Introduction ► Scope:- Service Diagnostics Routines can use for XXL, Side by Side products with STEALTH user interface with single evaporator fan product.

Slides:



Advertisements
Similar presentations
ELECTROLUX REFRIGERATOR
Advertisements

Tuono Dashboard and immobilizer new features 1 2 Dashboard
Crown XTi Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display Updating.
IGCSE ICT Control Systems.
Page 1 Updated by: Yap Boon Thiam Technical Engineer Date: 09/5/2012.
Crown CDi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Operating Functions.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
Digital Non-Programmable Thermostat. Digital screen Setpoint indicator- Appears when the Setpoint temperature is displayed Low battery warning Temperature.
VIDEOCON SBS REF. Display panel Water dispenser Castors REF Compartment Door handle FRZ Compartment.
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
University of Maryland Center for Environmental Science Chesapeake Biological Laboratory IP Phone Training.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
Refrigeration Flow Control
Projector Controllers
In this presentation you will:
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
AccuMax Single Point Injection Operation (See Installation and Operation Manual for detailed instructions)
Advanced Tool Management Information Module Advanced Tool Management Information Module.
Self-Contained Particulate Filter Filter 3 Presenters: Ian Gray, Kyhia Bostic Demo Given by: Nathan Sullivan.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
Product Introduction.
AccuMax Multi-Point Injection Mechanics
CAFS On-Line Orientation Montgomery County Fire & Rescue Service Operating the CAFS Controllers.
M40M Multi-Gas Monitor. Checking instrument: A. Checking instrument: 1.Turn the instrument on by pressing the power button on the control face panel for.
Copyright © 2014 Delmar, Cengage Learning APAD/ACPU A/C Control Systems Instructor Name: (Your Name) 11 CHAPTER.
2-Stage Heat Pump Defrost Options Defrost options: –30, 60, 90, 120 or Auto (Infinity/Evolution only) Defrost initiate temp: 32° F Defrost terminate temp:
AS ICT.  Have an understanding of how organizations use ICT.  Be able to describe a number of uses, giving the hardware and software requirements. 
Settings & Adjustments. Settings & Adjustments.
Wireless Remote Controller (MR-AH01/BH01) HQ SE.  On/Off control  Air flow control  Temperature setting  Filter reset  Louver Control  Simple ON/OFF.
Introduction to Robo Pro
GCS 300 System Operation Application – Level 1.
Forging new generations of engineers
Khaled A. Al-Utaibi  The Push Button  Interfacing Push Buttons to Arduino  Programming Digital Inputs  Working with “Bouncy”
Operation Sabbath Mode - SELECT PROGRAM - Lights, alarms and fans Normal Sabbath Overview.
Automated Equipment LLC
8279 KEYBOARD AND DISPLAY INTERFACING
1. Enter service mode and scroll to the Calibrate menu option What is Rider Calibration? This feature enables a rider to calibrate the Watt sensor before.
Asttraining.com Scan Procedures for Ford EEC-V OBD II Systems.
TECHNICAL TRAINING INVERTER-Y
WHIRLPOOL STEAM WASHER Presented by: Rick Kuemin, MSA Training Director Brought to you by:
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
msa samsung front load washer wf9100
WS50(Stratacache) Software updating guide (By Using USB)
Service Section Technical Training December 2005.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
1 i-Pendant for the R-J3iC & R-30iA Controllers ArcTool Version (GMAW) i Pendant New.
NN-CS596S Steam Microwave Oven. NN-CS596S Oven Specification.
Using your ENA Connect Phone Polycom IP 321/331/335.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
Service Section Technical Training. Sequential Controller SQ 1.0.
KM SERIES VENDING MACHINES OPERATION MANUAL. ARM Main board & Driver Board DRIVING BOARD MAIN BOARD.
Coffee Dispenser Set Up and Operation. Set up and Operation Start Up following installation Assuming all installation requirements have been met and the.
2013 CHIGO Product CHIGO CMV VRF Control System.
shift to the Test Mode (Forced Operation).
Automotive Heating And Air Conditioning
"This document can not be used without Samsung's authorization"
Automotive Heating And Air Conditioning
Store Multiple Results?
Wireless 4 Buttons Touch Panel
Wireless 3 Buttons Touch Panel
Commercial Stainless Steel Freezers
Digital Chart Recorder Operation
Resetting and long beep test for PCB without digital display
2. ATP INITIALIZATION PLACE ATP SWITCH TO “1” OR “NORMAL” POSITION A
Presentation transcript:

Introduction ► Scope:- Service Diagnostics Routines can use for XXL, Side by Side products with STEALTH user interface with single evaporator fan product. ► Objective:- This routine is capable of controlling the product Loads facilitating service. In some cases is also possible to inform the result of the current status of the load being tested.

Normal mode ► Service mode can be entered in Normal mode only (when cooling is ON). ► The following steps to be skipped for SN33, SN34, and SMX33 Step 5, Step 10, Step 12, step 14, Step 28, Step 30 Step 5, Step 10, Step 12, step 14, Step 28, Step 30 ► The following steps to be skipped for SN28, SL4 Step 5, Step 10, Step 12, step 14, Step 15, Step 19,Step 28, Step 29, Step 30 Step 5, Step 10, Step 12, step 14, Step 15, Step 19,Step 28, Step 29, Step 30 ► Door Ajar shall not be activated during service mode. ► Sleep mode is not allowed in Service mode. ► Cooling Off key combination is not allowed to toggle in service mode. ► Exiting service mode will produce DISENGAGE chime with Normal menu on UI.

Service Mode Access Method ► To enable Service Diagnostic Routine,Press and hold SW1 & SW2 for 3 second. 3 ->2->1 countdown will start on the UI,with single key press beep. 3 ->2->1 countdown will start on the UI,with single key press beep. ► During the 3, 2, 1 count down, If ice or water pad is pressed, it cancels the count down and no dispensing is permitted.”3” blinks 3 times with “invalid” chime 3 times, and user has to release pad and press Service mode key combination again to start it over. ► During the 3,2,1 count down, pressing any other key on UI or releasing Service mode key combination (before 3secs) cancels the count down and “3” blinks 3 times along with “INVALID” chime 3 times and user has to release all the pad which are pressing and start it over. ► Note: - The blinking and chimes are synchronized so that the moment 3 blinks, the chime shall be produced.

Service Mode ► Entering the service key combination shall activate the service mode as shown in above screen and produce ENGAGE chime.

Service Mode Navigation Method (Dual pad, Single pad/Non-Dispense) ► SW4 is used for step number decrement.SW5 is used for step number increment ► Holding down either button (SW4/SW5) for two seconds will cause the steps to decrement/increment steps numbers accordingly at the rate of 2 steps per second. ► If the Last Step is reached, Increasing the step shall return to the First Step ► If the First Step is reached, Decreasing the step shall return to the Last step ► SW3 key is used as the Change Setting Key. It is used to toggle the load which is tested therefore change the step setting information. ► If any other key / pad is pressed in service mode (except for the specified steps), the pad / key press will be ignored, no chimes shall be produced while pad / key is pressed..

► For products with only 2 Digits available, in order to accomplish the 3 digits requirements in some steps, digits 1 and 2 will be displayed for two seconds, followed by digit 3 and a dash for two seconds (dash will signify the end of the number). For products with 3 Digits available the information shall be displayed using 3 digits. ► Only two digits needed to display production software version and six digits will be needed. This could be accomplished by cycling between digit pairs major revision, minor revision, and test revision. Each digit pair shall be displayed for 2 seconds on the 2 digits display information and shall have 1 second blank time in between each each sequence (test revision & major revision); ► The 2 digits and 3 digits display information shall never appear at the same time. When one is active the other shall be blanked; ► For each step, only the load(s) being tested on the Step shall be turned ON (case needed). Exiting each Step, the load(s) turned on in the Step shall be turned OFF

User Interface Display information ► Press SW5 to display step number 1 Step Componen t ActionDisplay 1FC Thermistor Read the current temperature of the FC thermistor from Gemini Flash and compare this value. This information shall be Dynamically update (every 1 second). Value Read (VR):  COLD_LOWER_LIMIT  VR  HOT_UPPER_LIMIT  Pass  VR > HOT_UPPER_LIMIT  Short  VR< COLD_LOWER_LIMIT  Open 01=Pass, 02=Open, 03=Short Continued….

► Short ► Open ► Pass

2RC Thermistor Read the current temperature of the RC thermistor from Gemini Flash and compare this value. This information shall be Dynamically update (every 1 second). Value Read (VR):  COLD_LOWER_LIMIT  VR  HOT_UPPER_LIMIT  Pass  VR > HOT_UPPER_LIMIT  Short  VR< COLD_LOWER_LIMIT  Open 01=Pass, 02=Open, 03=Short StepComponentActionDisplay ► Press SW5 to display step number 2 Continued…. StepComponentActionDisplay

► Short ► Open ► Pass

► Press SW5 to display step number 3 3Evaporator fan motor and air baffle motor  Turn on the Evaporator Fan and monitor the Air Baffle feedback. For products with variable speed evaporator fan, the speed shall be set to 3000 rpm during this step. 01 = Fan ON/Air baffle Open 02 = Fan ON/Air baffle Closed (The display info is only available for air baffles motors with feedback)…. StepComponentActionDisplay Continued….

► Fan ON/Air baffle Open ► Fan ON/Air baffle Closed

4Compressor and condenser fan motor (non-VCC models) OR Condenser fan motor (VCC models) Control the Compressor and Condenser Fan Motor using the Change Setting keys. Notes: The Compressor shall be turned ON only when the Compressor in API 106 is set for “BASIC 1”. The Condenser Fan shall be turned ON only when the Condenser Fan in API 106 is set for “BASIC_1”. 01 = ON, 02 = OFF StepComponentActionDisplay ► Press SW5 to display step number 4 Continued…. SW3 key is used as the Change Setting Key to toggle the load

► Compressor ON ► Compressor OFF

6Defrost heater/Bimetal Switch on the Defrost Heater, wait 0.5 seconds and read the status of the bimetal. Blank = Until get a valid reading, 01 = bimetal closed, 02 = bimetal open StepComponentActionDisplay ► Press SW5 to display step number 6 Continued…. ► Blank Until get a valid reading,

► Bimetal closed ► Bimetal open

7Defrost modeSet the Defrost Mode using the Change Setting keys. This value shall be stored on EEPROM (in the next Power-up the Defrost Mode shall be initialized according this setting) 01 = ADC ON, 02 = Basic Mode ON (8 hour timer) StepComponentActionDisplay ► Press SW5 to display step number 7 Continued…. SW3 key is used as the Change Setting Key to toggle the load

► ADC ON ► Basic Mode ON (8 hour timer) Continued….

8All UI indicatorsLight all Led indicators and IconsAll Indicators ON StepComponentActionDisplay ► Press SW5 to display step number 8 ► All Indicators ON

9UI Pad and Button Test Read the UI Pads and Buttons. This information shall be updated every time that a new action is detected. If the Navigation Key is pressed, the UI shall switch to the next / previous step and the Switch number shall not be displayed. If the Change Setting Key is pressed the UI shall show the switch number. 2 digits available Digit 1: Blank = No switch is being pressed 1 = SW1 is being pressed 2 = SW2 is being pressed 3 = SW3 is being pressed` 6 = SW6 is being pressed * Note :- SW4 & SW5 IS USED FOR NAVIGATION.SW4 & SW5 is not displayed. Digit 2: Blank = No Pad is being pressed 1 = Ice Pad is being pressed 2 = Water Pad/Front fill is being pressed 3 = Ice and Water Pad are being pressed * Note:- Water pad( 2) is not applicable for single pad applications variants without front fill feature. * Note : Non-Dispenser variants, 1,2,3 are not applicable. Notes: when check for button, do not press any pad at the same time while a button is pressed. Likewise, when check for pads, do not press any button at the same time while a pad is pressed. StepComponentActionDisplay Continued….

► No switch and No Pad is being pressed ► Press SW5 to display step number 9 ► SW1 is being pressed Continued….

► SW2 is being pressed ► SW3 is being pressed ► SW4 is being pressed * Note :- SW4 & SW5 IS USED FOR NAVIGATION.SW4 & SW5 is not displayed.

► SW5 is being pressed ► SW6 is being pressed ► ICE Pad is pressed Continued….

► Water Pad/Front fill is being pressed ► Ice and Water Pad are being pressed * Note:- Water pad( 2) is not applicable for single pad applications variants without front fill feature. * Note : Non-Dispenser variants, 1,2,3 are not applicable.

11Dispenser Lighting Every key press(SW3) shall turn OFF(0%)  ON(100%)  1/2(dim) 50%-- > OFF Blank StepComponentActionDisplay ► Blank ► Press SW5 to display step number 11 Continued…. SW3 key is used as the Change Setting Key to toggle the load

StepComponentActionDisplay 13Dispenser Housing Heater Status Control the Dispenser Housing Heater using the Change Setting key(toggle between On and Off) 01 = ON, 02 = OFF ► Press SW5 to display step number 13 ► Dispenser Housing Heater ON Continued…. SW3 key is used as the Change Setting Key to toggle the load

► Dispenser Housing Heater Off

StepComponentActionDisplay ► Press SW5 to display step number 15 ► BIN_FULL_OR_N OT_PRESENT 15Ice Level Sensor (LV-IDI) Reads the Ice Bin Status01 = BIN_FULL_OR_NOT_PRESENT 02 = BIN_NOT_FULL_AND_PRESENT Continued….

► BIN_NOT_FULL_A ND_PRESENT

16RC Door Switch Input Reads the RC Door Switch Status. This information shall be Dynamically update (every 1 second). 01=Door open, 02=Door closed StepComponentActionDisplay ► Press SW5 to display step number 16 ► RC Door open Continued….

► RC Door Close

17FC Door Switch Input Reads the FC Door Switch Status. This information shall be Dynamically update (every 1 second). 01=Door open, 02=Door closed StepComponentActionDisplay ► Press SW5 to display step number 17 ► FC Door open Continued….

► FC Door Close

18Ice Door MotorControl the Ice Door Motor using the Ice Pad as if in normal operation:  Ice Pad Pressed  Ice Door open;  Ice Pad Released  After the Ice Door Motor Delay, the Ice Door shall be closed; 01=Closed, 02=Opening 03=Open 04= Closing StepComponentActionDisplay ► Press SW5 to display step number 18 Continued…. * Note:-Press Ice pad to control the Ice door motor status

► ICE Door Closed ► ICE Door Opening Continued….

► Ice door Open ► Ice door Closing

19Fill tube heater status, Control the Fill tube Heater using the Change Setting key(toggle between On and Off). 01 = ON, 02 = OFF StepComponentActionDisplay ► Press SW5 to display step number 19 Continued…. ► Fill Tube Heater ON SW3 key is used as the Change Setting Key to toggle the load

► Fill Tube Heater Off

20Water filter Usage Rating Reads on EEPROM, when the filter needs to be replaced (e.g., 048 gallons) 000 to 999 (gallons) ** StepComponentActionDisplay ► Press SW5 to display step number 20 Continued…. ► Water filter usage

21Water filter Time Rating Reads on EEPROM, when the filter needs to be replaced (e.g.,003 days) 000 to 999 (days) ** StepComponentActionDisplay ► Press SW5 to display step number 21 Continued…. ► Water filter Time

22Water Filter UsageReads the current Water Filter Usage (since last reset) 000 to 999 (gallons) ** StepComponentActionDisplay ► Press SW5 to display step number 22 Continued…. ► Water filter Usage

23Water Filter Time (since last reset) Reads the current Water Filter Time (since last reset) 000 to 999 (days) *** StepComponentActionDisplay ► Press SW5 to display step number 23 Continued…. ► Water filter Time

24Water Filter ResetsReads on EEPROM how many times the Water Filter was reset 000 to 999 (number of resets) ** StepComponentActionDisplay Continued…. ► No. of Water filter Reset ► Press SW5 to display step number 24

► No of Water filter Reset

25Water dispensing and icemaker fill test  Service tech simulate a icemaker water fill, then the ice maker will show icemaker fill information.  Pressing the Water Pad will initiate the water dispense; Digit 1 : 0 = Icemaker Fill OFF 1 = Icemaker Fill ON Digit 2: 0 = Water Dispensing Valve Off 1 = Water Dispensing Valve ON StepComponentActionDisplay Continued…. ► ICE Maker Fill Off ► Water Dispensing Valve Off ► Press SW5 to display step number 25

► ICE Maker Fill Off ► Water Dispensing Valve ON ► ICE Maker Fill ON ► Water Dispensing Valve Off ► ICE Maker Fill ON ► Water Dispensing Valve ON

26Product Control Board SW Version Reads the Product Control Board (e.g., Gemini Flash) SW version (e.g., ) XX XX XX StepComponentActionDisplay Continued…. ► Product Control Board SW Version ► Press SW5 to display step number 26

► Product Control Board SW Version

27Dispenser UI Control SW Version Reads the Dispenser UI Control SW Version (e.g., ) XX XX XX StepComponentActionDisplay Continued…. ► Dispenser UI Control SW Version ► Press SW5 to display step number 27

► Dispenser UI Control SW Version

29Low Voltage IDI SW Version, Reads the LV-IDI SW Version (e.g., ) XX XX XX StepComponentActionDisplay Continued…. ► Low Voltage IDI SW Version, ► Press SW5 to display step number 29

► Low Voltage IDI SW Version,