Introducing GAC’s New Line of Intelligent Generator Set Controllers
The InteliGen Stand-By, Prime Mover (single and multiple set), and Parralel to Utility (single and multiple set) Applications Features: 128 x 64 LCD 9 / 9 Discrete Inputs and Outputs (Configurable) Expandable to 21 / 21 3 Analog Inputs (Fuel Level, Coolant Temp., Oil Press.) Expandable to 7 and 1 Analog Output Speed Measurement (Mag Pick-Up) 3 Phase Generator / Utility Voltage Measurement 3 Phase Generator Current Measurement 1 CT Input for Utility Measurement or Earth Fault Protection RS232 for Direct Communication Meets NFPA110 (w/ Annunciator Module iGL-RA15) Remote Communication (Analog, Internet, and GSM)
InteliGen Connections 3 Phase Utility Voltage 3 Phase Generator Voltage 9 Configurable Discrete Inputs and Current Connection for IOM / COM Module Connection for Power Modules Mag. Pick-up 3 Analog Inputs (Oil, Temp., Fuel.) Direct PC or Modem Connection Utility Current 2 Relay Outputs (Starter, Fuel Solenoid) 7 Config. Outputs 12 or 24 V DC
InteliGen’s Modules Sharing) AVR control (needs 18 V AC power supply) Power Control Modules: PCM and PCLSM (with Load Sharing) AVR control (needs 18 V AC power supply) Communications Expandable I / O Modem Support (multiple set applications)
Power Control Modules Shielded Analog Load Sharing Line (PCLSM only) Governor Control Output AVRi Output Mounts Directly to Back of InteliGen 4 Discrete Inputs 12 or 24 V DC 4 Discrete Outputs
Output Level Adjustment (turn pot) AVRi Module Output Level Adjustment (turn pot) 18 V AC Power Supply Output for AVR Control Input from PCLSM DIN Rail Mounting
Communication Module Used for Multiple Set Applications Communications Between Sets Mount: Back of InteliGen Up to 32 Sets Use one Modem (w/iG-MU) RS232 port for IOM
IOM / PTM Module 9 Discrete Inputs w/ Active LED 4 Analog Inputs* 1 Analog Output RS232 for Direct PC Connection RS232 Connection to InteliGen 9 Discrete Outputs w/ Active LED 12 or 24 V DC w/ Power LED DIN Rail Mounting
InteliMains: InteliGen With Special Software Mains (= Utility) Circuit Breaker Control Reverse Synchronization Vector surge protection (locally required) Power Management - Engine Usage Optimization Number of running engines: Dependent on required load Engine starting order: Dependent on running hours Import/Export Control
Parallel To Utility & Other Gen Set’s InteliMains G + iG-COM + iG-PCLSM iG-PCLSM iG-COM G + iG-COM + iG-PCLSM iG-PCLSM iG-COM
InteliGen’s User Friendly Operating Software Setpoints Controller Free User Friendly PC Format History Values
Value Screen Values in Real Time. Screen Selection Metering All Metered Values in Real Time. Metering Screen Selection
History Every Action Logged All Values Associated w/ that Action Up to 177 events (FIFO)
Controller Same as Keypad Essential Metering Alarm List
Setpoints Change any Setpoint Current Value Range Value Screen Selection Acceptable Range for Parameter
Customizable Software Parameters Nominal RPM 80 300 Multilingual Texts Overspeed Überdrehzahl Sobrevelocidad Units °C F; kPa bar psi Controller Operating Mode SPM SSB SPtM MINT MEXT Text Water temp Coolant temp
Modem connection to remote monitoring* SMS (Mobile phones) connection* Communications Local connection to the Control System Modem connection to remote monitoring* SMS (Mobile phones) connection* Internet connection*
Controller Screens Analog Meters Bar Graphs Numeric Values Controller Screens Allow for Similar Interface as WinEdit Software MAINS: 230 228 233V 50.0Hz GENERATOR: 1517RPM 221 223 220V 50.6Hz 872 896 932A 0.98L 183 194 208kW 118kVAr Running in Island Water Temp 91°C Oil Pressure 5.1bar Fuel level 75% Battery voltage 25.2V
Setpoint Adjustment Three Level Password Protection Adjustable via iG Keypad Three Level Password Protection PARAMETERS MF-Start Delay 3s Start Attempts 5 Mains OK-Delay 10s Cooling time 30s
History Screens as well as WinEdit Viewed on Multiple Screens History Events Can be Viewed From iG Screens as well as WinEdit Viewed on Multiple Screens -15 FINISHED HOUR 07:00:00 16.10. -16 GCB CLOSED-ISLAND 06:23:53 16.10. -17 ENGINE START 06:23:49 16.10. -18 MF-MCB OPENED 06:23:44 16.10. 85kW 1503RPM 0.81L 88C 6.1bar 24.9V 84% 50kW 1495RPM 0.72L 25C 5.3bar 24.7V 87% 0kW 0RPM - 22C 0.0bar 25.8V 87% 0kW ORPM - M 0 0 0V 0.0Hz G233 227 229V 50.1Hz G230 228 223V 49.8Hz G 0 0 0V 0.0Hz M190 195 201V 48.7Hz 121 125 124A 62kVAr 27 29 29kW 72 73 71A 48kVAr 17 18 16kW 0 0 0A 0 0 0kW
Protection Handling Adjustable Delay Settings Five Protective Actions Warning Slow stop Shut-down Unloading History Record Reset Function (Horn + Flashing Light)
Protections Voltage and Current Asymmetry OverCurrent OverLoad Generator / Utility Over / Under Voltage and Frequency Voltage and Current Asymmetry OverCurrent OverLoad Excitation Failure Earth Fault Oil Pressure (two level: warning, shutdown) Coolant Temp. (three level: low temp warning, high temp warning, and high temp shutdown) Fuel Level (two level: warning, shutdown) …
Summary The InteliGen Offers the Right Solution for the Application. Never Pay for Unneeded Features. GAC Leaves it up to You to Make the Intelligent Choice!!