1 2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)

2 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner Check Valves Flow Meter

3 3 Water Tank Water Pump Flowmeter Line Strainer Foam Tank Electronic Direct Injection Proportioner Check Valves Multiple Discharges 3012 Model

4 4 Digital display reads “Hypro” upon initial power- up System then enters flow mode in standby –Operates as flowmeter Digital Display Operation

5 5 Push red “FOAM” button to arm system –“ON” light illuminates Open foam discharge –Displays solution volume –“ON” light blinks when foam pump runs Digital Display Operation

6 6 Water flow display Push “SELECT” button and total volume of water discharged is displayed –Gallons, liters, imperial gallons Digital Display Operation

7 7 Push “SELECT” button to enter “%” mode –Displays default injection percentage –“PA” Single tank system –“PC” Remote start/stop (“UP” or “DOWN” button will override default setting) Digital Display Operation

8 8 Push “SELECT” button to enter “TOTAL FOAM” –Displays total concentrate injected Dual-tank mode –Totals for each tank –Display corresponds to tank chosen by dual-tank valve

9 9 Digital Display Operation Enter “INJECTION PERCENTAGE” from any mode –Press either “UP” or “DOWN” button momentarily to display current percentage setting –Hold either button for two seconds to change setting accordingly

10 10 Operating Instructions System Reset Total Water %(Percent) Total Foam Reset these modes to 0 or % to default setting Push both the up and down buttons in desired mode

11 11 Size Max Accuracy Max Operating Tee Flow Range Flow Range 1-1/2x1" 5 - 110 gpm 3 - 145 gpm 1-1/2" 10 - 320 gpm 3 - 380 gpm 2" 15 - 520 gpm 5 - 625 gpm 2-1/2" 20 - 750 gpm 8 - 900 gpm 3" 30 -1150 gpm 12-1380 gpm 4" 55 -1980 gpm 20 -2380 gpm Flowmeter No flow restrictions Wide operating range

12 Safety Features

13 13 When Lo con is Displayed –Selected foam concentrate tank is getting low –If foam concentrate is added within 2 minutes Lo con goes out –If no foam concentrate is added within 2 minutes no con is displayed When no con is Displayed –Foam concentrate pump will not run –Add foam concentrate until no con display goes out then push Red Foam button to start the foam pump Low Foam Display

14 14 Exceeding Foam Injection Rate Hi Flo display –Occurs when the water flow and selected foam concentrate injection percentage exceeds the foam pump capabilities –Informs pump operator when this situation occurs –Lower the foam concentrate injection percentage or water flow to stop the flashing Hi Flo display

15 15 Motor Driver Module controls pump motor Totally enclosed environmentally sealed Incorporates system circuit breaker

16 16 Digital Display Operation Simulated flow –While in “FLOW” mode, push both lower buttons simultaneously –Three bars on left indicate manual mode –Pushing red “FOAM” button will turn foam pump on/off –Pump injects to simulated flow default setting

17 17 System Air Purge Enter “SIMULATED FLOW” Turn injection valve from “INJECT” to “CAL/FLUSH” Push red “FOAM” button on display to start foam pump

18 18 System Air Purge (cont.) Run until concentrate flows steady out of dump line Push red “FOAM” button to stop pump Turn injection valve to “INJECT” Exit “SIMULATED FLOW”

19 System Maintenance

20 20 2000 Series Foam Pump Totally enclosed environmentally sealed motor Housing incorporates speed sensor Positive displacement plunger pump –Components made of corrosion resistant materials –Max operating pressure is 400 psi

21 21 3012 Foam Pump Hydraulic motor Housing incorporates speed sensor Positive displacement plunger pump –Components made of corrosion resistant materials –Max operating pressure is 400 psi

22 22 System Maintenance Clean strainer(s) regularly –Purge pump to remove air pockets afterwards Check oil level –Dip stick reading or –Sight glass

23 Concentrate Management Systems

24 24 Foam Tank A Foam Tank B Manual CMS

25 25 Foam Tank B Electronic CMS Foam Tank A

26 26 Digital Display Operation Dual-tank function –Dual-tank valve in “A” –Displays “PA” and default setting –Dual-tank valve in “B” –Displays “Pb” and default setting Default settings from 0.1 to 6.0%

27 27 Dual Foam Concentrate Tank (CMS)

28 28 Dual-Tank Flush System does not require flushing after Class A foam use –Turn off and flush hose Flush after using Class B foam –Flow water and engage foam system –Turn manual valve to “FLUSH” or electric valve to “OFF” (“Off” position is a constant flush)

29 MultiFlo Interface

30 30 MultiFlo Interface Std. Controller or AFC MultiFlo Display Control Cable Flowmeter Cable Flowmeter