DAIKIN February 18 th, 2011 Daikin US How to Evaluate Refrigerants? >Global Warming Impact >Energy efficiency & Peak Load >Flammability & Toxicity >Affordability.

Slides:



Advertisements
Similar presentations
1 HCFC Phase –out in Air Conditioning Sector Background, Challenges and Progress Sidi Menad SI AHMED 17 TH October 2012.
Advertisements

R290 Air Conditioner Presented on behalf of GREE By Dr. Volkmar Hasse, GTZ-PROKLIMA INTERNATIONAL At the Joint West Asia and South Asia Network Meeting.
REFRIGERATION SYSTEMS
Risk Assessment of Mildly Flammable Refrigerants
Heating, Ventilating, and Air-Conditioning
Michael Galka and Dr. Paul Blowers The University of Arizona
CO 2 – the natural refrigerant for MT and LT in discounters, supermarkets and hypermarkets October 19, 2009 Bernd Heinbokel.
Heat Recovery for Commercial Buildings
HVAC System Design PES Institute of Technology. Objective Goal: To develop an automotive air-conditioning system that is smaller and lighter than with.
Session I Challenges and opportunities in addressing high-GWP HFCs in the refrigeration sector.
New Refrigerants Question Time Introductory Comments Ray Gluckman Director, Climate Change SKM Enviros April 26 th 2012, RAC, London.
Existing Replacements for CFC & HCFC Refrigerants and Future Low GWP Alternatives Dr. Frank Rinne Technical Programmes Manager DuPont Fluoroproducts.
R22 Phase Out Presentation To inform our customers of the single most important changes to the air conditioning industry in modern.
REFRIGERATION & AIR CONDITIONING DIVISION Hydrocarbons for Domestic Appliances Dr.-Ing. Jürgen Süss VP R&D Brussels, October 2009.
UNEP Workshop on HFCs management.
Session 3: Challenges and opportunities in addressing high-GWP HFCs in mobile air-conditioning Overview Pega Hrnjak Co-Director ACRC,
Overall issues for adequate design for high-ambient temperature operation by: Samir Hamed Petra Engineering Ind. Co. Rtoc member.
UNEP Workshop on HFC Management
Technical consideration of feasibility of low GWP alternatives: performance, cost, et.al. Kazuhiro Sato Mitsubishi Heavy Industries, Ltd. On behalf of.
Low-GWP options for cascade systems for medium-sized and larger commercial refrigeration equipment Workshop on HFC management Bangkok 20 th April 2015.
New Policy Measures in Japan that manage HFCs and promote alternatives. Masafumi OKI Ministry of Economy, Trade and Industry, Japan (METI) 12 July 2014,
P.K. Mahindra REFRIGERATION & AIR CONDITIONING MANUFACTURERS’ ASSOCIATION (RAMA) Oct 2011, New Delhi STAKEHOLDERS WORKSHOP ON HCFC PHASE-OUT MANAGEMENT.
Air Conditioning EPA Type II.
REFRIGERATION, COMPRESSED AIR SYSTEMS & EFFICIENT USE OF ENERGY
CHAPTER 6 Moving Heat: Heating and Air Conditioning Principles
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
Overview of EU Regulations affecting the use of Fluorinated Greenhouse Gases Tim G.A. Vink Director Regulatory Affairs, Compliance & QA Honeywell Fluorine.
Session 5 Overarching and cross-cutting issues on technical aspects of HFC management.
HFO Low Global Warming Technology Rene Mueller. Honeywell.com  2 Honeywell initiated R&D on low global warming programs in 2001 Programs in place for.
36th OEWG UNEP SIDE EVENT 22 J u l y , P a r i sRoberto Peixoto - IMT Roberto A. Peixoto Maua Institute of Technology – IMT Brazil Disclaimer: The.
Availability of Low-GWP Alternatives Options for Near Term & Longer Term Transitions OZONACTION NETWORK FOR LATIN AMERICA AND THE CARIBBEAN OCTOBER 6-8.
Energy efficiency in buildings Monga Mehlwana Tuesday, 05 October 2010.
Introduction of Low-GWP alternatives to HFC134a in Article 5 MAC Production: Cost & Safety Issue Prof. Jiangping Chen , Ph.D Shanghai Jiaotong University.
Modelling Long Term Hydrofluorocarbon Emissions Contribution to India's Global Warming Impact Mohit Sharma Junior Research Associate Council on Energy,
The new EU F-Gas Rules and their impact in Europe and globally By Andrea Voigt, EPEE Workshop on Hydrofluorocarbon Management Bangkok – 20 & 21 April 2015.
HFC Management by leakage reduction and recovery, and next actions for stepping forward. Tetsuji OKADA Japan Refrigeration and Air Conditioning Industry.
INDUSTRY PROGRESS AND NEEDS FOR REPLACING HIGH GWP HFC S Montreal Protocol HFC Management Workshop Paris July 11, 2014.
Budapest, 19th October 2015 Hilde Dhont Environment Research Center Daikin Europe Examples of Daikin’s contribution to the global energy & climate change.
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
Design What is the first step in designing a high-performance building? Would it be: Identify synergies Select the correct HVAC system Design around human.
Public Name: François Bruggemans Dept: New Business - Heating Carbon footprint of heating systems Lowering GHG emissions by the use of heat pumps.
Top secret Secret Internal use only Public R-32 The next generation refrigerant Name of Presenter.
00 Heat pumps by Kenneth Hoffmann. Why NH 3 Heat pump? NH 3 Heat Pump sizes Case stories CO 2 Heat Pump NH 3 Heat Pump applications NH 3 Heat Pump sizes.
Chillers for Tomorrow… Today. 50% Our Products 50% reduction in GHG via: 1) increased energy-efficient products; 2) use of next generation refrigerants.
BY SHASHANK. S. SURVE TEJAS. N. PAWAR. CONTENTS  INTRODUCTION:-  ABOUT HFO -1234yf.  STRUCTURAL FORMULA.  NEED OF HFO-1234yf.  WHY NOT R-134a SHOULD.
CASE STUDY : Solar Powered air conditioning as a solution to reduce environmental pollution in Tunisia.
Working group to: Address A2 and A3 refrigerants for IEC
HYDRONIC HVAC: The Most Comfortable and Efficient System
Introduction to Food Engineering
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Introduction to Air Conditioning and Climate Control
A New Approach to Emerging Technology
Commercial Refrigeration Trends and challenges for RECS
HYDRONIC HVAC: The Most Comfortable and Efficient System
. Level 3 Air Conditioning Inspections for Buildings
THIRD ANNUAL CO3OL WORKSHOP
FGas Regulation Revision : Industry Impact
Refrigeration Systems Regulation, Standards and Guidance
High Efficiency Room Air-conditioners
Hydrocarbon Refrigerants
Archana Walia Vienna July 9, 2018
Achieving the HFC Phase-Down in Europe
Refrigeration Systems Regulation, Standards and Guidance
New Zealand Testing and Compliance for Standards and Labelling
Radhey S. Agarwal Member, OORG
Creating Hot Water using Outside Air,
Introduction to Air Conditioning and Climate Control
ODS AND ALTERNATIVES IN RAC SECTOR
Jitendra Bhambure Executive Vice President Blue Star
on RAC Servicing Sector - Leakage Control -
Presentation transcript:

DAIKIN February 18 th, 2011 Daikin US How to Evaluate Refrigerants? >Global Warming Impact >Energy efficiency & Peak Load >Flammability & Toxicity >Affordability - “Quick Gain”

November 13 th, 2010 Daikin Industries, Ltd. 2 LCCP comparison (3.5 kW Room A/C) based on cooling and heating How to Evaluate Refrigerants? – Global Warming Impact - (3) Emissions during refrigerant production(2) Direct emissions(1) Indirect emissions Total Emissions = ( Precondition for Calculation ) - Recovery rate = 30%, Leakage rate= 5%/yr, Source of Emissions during refrigerant production is JRAIA 2004 Kobe Symposium GWP=IPCC 4th (the EU F gas regulation, the GWP of the IPCC1 apply where R410A is 1975) *1 Taking low pressure loss into consideration, narrower heat exchanger was used to reduce charge volume. *2 To improve efficiency, HX size was increased : Indoor HX x 1,1 + Path x 2, Outdoor HX x 1.2, and connecting pipe increased from 3/8=> 5/8 *3 To meet IEC requirements, charge volume was reduced: Indoor HX x 0.8, Outdoor HX x 0.5, narrower piping was used. *4 To Improve efficiency: Outdoor unit HX was increased x kW Room A/C in Europe – EuP Average Condition (EU Average = 0.43Kg/kWh) (Kg = Charge volume) R410A (1.2kg) R744 (0.84Kg) (*4) R290 (0.37kg) (*3) R32 (0.84kg) (*1) HFO1234yf (1.32 kg) (*2) R22 (1.14kg) (Kg ・ CO2) (Kg ・ CO2) (1) 14000(2) 1 (3) 0.5 (1) 15000(2) 1 (3) 0 (1) 12000(3) 390(2) 1800 (1) 12000(2) 2100(3) 23 (1) (2) 4(3) 23 (1) 12000(3) 12(2) 480 Disregarding IEC, the charge volume is 0.58Kg, and Indirect impact could be reduced by 16%

November 13 th, 2010 Daikin Industries, Ltd. 3 How to Evaluate Refrigerants? – Global Warming Impact - GWPCharge ratio %Modified GWP The direct global warming effect of R32 is only 26% of R22, and 24% of R410 Could be much lower by using micro channel heat exchanger GWP values are based on IPCC 4th report. (Note : for the EU F gas regulation, the GWP values of the IPCC1 apply where R410A is 1975) 75% reduction

November 13 th, 2010 Daikin Industries, Ltd. 4 How to Evaluate Refrigerants? – Energy-efficiencies - R410A (1.2kg) CO2 (0.84Kg) *4 Propane (0.37kg) *3 R32 (0.84kg) *1 HFO1234yf (1.32 kg) *2 SEER Comparison (cooling mode) HPs ( Reversible ) - 3.5kW-Room AC in Europe Consideration: A big difference exists in the peak power under cooling condition. HFO and CO2 will cause peak power problems in large cities. Power ratio Efficiency ratio Consideration: In terms of SEER, CO2 is the worst, and the rest of candidates are equivalent to R410A. R22 (1.14kg) If disregard IEC, the charge volume is 0.58kg, and SEER could be same as R22 (Precondition for Calculation) Note: HX= Heat Exchanger *1 Taking low pressure loss into consideration, used narrower heat exchanger to reduce charge volume. *2 To improve efficiency, changed sizes: Indoor HX x 1,1 + Path x 2, Outdoor HX x 1.2, and connecting pipe => 5/8 *3 To meet IEC requirements, charge volume was reduced: Indoor HX x 0.8, Outdoor HX x 0.5, and used narrower piping. *4 To Improve efficiency: Outdoor unit HX x 1.1 Peak power comparison (R410A ratio) under cooling condition Outside 35°C, room 27°CDB/19° CWB

November 13 th, 2010 Daikin Industries, Ltd. 5 Consideration on the use of 2L refrigerants classified by ASHRAE 34 and ISO 817 Class 1 (No flame propagation) (No flame propagation) Class 2L (Lower flammable with low burning velocity) Class 2 (Lower flammable with high burning velocity) (Lower flammable with high burning velocity) Class 3 (Higher flammability) (Higher flammability) CO2(R744 ) R410A R22 HFO 1234yf R32 Ammonia (Toxic) R152aPropane (R290) 1. Flammability of Class 2L is similar to ammonia. Consideration is ongoing to clarify the safety requirements to use 2L refrigerants 2. Commercial refrigeration and MAC (wrong use) which employed R290 caused fire accidents in the field 3. ASHRAE 34 recently reclassified R32 & HFO 1234yf down to new Class 2L (Lower flammability, low burning velocity) Beer cooler incident in Australia 10/19/95, CA: charging while engine was still hot 8/18/96, MS: low pressure hose from evaporator blew off 9/27/96, AR: torch used on truck AC unit after venting refrigerant Source: US-EPA in Bogota 2008 Fire accident s in case of HC use for cooking & heaters : ave.68/yr, death: ave.1.3/yr (01-06),:Source METI Japan Propane explosion in a New Zealand supermarket. Source: EFCTC newsletter ASHRAE 34: Class 1 = Non flammable, Class 2L Mildly flammable Class 2= Flammable, Class 3 = Highly Flammable How to Evaluate Refrigerants – Safety: Flammability -

November 13 th, 2010 Daikin Industries, Ltd. 6 While risk of R290 (propane) can be addressed with several measures (eg forced fan operation to lower concentration below LFL), repair and disposal risks remain considerably high TransportInstallationUseRepairDisposal Estimated Incidents/year in Japan with R290 room air conditioners, after Measures Optimistic Pessimistic Source : Risk assessment work on HC refrigerant carried out by JRAIA Non Fluorocarbon Refrigerant WG in Reason : -Human errors during repair & disposal, which is beyond the control of manufacturers - During repair & disposal there is no power supply for the unit, so measures such as forced fan operation do not work.

November 13 th, 2010 Daikin Industries, Ltd. 7 How to Evaluate Refrigerants – Cost up Factors - Important (ex.230g) Special joint Sealing etc. Necessary Necessary Unnecessary Unnecessary Unnecessary Unnecessary Necessary Special joint Unnecessary Necessary Special joint Unnecessary. Unnecessary Cost for safety Charge reduction Joint Electronic parts Leak detector Ventilation Modified facility Qualification Qualified person Two-stage comp. High-pressure etc. Cheap CO2(R744) Larger comp. Larger pipe etc. Near as R410A Same as R410A Modification required Same as R22 Cost for performance Compressor, EX, etc. Modified facility Modification Expensive HFO1234yf Cheap Refrigerant price Modified facility Modification Special facility Qualification Qualified person Qualification Cost for handling Manufacture Supply chain Installation Service Disposal R32Propane (R290) The Example of Room A/C Component which increases cost Consideration: CO2 requires significant cost for performance improvement. Consideration: Propane requires additional cost when taking safety measures in application and handling. Required in Japan

November 13 th, 2010 Daikin Industries, Ltd. 8 Difference in Situations HCFC to non- ODS HVAC Market Expectation HFC Emissions in 2050 (BAU) *1 Containment Measures Developing nations Not startedRapid76%Not in place Developed nations CompletedSaturated24% Partially in place (EU, Japan) *1: The figures are by Öko Recherche Early Implementation in Developing Nations is Most Important Change over to lower environmental impact refrigerants ASAP. Establish containment measures for further mitigating the impact. Early Implementation in Developing Nations is Most Important Change over to lower environmental impact refrigerants ASAP. Establish containment measures for further mitigating the impact. “Quick Gain” To significantly reduce future global warming impact “Quick Gain” To significantly reduce future global warming impact “NOW” Use Technology Available “NOW” How to Evaluate Refrigerants – Early Implementation -

November 13 th, 2010 Daikin Industries, Ltd. 9 Refrigerant application map for ACs and HPs (Daikin’s assessment for the time being) ? ? CO2 R32 CO2 、 NH3 R32 HFO Room split Commercial split Water heater Refrigeration Mobile Chiller HFO Daikin does not produce Today’s Focus

DAIKIN February 18 th, 2011 Daikin US Conclusion

November 13 th, 2010 Daikin Industries, Ltd. 11 Conclusion 2. A2L Class refrigerants for all capacity ranges can be used with only minor modifications To address climate change issues, quick actions are required. We are confident that R32 technology is one of the solutions that can quickly reduce greenhouse gas emissions from refrigerants, in both developed and developing countries. 1. Evaluate not only GWP but also the total GHG emissions (LCCP) 4. Earn “Quick Gain” for lowering future global warming impact. 3. Peak load should be considered when choosing candidates. In case of R32, higher efficiency and less refrigerant charge will lead to lower greenhouse gas emissions. Additional leakage prevention measures will contribute to emission reduction further, as is the case of all refrigerants. Not only seasonal energy efficiency but also efficiency in extreme temperature conditions (peak load) should be taken into consideration. It is important for the power supply infrastructure.

DAIKIN February 18 th, 2011 Daikin US Thank you for your kind attention