“INSULATOR IN OVER HEAD LINE”

Slides:



Advertisements
Similar presentations
High Voltage Braced Insulator Assemblies Design & Application
Advertisements

Unit 10 - Electricity.
OVERHEAD LINE INSULATORS
Electricity in the Home
Electrical Installation
DESIGN OVERHEAD TRANSMISSION LINES Prepared by:- Er. Varinder Kaur
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
Lightning and Power Transmission Lines EE --- Term Paper By ---
CHAPTER 9 Electrical Design of Overhead Lines
Electrical Power Systems
How Electricity enters in our houses Electricity supplied to us at our home is 220 volt and A.C.. This main line power and the wires carrying it are called.
TRANSMISSION LINES CHAPTER 2. TRANSMISSION LINES FUNCTION - to transfer bulk of electrical energy from generating power plants to electrical substations.
Underground Cables Chapter 11 V K MEHTA.
P  German physicist Georg Ohm ( ) found relationship between potential difference & current.  He kept potential difference & current.
Pole Mounted Switch Disconnector NPS
SOL 4.3 Electricity and Magnetism. a measure of the extra positive or negative that an object has + - charge.
1. ALTERNATING CURRENT- THE CURRENT SWITCHES DIRECTION BACK AND FORTH. Used in generators, motors, and power distribution centers 2.Direct current- electricity.
A SAMMINAR ON ELECTRICL TRANSMISSION LINE
Intro to Electricity. What IS Electricity? A form of energy resulting from the existence of charged particles.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
The 13 Amp PLUG Fuse Insulating Casing Live Wire Neutral Cable grip Flexible Copper conductors Earth.
Practical electricity 2: uses and safety. a battery… a current can only flow when a circuit is complete… 12V 0 V.
Submitted to: Submitted by:
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
UNDERGROUND CABLE.
ON 400 KV GSS RAISER JAIPUR ROAD ,BIKANER
132KV GSS PIPAR CITY JODHPUR
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Submitted To:- Submitted By:- Mr.
A PRESENTATION On 400KV GSS SURPURA JODHPUR
1 Transmission of Electrical Energy Electrical energy is carries by conductors such as overhead transmission lines and underground cables. The conductors.
Electrical Circuits Chapter 20 Section Three. Science Journal Entry #42 Expound upon Ohm’s Law and its relationship to current, resistance, and voltage.
Electricity Day 2. Conductors A conductor allows charges to flow easily Some conductors are better than others Examples: Copper Iron.
OTDS Ltd. Overhead Transmission Distribution Systems OTDS OIL FILLED TRANSFORMERS | POWER TRANSFORMERS.
Electrical Power System SMJE 2103
LIGHTENING PROTECTION USING LFA-M
TRANSMISSION AND DISTRIBUTION
Electricity. TYPES OF CIRCUITS Individual electrical circuits normally combine one or more resistance or load devices. The design of the automotive electrical.
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
Electrical Power System SMJE 2103 Electrical Power Delivery System.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
GUIDED BY: DR. NILESH CHOTHANI PREPARED BY: SEJAL SHAH( )
P.1 Book 4 Section 3.2 Mains electricity and household wiring Electricity: friend or foe? Alternating current and mains circuit Safety designs in domestic.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
High Voltage Engineering
Sub Station.
Electricity and Magnetism
A SEMINAR ON LIGHTNING ARRESTER
High Voltage Engineering
Intro to Electricity.
AHMEDABAD INSTITUTE OF TECHNOLOGY
Topic Name: INSULATORS
Electricity is produced at the power station.
MAGM 262 Hydraulic Seals Mr. Conrado.
Ms. Tahoora Qureshi, Asst. Professor
Basics of electrical engineering
Introduction To Reactive Power
Circuit Breakers & Reclosers
Materials and their Properties.
Electric Circuits Chapter 22 Section 3.
BEF Electric Power Transmission and Distribution
Natural Sciences and Technology Grade 6
We have been working on Investigating Circuits. Let’s Review…
Daffodil International University
“Insulators.
A.C. DISTRIBUTOR CALCULATIONS
Chapter 11 Principle of power system by V K Mehta
Instruments & Electrical Measurements Lecture 4
Under Ground Cables By Dr. P. Bala Chennaiah, Associate Professor,
Level 2 Electrical and Electronic 3
Presentation transcript:

“INSULATOR IN OVER HEAD LINE” VIGNAN INSTITUTE OF TECHNOLOGY AND MANAGEMENT A SEMINAR ON “INSULATOR IN OVER HEAD LINE” PRESENTED BY GUIDED BY L.SUSHREE SRABANI DAS PROF.AMAR KUMAR BARIK 1221301014

CONTENT 1.INTRODUCTION 2.TYPES OF INSULATOR 3.INSULATING MATERIAL 4.INSULATION FAILURE 5.TESTING OF INSULATOR 6.USES 7. CONCLUSION 8.REFERENCE

INTRODUCTION

INSULATOR INTRODUCTION- Transmission line insulators are device use to contain,separate Or support electrical conductors on high voltage electricity supply Networks. The Insulators provide necessary insulation between line conductor and supports and thus Prevents any leakage current from conductors to earth. Insulator play an important role in over head line.

PIN TYPE INSULATOR Pin type insulator is secured to the cross arm on the pole. There is a groove on the upper end of the insulator for housing the conductor. Pin type insulator used in transmission & distribution of electric power voltage up to 33kv.

ADVANTAGES OF SUSPENSION TYPE INSLATOR 1.Each suspension disc is designed for normal voltage rating 11KV(Higher voltage rating 15KV), so by using different numbers of discs, a suspension string can be made suitable for any voltage level. 2.If any one of the disc insulators in a suspension string is damaged, it can be replaced much easily. 3. Mechanical stresses on the suspension insulator is less since the line hanged on a flexible suspension string. 4.It is cheaper than pin type insulator.

SHACKLE TYPE INSULATOR The shackle insulator or spool insulator is usually used in low voltage distribution network. It can be used both in horizontal and vertical position. The use of such insulator has decreased recently after increasing the using of underground cable for distribution purpose.

INSULATING MATERIALS There are several types of materials are used in over head line i.e glass,wood,mica,porcelain,rubber,fibre etc. But in over head line most commonly porcelain is used.

porcelain

INSULATING FAILURE There are different causes due to which failure of insulation in electrical power system may occur. Let's have a look on them one by one- 1) Cracking of Insulator The porcelain insulator mainly consists of three different materials. The main porcelain body, steel fitting arrangement and cement to fix the steel part with porcelain. 2) Defective Insulation Material If the insulation material used for insulator is defective anywhere, the insulator may have a high chance of being puncher from that place. 3) Porosity in The Insulation Materials Due to porosity , insulator absorb water from atmosphere and electrical resistance of insulator decreases.

4)Flash Over Across Insulator- If flash over occurs, the insulator may be over heated which may ultimately results into shuttering of it. 5)Mechanical Stresses on Insulator- If an insulator has any weak portion due to manufacturing defect, it may break from that weak portion when mechanical stress is applied on it by its conductor.

TESTING OF INSULATOR 1.MECHANICAL TESTING: 2.POROSITY TESTING: To ensure the desired performance of an electrical insulator, that is for avoiding unwanted insulator failure, each insulator has to undergo numbers of insulator test. 1.MECHANICAL TESTING: If an insulator has any weak portion due to manufacturing defect, it may break from that weak portion when mechanical stress is applied on it by its conductor. 2.POROSITY TESTING: In this test insulator broken into pieces and immersed in some kind of dye solution with high 3.FLASHOVER TESTING: This test is performed to get the flashover voltage of certain insulator.

4.PUNCTURE TESTING: Flashover testing is 3 types- Dry flashover test. Wet flashover test. Impulse flashover test. 4.PUNCTURE TESTING: This test is performed to find puncture test of an insulator. In this test, the total insulator is immersed in oil and subjected to a gradually increased voltage.

USES OF INSULATOR Electrical Insulator must be used in electrical system to prevent unwanted flow of electric current to the earth from its supporting points. It is mainly used in over head line to hold the bare conductor which carries the voltage and current one end to another end without fail. The insulator plays a vital role in electrical system. Electrical Insulator is a very high resistive path through which practically no electric current can flow.

CONCLUSION- Insulator is a main part of an overhead line. So it is mainly used in over head line to hold the bare Conductor.

REFERENCE- V .k meheta , power system, 3nd ed., S. Chand publication. Sue Taylor (May 2003). Bullers of Milton. ISBN 978-1-897949-96-2. www.Insulating Material _ Porcelain Glass Polymer Insulator _ Electrical4u.htm Www. Electrical Insulator Testing _ Cause of Insulator failure _ Electrical4u.htm

ANY QUESTION…