FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.

Slides:



Advertisements
Similar presentations
Common Components of a Traditional Wood Framed Building
Advertisements

Loft Conversions - The building regulations Chris Wigley MD London Building Control Ltd
Classroom Safety. Fire & Life Requirements as per State Education Dept The following list relates to the classrooms and adjacent areas. They are provided.
7 | Means of Egress (Life Safety Code)
Determining the Occupant Load
Fire-Resistive Construction (2nd part)
Installation of Mechanical and Electrical Services
Summary of NFPA 101 Interior Finish Requirements
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Frontline Fire Officer Training: Firestopping and Path of Travel Why it should matter to you Developed by the International Firestop Council
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
of NFPA 101 Life Safety Code Administration Definitions General
ACCESSIBILITY: A CODE COMPLIANCE AND EXISTING CONDITIONS ASSESSMENT AND SURVEY OF THE LIMERICK TOWN HALL MAIN STREET LIMERICK, ME ttl-Architects LLC 28.
IRC 2009 Habitable Attics.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
2007-CBC - UL Damper Requirements
NFPA Chapter 6 Chapter 6 is used to classify the occupancy and the hazard contents Proper classification is used to guide the implementation of.
Chapter 23 Interior Walls & Partitions. Interior Partitions Performance Criteria  Strength  Fire Resistance  Durability  Acoustical Isolation Materials.
This presentation is designed to assist trainers conducting OSHA 10-hour General Industry outreach training for workers. Since workers are the target.
Fire Suppression Techniques IFSTA Chapter 14
Smoke Control Fire-Rated Stairwells Fireproofing of Structural Components Egress Lighting Fire-Resistive Construction Elements Fire and Smoke Dampers Emergency.
Won’t count Won’t count Another quiz, in two weeks Another quiz, in two weeks The Quiz.
 Safety at Home  Millions of people each year are seriously injured in their own homes  Most can be prevented.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Architectural CAD I – IM230
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
EGRESS AND FIRE PROTECTION
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
HVACR116 – Trade Skills Mechanical Drawings.
Building Codes and Interior Design
NO EXIT (adapted from OSHA Office of Training and Education)
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Means of Egress Chapter 4.
{ CASE STUDY TO EVALUATE THE EFFECTS OF BUILDING CODE VIOLATIONS ON A FATALITY FIRE Noel Putaansuu, CFI Michael M. Fitz, P.E., C.F.E.I., C.F.P.S. MDE,
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Common Components of a Traditional Wood Framed Building
Fire Safety By Alicia Civile and Alexandra Fernandez.
Hunter McWhorter Mark Menard Steven Hammock. Inspectors never fail to check the required emergency-egress window from a sleeping room. At least one window.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Overview Identify the unique construction factors of single-family dwellings. Recognize the.
MODULE 6: PRIVATE DWELLING SIMULATIONS. OBJECTIVES Module 6 Identify the unique construction factors of single-family dwellings. Recognize the basic problems.
CLIC CES Meeting 14 jan 2009 A resume table for fire safety in LHC, and a possible scheme for other machine – part 1 CERN –SC Fabio Corsanego.
Lift Typical Building Floor Plan. Complete with fire walls. Click on and we will add Some of the different Passive and Active systems that you could come.
The Essentials of Egress
INTD 51 human environments building code. building codes deal with almost every area of building planning, design & construction they are very complex.
Picking up from last week…. Fire stair layout Fire stair layout Due October 18 th Due October 18 th Assignment #1.
Fire No institution is immune from fire. Flood damage can be dried out and restored, stolen property has a chance of being recovered; damage from fire.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
Design Development Code analysis Partition types.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
Fire-Resistant Materials & Assemblies Part 2 Chapter 5.
Means of Egress Part 3 Chapter 4.
ID 234 Building Codes Fall 2012 Vertical Components of Egress.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Chapter 4 ID 234 Building Codes Fall 2011 Means of Egress.
Fire Safety By Alicia Civile and Alexandra Fernandez ASSIGNMENT 4.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
3M B&CSD - Fire Protection Space for 3M Montage © 3M All Rights Reserved. 3M Fire Barrier Duct Wrap 615 For Ventilation Ducts.
APPLICATIONS OF TECHNOLOGY
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
Flammable Liquids Directorate of Training and Education
Building Construction Related to the Fire Service Chapter 1 — Building Construction and the Fire Service.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Final team building Presentation
FIRE SAFETY AND PREVENTION
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Fire Door Inspections Qualified Training
Common Components of a Traditional Wood Framed Building
Building standards Mr. Da Silva.
Presentation transcript:

FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS

COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical wiring careless use of matches and cigarettes

FIRE SAFETY CODES PRESCRIPTIVE PERFORMANCE BASED

Design for Fire Safety.A fire can spread at the rate of 4.6 meters (15 ft) per second The best design for fire safety is also good design for lighting, thermal,acoustic, and water systems. thermally massive materials High ceilings

CONFLICTS. High ceilings and low partitions. Fire builds up faster in small, enclosed rooms that retain heat Buildings without operable windows or with sunscreens covering windows block access by firefighters and escape by occupants

Protecting the Structure

AREAS OF REFUGE Areas of refuge are commonly located adjacent to a protected stairway, and are protected from smoke. They are provided with communications devices to summon firefighters to rescue the people in the refuge. When a stairway is used as a refuge area, it is designed to hold all the building occupants, allowing 0.28 square meters (3 square ft) per person.

HORIZONTAL EXITS A horizontal exit does not lead to the exterior of the building. Instead, it provides a protected exit to a safe area of refuge in another part of the building or an ad- joining building without a change in level. The horizontal exit uses fire-rated walls and doors to subdivide a building into separate areas, which are then treated as separate buildings. Occupants escape from a fire on one side by moving horizontally through self-closing fire doors to the other side.

VERTICAL OPENINGS shafts of any kind, including stairs, elevators, ductwork, and electrical wiring and piping chases, must be enclosed with fire-rated walls with self-closing fire-rated doors at each floor.

Construction assemblies have been assigned one-, two-, three-, and four-hour ratings by ASTM E Assemblies that are tested this way include permanent partitions, shaft enclosures for stairways and elevators, floor/ceiling constructions, doors, and glass openings. Doors and other opening assemblies also receive 20-, 30-, and 45-minute ratings.

DOORS Fire doors are actually entire door assemblies. The typical fire door includes the door itself, the frame, the hardware, and the doorway (wall opening).

STAIRS Most stairs must have a clear minimum width of 112 cm (44 in.). With an occupant load under 50, a 914-cm (36-in.) minimum width is permitted.

FIRE DAMPERS DRAFT STOPS

SMOKE MANAGEMENT smoke may move more than 25 cm per second (50 ft per minute) from the point of origin to kill people who are unaware of the fire. Once the flame is visible, smoke may move more than 50 cm per second (100 ft per minute) before the flame starts to spread.

Smoke Barriers Smoke Confinement Smoke Dilution

Escape Routes MEANS OF EGRESS Any means of egress has three components: the exit access, the exit, and the exit discharge.