PeCOD® COD Analysis COD Results in 15 Minutes. Introduction COD and BOD Standard Method (Dichromate) New PeCOD® COD Method (Photo-Electrochemistry) Comparison.

Slides:



Advertisements
Similar presentations
EO TP3 SAMPLING WASTE DISPOSAL SYSTEMS.
Advertisements

Rapid determination of Biochemical Oxygen Demand (BOD)
Carl Wirdak Occidental Petroleum Corporation GEMI Survey Water Use, Issues & Management March 2001.
Basics on COD measurement
Sampling and Measurement for Volatile Organic Compounds
Lecture 13: Introduction to Environmental Engineering
Simplicity in Water Analysis The Marketing Department 2003.
GENERATION OF ADDITIONAL REVENUE FROM PRODUCTS OF
Introduction to Environmental Engineering Code No. (PE389) Lec. 6.
Cost Effective Municipal ~ Commercial ~ Industrial ~ Residential Wastewater Treatment Solutions 1 Acti-Zyme.
Introduction to Chemistry Activity. SJWP June 18, Fish Kill Scenario There has been a massive fish kill in Lake St. Louis. Your team has been dispatched.
The AFC Process What Is AFC? Key Operations are  Balancing of incoming waste streams  Thermophilic activated sludge (AFC) to oxidise the organic.
Simple, Fast and Accurate Solvent-free Method for Produced Water Process Monitoring.
Module 71 Measurements in Water & Wastewater On completion of this module you should be able to:  Have an understanding of the use of oxygen demand as.
Wastewater Treatment and Permit Compliance  Document Permit issue and expiration date  Document permit requirements  If discharge to city, review.
Antunes Water Filtration Technologies Introduces to You:
Advanced Biochemistry Lab : Determination of Nitrogen and Crude protein Ms. Nadia Amara.
Valdosta State University Experiment 3 Le Chatelier’s Principle Valdosta State University
SPENT CAUSTIC TREATMENT OPTIONS Hadi M. Al-Daghman, 2014
Analytical Chemistry.
COD Not “Cash on Delivery”. Chemical Oxygen Demand Same principle as BOD but different execution. Rather than biologically decompose/oxidize organic waste,
David M. Struve, SFWMD, Meifang Zhou, SFWMD, Tom Baber, Litkenhaus Associates ABSTRACT A remote P analyzer has been designed and optimized using UV/thermal.
Chapter 8: Oxygen Demand It is a measure of the amount of “reduced” organic and inorganic matter in a water Relates to oxygen consumption in a river or.
Chemical Oxygen Demand (COD)
Catalytic wet air oxidation The Budapest University of Technology and Economics Department of Chemical and Environmental Process Engineering Arezoo Mohammad.
Domestic Waste Water Treatment
Introduction: We will start with an overview of treatment processes 1) Why do we treat water and wastewater? The main objectives of the conventional wastewater.
Waste water treatment - Phycoremediation
Verifying the Use of Specific Conductance as a Surrogate for Chloride in Seawater Matrices Rob Mooney Technical Marketing Manager In-Situ ® Inc.
AN ADVANCED URBAN WATER MANAGEMENT CONCEPT: GRAYWATER SEPARATION Sybil Sharvelle September 11, 2008.
Making Waste Productive. Creating Energy from Waste.
Reference system and centralised calibration for milk (payment) testing Dave Barbano Cornell University Ithaca, NY.
TITRATION This involves removing small samples from the reaction mixture at different times and then titrating the sample to determine the concentration.
Treatability Evaluation of Domestic Wastewater for a Rational Selection of Treatment Processes for a Rational Selection of Treatment Processes for Water.
Chemical Oxygen Demand Presentation By Douglas Rittmann, Ph.D., P.E.
SCI-Pak Sustainable and Cleaner production in the manufacturing industries of Pakistan FUNDED BY THE EUROPEAN COMMISSION 1 SCI-Pak Sustainable.
Coulometric Methods A.) Introduction:
Oxygen Demand Objective –To know the different expressions of Oxygen Demand and their chemical basis, –their use in Environmental Engineering, –and the.
ChemScan. com © 2006 ASA, Inc. On-line Nutrient Monitoring Strategies in Eastern US and Canada 2009 Wuhan International Conference on the Environment Wuhan,
Advanced Aeration, Inc. Presentation of Vacuum Bubble ® Technology.
Human Health Risk Assessment due to pharmaceutical chemical (meprobamate) in surface water Advisor- Prepared By-Advisor- Prepared By- Dr. Arun Kumar Sparsh.
Figure 2. Decrease in K and NO 3 over time in (a) AN1, (b) AN2, (c) CA2. Best fit determined by moving average. Potential for using anaerobic settling.
ChemScan ® mini oP Ortho-Phosphate Analyzer (click to advance slides)
Program Objectives n Define “Decontamination”. n Identify the steps in the decon process. n Demonstrate, by building, a decontamination reduction zone.
Organic Matter  Energy for Mircoorganisms
Characteristics of Sewage. Sampling techniques The value of any laboratory result depends on the integrity of the sample. The object of sampling is to.
Green Remediation through Optimization Douglas Sutton, PhD, PE Tetra Tech GEO April 4, 2011.
- 2.2 – ORGANIC MATTER (Diederik Rousseau UNESCO-IHE Institute for Water Education Online Module Water Quality Assessment 2.
By: Tyler Stevens Mikayla Stern-Ellis Zach Jones & Althea.
Prepared by: Pn. Hairul Nazirah Abdul Halim
Membrane Bioreactors for Wastewater Treatment.
Water management company AN ADVANCED SEWAGE WATER TREATMENT CONCEPT: e – IONIZATION TREATMENT.
Presentation to : WERF LIFT Presented by:. Lystek - The Company Low Temperature Chemical Hydrolysis technology installed after dewatering, easy to install.
1 Course TEN-702 Industrial waste management unit-1 Lecture -4 & 5.
Dissolved Oxygen In Water
Product and Application Overview
Lecture (5): lab methods of measurement
Waste Disposal 1- Gas waste air pollution
WASTEWATER CHLORINATION DECHLORINATION MONITORING AND CONTROL PILOT DEMONSTRATION AT CLARKSON AND CITY OF GUELPH ONTARIO WWTPs Wei Zhang1, Jeremy Leverence1,
Principals of Hospital Wastewater Management
Advanced Aeration, Inc. Presentation of Vacuum Bubble® Technology
OXYGEN Dissolved Oxygen (DO) Chemical Oxygen Demand (COD)
Dissolved Oxygen and Biochemical Oxygen Demand Analyses
Chapter 21 Water Pollution and Treatment
Introduction If nontoxic organic pollutants get discharged into a river, lake or stream, they should be pretty harmless, right?
Chilean Mill uses PeCOD® COD Analyzer for Determination of Chemical Oxygen Demand (COD) for Savings in Bleaching Process.
CLEANING VALIDATION FOOD & BEVERAGE –– WASTEWATER –– LABORATORY –– PHARMACEUTICAL & MEDICAL DEVICE.
Christof Mainz European Commission
강의자료 ppt-11 인간의 삶과 역사 속의 미생물 학기.
Characteristics of Sewage
Presentation transcript:

PeCOD® COD Analysis COD Results in 15 Minutes

Introduction COD and BOD Standard Method (Dichromate) New PeCOD® COD Method (Photo-Electrochemistry) Comparison of COD Methods PeCOD Applications Conclusion

About MANTECH Manufacturer of laboratory instrumentation solutions: Automated multi-parameter Titration Biochemical Oxygen Demand (BOD) Chemical Oxygen Demand (COD)

COD and BOD Biochemical Oxygen Demand (BOD) and Chemical Oxygen Demand (COD) are ubiquitous measurements of overall water quality. Among the most diagnostic parameters for the determination of water quality in natural waterways and waste streams. COD measures the equivalent amount of oxygen required to chemically oxidize the organic compounds in water BOD measures the equivalent amount of oxygen required to biologically (microbes) oxidize the organic compounds in water

COD and BOD The standard BOD test requires five days to complete - unable to provide continuous monitoring of organic load. COD is often used for BOD screening. Both involve a 2 step process: Step 1 - Oxidation of organic matter Step 2 - Measurement of extent of oxidation

Standard COD Method (Dichromate) Uses hazardous chemicals (dichromate, concentrated acid, mercury) to oxidize organic carbon in water into CO ­­ 2 and H 2 O. Samples are digested at 150°C, 2-3 hour process with cooling time The oxygen demand is determined by the amount of oxidant consumed, using a spectrophotometer or titration method. Overall measurement uncertainty, ≈ ±20-30 %

PeCOD® COD Analysis PeCOD is a new technology which measures soluble COD in various water samples. Directly measures photocurrent/charge originating from the oxidization of the organic contamination in a test sample. A UV-activated nanoparticle TiO2 (titanium dioxide) photocatalyst coupled to an external circuit. High Oxidation Potential (3.2eV) vs (1.6eV) for Dichromate

PeCOD® COD Analysis Overcomes many of the problems encountered by existing COD analysis methods Fastest available method – results in only 15 minutes Does not use dichromate or other hazardous reagents Can be used by all operations staff Excellent BOD screening tool

“The new approach for measuring chemical oxygen demand by photo-electrochemical measurement eliminates the use of corrosive (H 2 SO 4 ), carcinogenic (K 2 Cr 2 O 7 ), toxic (HgSO4) and irritant (Ag 2 SO 4 ) chemicals for the analysis of chemical oxygen demand. Analysis time was significantly reduced and the method detection limit was 1 mg/L O 2. ” Vasile Furdui, Ph.D. Research Scientist, Ministry of the Environment and Climate Change.

Simplified Analysis Approach Easy to use, “click and go” interface menu for all operations – analysis, calibration, flushing. Enhanced software package enables additional functionality, parameter sampling and reporting. Small unit footprint requires minimal bench space (235 x 375 mm) and is light weight (5 kg).

Nanotechnology based approach Patented sensor consists of a UV-activated TiO2 (titanium dioxide) photocatalyst Powerful oxidizing potential of TiO2 gives a true measure of COD COD analysis method of Ontario Ministry of Environment (method E3515) COD analysis can now be done by any operations staff member

PeCOD® Applications Municipal Incoming COD monitoring In-plant COD monitoring Wet weather events Discharge compliance Potable water analysis Industrial In-plant COD monitoring Process optimization Discharge compliance Fine avoidance Laboratory COD analysis Multi-parameter Speed and accuracy Safety of employees

“We moved from the COD vials to the PeCOD® primarily because it allowed us to run our process more efficiently and further adjustments to our process could be made up to ten times a day. With the COD vials, only 3 or 4 adjustments could be made. This increase in efficiency, not to mention the added benefit that we're no longer using carcinogenic chemicals to test for COD. We have also seen a reduction in cost of consumables and waste disposal.” Mark Westhorpe, Analytical Shift Leader, Vertellus Specialty Materials based in the United Kingdom.

Plot of PeCOD COD (green range) and dichromate COD (low range vials) for various filtered waste water samples from various sampling locations (round 2 of testing). City of Guelph WWTP

Scatter plot of PeCOD COD (green range) and dichromate COD (low range vials) for various filtered waste water samples. Strong Correlation for Waste Water

Scatter plot of PeCOD COD (red range) and dichromate COD for treated effluent samples analyzed by Clean Harbors (waste treatment facility) Strong Correlation for Waste Water

Plot of PeCOD COD, soluble dichromate COD and total dichromate COD for surface water samples from the Athabasca watershed in Alberta, Canada. Effective Surface Water Monitoring

Scatter plot of PeCOD COD against total dichromate COD for surface water samples from the Athabasca watershed in Alberta, Canada. Strong Correlation for Surface Water

Scatter plot of PeCOD COD (green range) and dichromate COD for 68 surface water samples analyzed by the MOE Strong Correlation for Surface Water

More Effective Potable Water Analysis Dalhousie University study With PeCOD® analysis, removal of NOM is approximately 3.5x greater vs use of traditional surrogates such as TOC and DOC PeCOD® has expanded resolution, even when NOM removal is small Significant advantage of a rapid response time for analysis results Ideal for processes such as biofiltration and advanced oxidation that require more understanding of NOM removal

Scatter plot of PeCOD COD (blue range) and TOC for various reference compounds analyzed by Dalhousie University Strong Correlation for Potable Waters

Conclusion Overcomes the weaknesses of traditional COD analysis Results in only 15 minutes No use of dichromate or harmful reagents Easy to use system for all operations staff Nanotechnology provides more accurate measure of COD Excellent screening tool for BOD and high potential for NOM Recognized and used by the Ontario Ministry of Environment