Chapter 8: Oxygen Demand It is a measure of the amount of “reduced” organic and inorganic matter in a water Relates to oxygen consumption in a river or.

Similar presentations


Presentation on theme: "Chapter 8: Oxygen Demand It is a measure of the amount of “reduced” organic and inorganic matter in a water Relates to oxygen consumption in a river or."— Presentation transcript:

1 Chapter 8: Oxygen Demand It is a measure of the amount of “reduced” organic and inorganic matter in a water Relates to oxygen consumption in a river or lake as a result of a pollution discharge Measured in several ways –BOD - Biochemical Oxygen Demand –COD - Chemical Oxygen Demand –ThOD - Theoretical Oxygen Demand

2 Theoretical Oxygen Demand C 6 H 12 O 6 + 6O 2 = 6CO 2 + 6H 2 O Oxygen Demand 6moles*32g/mole Oxygen/1mole*180g/mole = 1.06 O 2 / Glucose = 1.06 O 2 / Glucose If glucose concentration is 360 mg/L THOD is 1.06 * 360 mg/L = 384 mg/L Oxygen

3 BOD: A Bioassay Briefly, the BOD test employs a bacterial seed to catalyze the oxidation of 300 mL of full-strength or diluted wastewater. The strength of the un-diluted wastewater is then determined from the dilution factor and the difference between the initial D.O. and the final D.O. BOD Bottle

4 BOD with Dilution Where BOD t =biochemical oxygen demand at t days, [mg/L] DO i =initial dissolved oxygen in the sample bottle, [mg/L] DO f =final dissolved oxygen in the sample bottle, [mg/L] V b =sample bottle volume, usually 300 or 250 mL, [mL] V s =sample volume, [mL] When BOD>8mg/L

5 BOD - loss of biodegradable organic matter (oxygen demand) LoLo LtLt L or BOD remaining Time L o -L t = BOD t BOD Bottle BOD Bottle BOD Bottle BOD Bottle BOD Bottle

6 BOD L=oxidizable carbonaceous material remaining to be oxidized

7 BOD Modeling "L" is modelled as a simple 1st order decay: Which leads to: We get: And combining with:

8 NBOD Nitrogeneous BOD (NBOD) 2 moles oxygen/1 mole of ammonia 4.57 grams oxygen/gram ammonia-nitrogen Inorganic NH 3, NO 3 - NO 2 - Organic Proteins, Amino acids TKN = Ammonia-N + Organic Nitrogen

9 COD: A chemical test The chemical oxygen demand (COD) of a waste is measured in terms of the amount of potassium dichromate (K 2 Cr 2 O 7 ) reduced by the sample during 2 hr of reflux in a medium of boiling, 50% H 2 SO 4 and in the presence of a Ag 2 SO 4 catalyst.

10 Solids: significance TDS: used as a measure of inorganic salt content in drinking waters and natural waters TSS: used to assess clarifier performance VSS: used to estimate bacterial populations in wastewater treatment systems

11 Solids Analysis

12 Filtration for Solids Analysis 3. Start suction pump 2. Pour Sample 1. Weigh new filter and insert 4. Remove filter and re-weigh 6. Divide this by the Volume filtered and you get TSS 5. Measure Change in Weight Suction Flask & Filter Holder