Introducing GAC’s New Line of Intelligent Generator Set Controllers

Slides:



Advertisements
Similar presentations
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Welcome to the Radionet Monitoring Secure-Com Presentation.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
G-Eye Extending your monitoring & control capabilities
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
SV100 Open-Loop Vector VFD FV100 Closed-Loop Vector VFD 1.
Prestige 2.0 Commercial Thermostat with Internet Connectivity.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
TandD RTR-500 Series Family of Wireless Data Loggers Multiple Data Collection Options Suite of Software Tools.
“NEFTOGAZ TECH” LLC President of the Group of companies “ND” Leonid Pashkevych, 2014 Specialized presentation about the System of complex automation of.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
MODULAR SMPS POWER PLANT
Protections from the technical point of view “What you always wanted to know about protections and were afraid to ask…” Petra Píclová Online training
SYMAP-BC SYMAP-BC.
Remote Monitoring and Management Solutions ®
KLINGE’S NMR 262 Two Independent Systems Integrated into one Unit This Requires Special Features:  Total Redundancy of Refrigeration Components  Total.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Introducing GAC’s New Line of Intelligent Generator Set Controllers.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
1 PCA2 On-load Protection Condition Analyser. 2 PCA2 online testing concept Concept introduction: PCA2 is a new system test approach intended to save.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
MIG II DIGITAL FEEDER PROTECTION
G GE Power Management 369 Motor Management Relay.
1 Industrial Systems A dvanced L ine P rotection S ystem.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
Introduction Mobile Switch is a device which will be helpful to switch on and off any electrical/electronic devices through a SMS. The parameters of these.
G650 Generator Protection & Control System
1 © Red Lion Controls Inc. Introducing the RAM 9000.
Testing and Development Activities of Meter-Base Switches for DER Applications Power Systems 2005 Conference, Clemson University March Panel.
Looking for a more powerful circuit monitor?
REMOTE SITE MANAGEMENT SOLUTION. AGENDA 2  About KoçSistem  Current Situation in Base Stations  Remote Site Management System: Sitelink  Sitelink.
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
FG Wilson Access 4000 Control Panel
Operator Panel and Programmable Logic Controller.
1 9/10/2015 PanelDog DC Graphical LCD Meter Series.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Modular Inverter.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Hardware Training Product: ITMS2.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
SmartMQn Motor Horner APG, LLC September 9, 2008.
New Product Developments World Leaders in Combustion Management Solutions Mk.7 Data Transfer Interface (DTI) Autoflame Training 2014.
XAS 375 JD6 Compressors Scott Malm
CUE – Make Any Pump an E-Pump
What is the G.C.S 1. The Cummins Generator Drive Control System (GCS) is a computerized control system used to control a Full Authority Electronic (FAE)
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
BUILDING LOAD NORMAL OPERATION 1. ATS are in normal position connected to utility source 2. All generator set paralleling circuit breaker open.
SGC-250 Synchronous Generator Controller
TPS - Thyristor Power Supply for Resistive/Inductive Loads
Lesson 16: Asynchronous Generators/Induction Generators
Understanding Olympian Generator Set Schematics
FEEDER PROTECTION UNIT
MOTOR PROTECTION SYSTEM
ICP DAS Power Monitor and Management Solution 2016,03,28
Protection Philosophy
Vibration Monitoring System M14
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
easYgen-3000XT Series Training
easYgen-3000XT Series Training
Presentation transcript:

Introducing GAC’s New Line of Intelligent Generator Set Controllers

The InteliGen Stand-By, Prime Mover (single and multiple set), and Parralel to Utility (single and multiple set) Applications Features: 128 x 64 LCD 9 / 9 Discrete Inputs and Outputs (Configurable) Expandable to 21 / 21 3 Analog Inputs (Fuel Level, Coolant Temp., Oil Press.) Expandable to 7 and 1 Analog Output Speed Measurement (Mag Pick-Up) 3 Phase Generator / Utility Voltage Measurement 3 Phase Generator Current Measurement 1 CT Input for Utility Measurement or Earth Fault Protection RS232 for Direct Communication Meets NFPA110 (w/ Annunciator Module iGL-RA15) Remote Communication (Analog, Internet, and GSM)

InteliGen Connections 3 Phase Utility Voltage 3 Phase Generator Voltage 9 Configurable Discrete Inputs and Current Connection for IOM / COM Module Connection for Power Modules Mag. Pick-up 3 Analog Inputs (Oil, Temp., Fuel.) Direct PC or Modem Connection Utility Current 2 Relay Outputs (Starter, Fuel Solenoid) 7 Config. Outputs 12 or 24 V DC

InteliGen’s Modules Sharing) AVR control (needs 18 V AC power supply) Power Control Modules: PCM and PCLSM (with Load Sharing) AVR control (needs 18 V AC power supply) Communications Expandable I / O Modem Support (multiple set applications)

Power Control Modules Shielded Analog Load Sharing Line (PCLSM only) Governor Control Output AVRi Output Mounts Directly to Back of InteliGen 4 Discrete Inputs 12 or 24 V DC 4 Discrete Outputs

Output Level Adjustment (turn pot) AVRi Module Output Level Adjustment (turn pot) 18 V AC Power Supply Output for AVR Control Input from PCLSM DIN Rail Mounting

Communication Module Used for Multiple Set Applications Communications Between Sets Mount: Back of InteliGen Up to 32 Sets Use one Modem (w/iG-MU) RS232 port for IOM

IOM / PTM Module 9 Discrete Inputs w/ Active LED 4 Analog Inputs* 1 Analog Output RS232 for Direct PC Connection RS232 Connection to InteliGen 9 Discrete Outputs w/ Active LED 12 or 24 V DC w/ Power LED DIN Rail Mounting

InteliMains: InteliGen With Special Software Mains (= Utility) Circuit Breaker Control Reverse Synchronization Vector surge protection (locally required) Power Management - Engine Usage Optimization Number of running engines: Dependent on required load Engine starting order: Dependent on running hours Import/Export Control

Parallel To Utility & Other Gen Set’s InteliMains G + iG-COM + iG-PCLSM iG-PCLSM iG-COM G + iG-COM + iG-PCLSM iG-PCLSM iG-COM

InteliGen’s User Friendly Operating Software Setpoints Controller Free User Friendly PC Format History Values

Value Screen Values in Real Time. Screen Selection Metering All Metered Values in Real Time. Metering Screen Selection

History Every Action Logged All Values Associated w/ that Action Up to 177 events (FIFO)

Controller Same as Keypad Essential Metering Alarm List

Setpoints Change any Setpoint Current Value Range Value Screen Selection Acceptable Range for Parameter

Customizable Software Parameters Nominal RPM 80  300 Multilingual Texts Overspeed Überdrehzahl Sobrevelocidad Units °C F; kPa bar psi Controller Operating Mode SPM  SSB  SPtM  MINT  MEXT Text Water temp Coolant temp

Modem connection to remote monitoring* SMS (Mobile phones) connection* Communications Local connection to the Control System Modem connection to remote monitoring* SMS (Mobile phones) connection* Internet connection*

Controller Screens Analog Meters Bar Graphs Numeric Values Controller Screens Allow for Similar Interface as WinEdit Software MAINS: 230 228 233V 50.0Hz GENERATOR: 1517RPM 221 223 220V 50.6Hz 872 896 932A 0.98L 183 194 208kW 118kVAr Running in Island Water Temp 91°C Oil Pressure 5.1bar Fuel level 75% Battery voltage 25.2V

Setpoint Adjustment Three Level Password Protection Adjustable via iG Keypad Three Level Password Protection PARAMETERS MF-Start Delay 3s Start Attempts 5 Mains OK-Delay 10s Cooling time 30s

History Screens as well as WinEdit Viewed on Multiple Screens History Events Can be Viewed From iG Screens as well as WinEdit Viewed on Multiple Screens -15 FINISHED HOUR 07:00:00 16.10. -16 GCB CLOSED-ISLAND 06:23:53 16.10. -17 ENGINE START 06:23:49 16.10. -18 MF-MCB OPENED 06:23:44 16.10. 85kW 1503RPM 0.81L 88C 6.1bar 24.9V 84% 50kW 1495RPM 0.72L 25C 5.3bar 24.7V 87% 0kW 0RPM - 22C 0.0bar 25.8V 87% 0kW ORPM - M 0 0 0V 0.0Hz G233 227 229V 50.1Hz G230 228 223V 49.8Hz G 0 0 0V 0.0Hz M190 195 201V 48.7Hz 121 125 124A 62kVAr 27 29 29kW 72 73 71A 48kVAr 17 18 16kW 0 0 0A 0 0 0kW

Protection Handling Adjustable Delay Settings Five Protective Actions Warning Slow stop Shut-down Unloading History Record Reset Function (Horn + Flashing Light)

Protections Voltage and Current Asymmetry OverCurrent OverLoad Generator / Utility Over / Under Voltage and Frequency Voltage and Current Asymmetry OverCurrent OverLoad Excitation Failure Earth Fault Oil Pressure (two level: warning, shutdown) Coolant Temp. (three level: low temp warning, high temp warning, and high temp shutdown) Fuel Level (two level: warning, shutdown) …

Summary The InteliGen Offers the Right Solution for the Application. Never Pay for Unneeded Features. GAC Leaves it up to You to Make the Intelligent Choice!!