DGFLOW srl www.dgflow.it Italy Via Emilia, 5 - Loc. Stradella 46030 Bigarello - Mantova - Italy www.dgflow.it.

Slides:



Advertisements
Similar presentations
Engineer Training XL1200 Pneumatics. Engineer Training XL1200 Pneumatics Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:
Advertisements

BeginningNext SlideBack End Program AVADAL 1 of 21 SK-1 Roller Apron Segment Overview.
Star kW NEW. Star kW Star kW Instantaneous wall-hung gas boilers Conventional flue Sealed room fan assisted NIKE Star 23 kW EOLO Star 23 kW.
Customer Service – International dept. STAR 24 3 E.
MCS LWC MAGNUM ORIGINAL CONCEPTS  Designed to Control Loop Systems  Build to be generic and handle many configurations of Loop Controllers  Type of.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Marine Safety Requirements IPS 1050 and ”IPS 900MC”
Daikin Altherma™ Troubling Shooting
HEAT PUMPS.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
Welcome to Malaga WeBex Common Rail Fuel System
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
Unit 206: Domestic hot water systems
Customer Service VICTRIX 90 Central heating only, wall hung condensing boiler.
DIVATOP 60 New Wall Hung Gas Fired Boiler. Divatop 60: Main Features Leader in wall hung boilers Ferroli Ferroli, in line with its position as a comfort.
AccuMax Single Point Injection Operation (See Installation and Operation Manual for detailed instructions)
1 Engine Protector Safe Rider Vehicle Technologies (Pty) Ltd PO Box 11376, Rynfield South Africa Tel./ fax Cell:
MILK PASTEURIZER. One milk pasteuriser with a capacity of litres of milk for hours, HTST type with an operate range from 75° to 95°C, including.
JET PROPULSION Part 6 Jet Engine Operation Fuel Systems.
Pneumatic Logic Sensors and Actuators
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
Product Introduction.
AccuMax Multi-Point Injection Mechanics
Hydronic Mechanical Controls
Domina PLUS B WORKING DIAGRAMS TROUBLESHOOTING INTERNAL VIEWS WIRING DIAGRAMS INSTALLATION 03 PREVIOUS MODEL.
MDS Smart Commander.
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
Settings & Adjustments. Settings & Adjustments.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Engineer Training Cooler TJ8300 / TJ8500 Cooler. Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction.
Hydraulic Kit (pump and tank) Pictures from prototype.
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
Applied Systems News FWEC*A Rudolf BARET HEISSIG.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
FC Flow Control: Centrifugal pump with constant speed (rpm) Orifice plate sensor Globe valve FC Flow Control: Positive displacement pump Orifice plate.
Fan Coils Units Control
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Invensys Controls Europe An Invensys Company EWCM 41x0 family New 32x74.
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Service Section Technical Training December 2005.
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
Building 180 NORMATEF TEST FACILITY Demineralized cooling water station upgrade R. Bozzi / EN-CV.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Documento riservato – A solo uso interno / Confidential document – Internal use only LUNA DUO-TEC MP.
James McIntyre VRF Training Manager V5 Key Components.
2016 Customers Meeting. PRODUCTS OVERVIEW Pressure switches for water pumps Electronic controllers for water pumps Variable frequency drivers for water.
Fixed Orifice Tube Cycling Clutch System (FOTCC)
Fan Coil Controller FC/S 1.1
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
PV100&PV200 Solar Pumping VFD
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
MEDIUM VOLTAGE APPLICATIONS.
Basic principles of hydraulic symbols
HIGH PERFORMANCE PRESSURE SYSTEMS.
Welcome to Malaga WeBex سیستم سوخت رسانی ریل مشترک کاتر پیلار
Frese DPRV Introduction Introduction 2017.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Hot water Systems Heaters.
Customer Presentation
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
NEW ARISTON STORAGE BOILERS March, 2009.
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
Presenter's Name TENSIONING SYSTEM DEMO UNIT.
Presentation transcript:

DGFLOW srl www.dgflow.it Italy Via Emilia, 5 - Loc. Stradella 46030 Bigarello - Mantova - Italy www.dgflow.it

Products: 1. ON-OFF systems a. PRESFLO b. PRESFLO multi basic c. PRESFLO multi d. PRESET e. PRESFLO multi cos phi 2. Variable speed drive a. STEADYPRESS All electronic boards have been immerged in a resin to prevent condensation

PRESFLO Advantages : Start/stop buttom on the cover With or without pressure gauge Different types in function of pump power Start up pressure : 0,8 – 1,5 – 2,2 bar Dry running protection protection against excessive frequent starting Max power : up to 2 Hp (1,5kW) 16 Amp. IP 65 Max operating pressure : 10 bar NO need to use an additional expansion vessel Installation : any kind Real non return valve incorporated Continous duty with flow higher than 2l/min

PRESFLO multi basic Advantages : Start /stop buttom on the cover Without pressure gauge With expansion vessel 3 liter With digital pressure sensor Selectable start up pressure with jumper from : 1 - 2 - 3 - 4 bar Dry running protection protection against excessive frequent starting Max power : up to 1 Hp (0,75kW) 8 Amp. IP 65 Max operating pressure : 10 bar NO need to use an additional expansion vessel Installation : any kind Real non return valve incorporated Continous duty with flow higher than 2l/min

PRESFLO multi Advantages : Start/stop buttom on the cover Digital display With expansion vessel 3 liter With digital pressure sensor Protection against over current (settable) Selectable start up pressure with push bottom in steps of 0,5 bar from : 1 till 5 bar Dry running protection Protection against excessive frequent starting Max power : up to 1,5 Hp (1kW) 16 Amp. IP 65 Max operating pressure : 10 bar NO need to use an additional expansion vessel Installation : any kind Real non return valve incorporated Continous duty with flow higher than 2l/min

PRESET Advantages : Start/stop buttom on the cover Digital display Electronic pressure sensor Dry running protection Protection against over current (settable) Starting pressure adjustable from 1 till 9 bar Cut out pressure adjustable from 1 till 9 bar Max power : 2 Hp (1,5kW) 16 Amp. IP 65 Max operating pressure : 10 bar Need to use an additional expansion vessel Installation : any kind Real non return valve incorporated Continous duty with flow higher than 2l/min

PRESFLO multi cosfi Advantages : Start/stop buttom on the cover Digital display With expansion vessel 3 liter With digital pressure sensor Protection against over current (settable) Selectable start up pressure with push bottom in steps of 0,5 bar from : 1 till 5 bar Double Dry running protection Protection against excessive frequent starting Max power : up to 1,5 Hp (1kW) 16 Amp. IP 65 Max operating pressure : 10 bar NO need to use an additional expansion vessel Installation : any kind Real non return valve incorporated Continous duty with flow higher than 2l/min

1. Pressure(p)= CONSTANT STEADYPRESS WHY ? 1. Pressure(p)= CONSTANT 2. Flow (Q) = VARIABLE 3. Speed (Rpm) = VARIABLE

STEADYPRESS Advantages : Start/stop buttom on the bottom Digital display With digital pressure sensor Protection against over current (settable) Selectable start up pressure with push bottom in steps of 0,5 bar from : 1 till 9 bar Dry running protection Protection against excessive frequent starting Max power : up to 3 Hp (2,2kW) IP 65 Max operating pressure : 10 bar Need to use an expansion vessel Installation : any kind Real non return valve incorporated Continous duty with flow higher than 2l/min

STEADYPRESS PRESSURE LOSSES :

STEADYPRESS TYPES :

STEADYPRESS COOLING PLATE Real NON-RETURN VALVE & FLOW SENSOR

STEADYPRESS Hydraulic caracteristics : Maximum working pressure : 10 Bar Maximum testing pressure: 40 bar Digital pressure sensor : 0 - 9 Bar Flow sensor Flow : up to 200 l/min Water temperature : up to 50 °C

Power supply variations : +10% STEADYPRESS PROTECTIONS : Power supply variations : +10% Dry running Fase dectection Overcurrent Lighting Anti Frost Unlock

STEADYPRESS Extra electronic board for connecting more inverters: especially for boostersets Connection for : Boosterset up to 3 pumps Float switch or minimum pressure switch or 2de setpoint Alarm

STEADYPRESS

STEADYPRESS View from the side View from the top

STEADYPRESS

STEADYPRESS

STEADYPRESS