Familiarization and Operation
Clean Air Box Usage & Care CABs RAMs CO Monitors.
MSA - ALTAIR 4X Gas Meter.
Computer Basics Dayton Metro Library Place photo here May 20, 2015.
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
AccuMax Multi-Point Injection Mechanics
Altair® 5X MultiGas Detector Altair® 5X MultiGas Detector The ALTAIR 5X MultiGas Detector is to be used when performing a hazard assessment.
Navigation 1 GPS for ICS Navigation 1 Objectives:  Set up a Garmin GPS III Plus for inputting coordinates.  Manually enter three sets of coordinates.
After Receiving this error code, Follow these steps to correct the problem… Click for next slide.
May 2007 North Zone – Communications Bendix King EPH and GPH Portable Radios North Zone Communications Committee.
Compliance Assist Refresher Instruction Guide Adding or Editing Unit/College Strategic Goals.
M40M Multi-Gas Monitor. Checking instrument: A. Checking instrument: 1.Turn the instrument on by pressing the power button on the control face panel for.
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
[Course Name] An i>clicker remote is required for this course. You can purchase it through the bookstore. The clicker/a coupon may be packaged with your.
International Medcom How to Use the Radalert 50 March 2005 International Medcom
STEP 1: Determining the exact image width STEP 1: Determining the exact image width Position of X-ray Filter Position of X-ray Filter STEP 5: Crop Extra.
You will find applications that are installed on the computer. Go to Start – Programs (depending on view Start – All Programs). All applications installed.
PN: TM rev:3 Administration Training. PN: TM rev:3 Course Overview Logging On Menu Screens »Edit Functions Options Configuration Users »View.
Follow-Me charge stage coordination and what to expect out of multiple charge controllers.
Connecting and Configuring Clickers. InterWrite PRS - Clicker 2-line LCD Display See data entered Confirmation answer received Variety of question types.
WINDOWS Part 1 – Start Up Basics
Macromedia Dreamweaver 4.0 INTERFACE This presentation will run automatically.
MSA Five Star 4-Gas Monitor Air Monitoring Instrumentation.
Intuitive Programming System For The Mill
AGENDA - TASK, CONDITIONS, STANDARDS - PACKAGE AND COMPONENTS - FRONT PANEL DISPLAY - ATTRIBUTES - USING THE RADIO - BATTERY OPERATIONS - HEADSET ILLISTRATION.
ResponseCard XR User Data. Press the MENU button ResponseCard XR.
ResponseCard XR User Data Version 1.0 ®. Press the MENU button. ResponseCard XR.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
How to use the scanner This process will teach you how to use the scanner Press yellow button to turn power on In the top left corner tap “start”
Detecting Instruments (For Contest Work Only) MSA Passport Personal Alarm.
FAC calibration for wheel balancer Editor: Song Zhi C HECKED : Li Chuanhong Version : A1001 Date : The factory calibration program can be suitable.
Click the pictures to advance to next slide Use the left arrow to go back.
INTRODUCTION TO LFG INSTRUMENTS. SENSORY THEORY CATALYTIC - PPM AND 0 TO 10% GAS (O 2 DEPENDENT TO 2%) THERMAL - 10% TO 100% GAS BY VOLUME (NON O 2 DEPENDENT)
How to save the appeal form before submission Click to continue.
PRO OX ® -100 Kit PROGRAMMABLE DIGITAL OXYGEN MONITOR US & FOREIGN PATENTS ISSUED & PENDING STATE-OF-THE-ART TECHNOLOGY FOR PRECISE OXYGEN MONITORING MADE.
CB430 Display Basics. Display Introduction LCD Screen Data Card Door/Slot Main Hardkeys Hardkeys / Softkeys.
FrontPage & Web Page Design. Starting FrontPage Click on the FrontPage icon in the task bar at the bottom of the screen or Locate it from the programs.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
How to connect your brick
ReverseTap S/W MANUAL.
Automatic Test Station for GasAlertClip Extreme Portable H2S Monitors
G450 and G460 battery pack maintenance
Laser 3000™ Operating Instructions
Proxies Granting proxy authorization enables another provider to access your Inbox Documents and handle them for you. Your proxy can review, sign, refuse,
C140 Navigation System Upgrade Manual
Two methods to observe tutorial
Two methods to observe tutorial
C140 Navigation System Upgrade Manual
Presentation transcript:

Basic Operation of the Scott Mini-SA Portable Gas Detector

Scott Mini-SA Portable Gas Detector

To Turn on the Unit : Press either of the two gray buttons on the bottom of the unit. The unit will beep three times and initialize itself.

The screen will show a PPM CO display, a battery strength icon, and a menu selector icon. CO PPM Display Battery Strength Icon Menu

Alarming : The unit alarms for carbon monoxide only!! It will alarm for short term acute exposure and longer term chronic exposure. The alarm limits are preset at the factory. They can be changed by using the menu function but this should be done by administrative staff only. Do not make changes to settings without permission!!!!!!!!!

To Zero Calibrate the Unit: The unit should be auto zero calibrated in fresh air prior to entering a possible CO atmosphere. To auto zero calibrate, press the button below the menu icon. Menu Button

Then press the button below the auto zero display. The unit will auto zero calibrate in 3 seconds. Auto Zero Display

To Turn off the Unit: If the screen has blanked into the power saving mode, press either button to refresh the screen. To turn off the unit, hold both bottom buttons simultaneously until the unit beeps 3 times and a display appears asking if you want to turn off the unit.

Press the button under the Yes display.

Replacing Batteries : The unit requires two AAA batteries. Rechargeable batteries should not be used. To replace batteries, access the Phillips screw through the metal clip-on attachment. Loosen the screw and remove the clip-on attachment and the battery door.

Warnings: The unit will display problems on the screen, such as a warning that the unit needs gas recalibration. If problems are displayed, take the unit out of service and complete an A&E Storage: The unit should be left in its plastic bag and storage box in the “off” position. A complete users’ manual is available in each station.

Review PFD SOG 2-8 for supplemental information