We turn the AIR into a TOOL MOTOR BLOWER BASEPLATE Commonly used Nantong motor Imported from France Made in Taicang factory
Company & Products Introduction
Manufacturer of Centrifugal Multi-stage Blowers & Exhausters Founded in 1973 Continuous R&D and production improvement Several thousands of machines successfully installed The symbol of reliability and confidence for continuous duty Number one European Manufacturer ISO 9001:2000
United States Germany Italy Venezuela United Arab Emirates Great Britain Spain France (Head Office) China Chile South Africa Australia
The Factory A factory of more than m² in the Ain Department China Factory in Taicang with 1630 m²
Dynamic balancing ISO 1940 / 1 : G 2.5 Test before supplying
Processing Turning machine with digital command
The norms we respect Vibrations classe ISO Dynamic balancing class ISO 1940/1 – G2.5 ATEX Zone I & II Category 2 G /3 G Construction can be done according to API 617 Aerolic performances according to ASME PTC 10
The manufacturing standards we respect 98/37/CE (machines security) 89/336/CEE (electromagnetic compatibility) And we are in conformity with these following standards: EN 292 (Machines security) EN (Machines’ electric equipment) EN (electromagnetic compatibility) EN (electromagnetic compatibility. Immunity)
Inlet filter Discharge flow Bearing housing Baseplate Bareshaft Direct coupling Metallic expansion joint Inlet Flow
BLOWER MOTOR BASEPLATE
Fabricated and cast impellers Highest specification in casting in the trade All major components are manufactured in our factory for better quality assurance Baseplate are earthquake certificated for a longer life Sand blasting and special Coating Casting Riveting Casting Riveting
Graphit ring Labyrinth sealing Bearing Oil diffuser & Cooling auto fan Oil slinger Cooling auto fan End of shaft at the blower inlet
Carbon rings Bearing Bearing clearance Labyrinth seal Oil slinger End of shaft at the blower outlet for Special gas Oil diffuser & Cooling auto fan Carbon seal ring
Only two parts in contact between the rotor and the stator Bearing mounted outside for a total oil free air and an easy replacement Maintenance is composed of the following: Oil filling Bearing change every 5 years Filter panel cleaning Maintenance
Blowers Performances
Exhausters Performances
Various application fields Waste Water Treatment : aeration Centralized Vacuum Cleaning Carbon Dioxide Compression Biogas Recovery Drying Systems Flotation Sulfur Recovery Unit Fluidizing And many others…
China Waste Water Treatment Plant of typical cases Jinan water purification No.3 factory Ningbo Beilun Xiaogang WWTP
China Waste Water Treatment Plant of typical cases Foshan Chengbei WWTP Foshan Gaoming WWTP
SELECTION AND REGULATION
Information needed for a selection Elevation: bar or kPa or masl (meter above sea level) Flow : Nm 3 /h, Normal m 3 /h (0°C, 1.013bar) Sm 3 /h, Standard m 3 /h (20°C, 1.013bar) kg/h Im 3 /h, Inlet m 3 /h Discharge pressure : in mH 2 O or kPa or bar… Relative humidity: % Maximum inlet temperature: °C Minimum Inlet Temperature: °C
For example selection software parameters Winselect
For example selection software parameters Calculator
Standard Curves DESIGN PRESSURE SYSTEM RESISTAANCE CURVE STATIC HEAD
REGULATION Outlet valve Inlet valve
50% 100% 75% 25% Outlet Throttling
Inlet Throttling 100% 80% 60% 40% 20%
Variable frequency speed 2980 rpm2800 rpm 2620 rpm 2430 rpm
Regulation and control
Control Panel Specification Continuous check of: Inlet and outlet bearings temperature & vibration Overload Inlet & outlet valve, VFD and By-pass valve control Filter clogging indicator Regulation (D.O control, flow control, constant pressure, and many other customize regulation) Anti-surge protection Offline Website - PC\Continental Industrie.exeOffline Website - PC\Continental Industrie.exe