Global Lift Corp ADA Laws & Commercial Series Lifts.

Slides:



Advertisements
Similar presentations
HEAVY-DUTY FASTENER SYSTEMS
Advertisements

Hoshizaki America has built a legacy of quality design, reliability and customer commitment. In our Commercial Series refrigeration line, youll see solutions.
Tri-Tech Medical Inc. Medical Gas Outlets.
LadderPort ™ LadderPort™, the inexpensive permanent building mounted extension ladder receiver, securely holds the ladder in place. Hooks secure the ladder.
Light Weight Portable Cranes
GLOBAL LIFT CORP COMMERCIAL SERIES PORTABLE KIT Portable Kit -
LIGHT-DUTY BELT FASTENER SYSTEMS
Bob cat Skid steer loader
2.5.2 Student Book © 2004 Propane Education & Research CouncilPage Examining, Maintaining and Operating ASME Tank Setting Trailers For the safe.
Connector Installation Guide For Compression and Mechanical Connectors
Moments of Inertia Polar moment of inertia – Used when calculating the torsion – Indication of resistance to torsion – Solid Shaft – J = π R 4 / 2 Area.
Concrete Pre Cast Panel By Peter Spence ID:
The Load Bank of Choice
Private Stairway A private stairway is a series of steps with straight nosings on plan intended for use solely in connection with one dwelling. Tread Newel.
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Maintenance of Traffic (MOT)
Universal Designers & Consultants, Inc. The Effect of the DOJ’s Newly Proposed ADA Standards (2004 ADAAG) on Hotel Design Universal.
Chapter 3: Scaffold Safety
+ SCOPE INDUSTRIAL PRODUCTS PRIVATE LIMITED Corporate Presentation March 2014.
Foundation Systems.
Roofing Fall Protection The following presentation can be used to satisfy the training requirements of the Fall Protection Standard in the WISHA Safety.
LADDER SAFETY.
Global Lift Corp Understands that there will many questions Asked in regards to ADA Laws, this will guide you along The way of.
SimTek Fence. About Us Founded in 2007, SimTek Fence has reinvented fence manufacturing with its patented design of rotationally-molded.
Subpart X-Stairways & Ladders
Fall Protection in the Roofing Industry
Capital Safety Inc–Confidential CNA Roofer’s Summit.
Tie-Off Points and Anchors Presented by Scott Pipicelli – HC&A.
The State of Ohio is an Equal Opportunity Employer and Provider of ADA Services Engineering and Design Considerations for the Americans with Disabilities.
CONSTRUCTING A FIVE CABIN LATRINE
Open Frame Racks & Accessories. 2 Application ‣ 2/4-Post Open Frame Racks combine the mounting security of a cabinet with the accessibility of a rack.
Suntraders Company Ltd. / Anthony Kent Gibbons Industrial Park, Christ Church, Barbados BB17101 (246) Fax: (246)
COMMERCIAL SERIES TRI-POINT ANCHORING SYSTEM
Appendices Subpart R Steel Erection
Americans with Disabilities Act Status Update What All Camp Directors Need to Know Presented by Jennifer K. Skulski National Center on Accessibility
DROP IN ANCHOR DETAIL COMMERCIAL SERIES LIFTS INSTALLATION MANUAL Drop In Anchor/COMMERCIAL SERIES.
Nautilus Hyosung / Confidential May 17, 2011 Rob Evans, Product Management Nautilus Hyosung America 2010 ADAAG Standards & Your ATM Program.
How to Build Your Playhouse. September 08, 2006 By Kay Adams, Tamecha Buck, Janet Herron & Lisa Weston “Click on pictures”
Plain & Reinforced Concrete-1 CE-313
Multiple Coil Lift Calculation. Purposes of the Study  To investigate the stress distribution in the MCWF and the lifting device.  To make sure mounting.
Wall and Ceiling Construction
RLP Installation. RLP Approvals Most Servicing Railroads and ALL Class 1’s (excluding CSX) Require that the scale design, location and functionality be.
1 ADA EZ Product Review Meeting Presented by Jay Vaitkus.
Design Partition, Project Plan, Task Assignments and Conceptual Designs September 13, 2006 Team Moondogs Chris Culver Rahul Kirtikar Elias Krauklis Christopher.
INTD 54 other components. moldings cover, enhance and decorate a plain surface standing trim: fixed length—doors & windows.
Statistics U.S. Department of Labor – Bureau of Labor Statistics Statistics.
Flat Saw Training. Flat Saw Sizes –Low Horsepower Blade diameters range from 8” (200mm) to 18” (450mm) Power ranges from 4 to 25 horsepower.
P09011 – Object Recognition - 1/9/2009. Functional Decomposition, Simplified by System Connecting Object Method Apparatus Connection Device Object Connection.
GLAST LAT ProjectDOE/NASA Mechanical Systems Peer Review, March 27, 2003 Section Mechanical Systems Radiator Assy1 GLAST Large Area Telescope: Mechanical.
Texonics Proposal for Production Line Redesign and Retrofit.
POST LIFT FEATURES, BENEFITS AND APPLICATTIONS POST MATERIAL HANDLING MANUFACTURES LIFTING DEVICES TO POSITION MATERIALS AND EQUIPMENT FOR PROCESSING.
Problem Statement & Conceptual Designs September 6, 2006 Team Moondogs Chris Culver Rahul Kirtikar Elias Krauklis Christopher Sampson Michael Widerquist.
Sprinkler Loads on Trusses
1  2008 Kaeser Compressors, Inc., USA (V2.2) “Specifications are subject to change without notice” Presenting... Kaeser Omega Blowers.
1/20/2016Minimizer Confidential1. 21/20/2016Minimizer Confidential.
Last-Deck® was invented and designed by Last-Deck® company president Doug Deel. Doug has over 25 years of experience in the custom building industry, specifically.
Fall Protection Sub-committee Update
COMPACTION BY EQUIPMENTS
Minimizer Confidential
UPDATE ON DOE RUN ELEMENTARY CONSTRUCTION PROGRESS
Zurn Fire Valves - Overview 101
ActivRAC® 16P Mobilized Storage System
The Froet Drain® Roof Drain
ActivRAC® 7M Mobilized Storage System
ActivRACTM 30P Mobilized Storage System
ESS Concrete Pit Lids.
Fall Protection Sub-committee Update
Self-sealing Cable Transit Panel Project Update
Keeping things together since 1922
Stoughton Parts Sales 2019 Customer Appreciation Event
Presentation transcript:

Global Lift Corp ADA Laws & Commercial Series Lifts

New ADA Laws On July 26, 2010, the US Department of Justice released updated ADA Standards for Accessible Design. Among the updates are new requirements specifically for public swimming pools. The level of accessibility depends on the size and type of the pool. The law became in effect on September 15, The compliance took effect on March 15, 2011 Existing pools shall become compliant with accessibility by March 15, 2012

Determining What the Means of Access Swimming Pools. At least two (2) accessible means of entry shall be provided for swimming pools Pool lifts comply with Sloped entries comply with Transfer walls comply with Transfer systems comply with & 6 & Pool stairs comply with

242.3 Wading Pools. At Least (1) one accessible means of entry shall provide for wading pools. Accessible means of entry shall comply with sloped entries At least one accessible means of entry provided shall comply with or Spas. At least one (1) accessible means of entry shall be provided for spas. Accessible means of entry shall comply with swimming pool lifts complying with ; Transfer walls complying with ; Or transfer systems complying with

Pools under ADA Regulations fall under either: Title II (Public Industry) municipal pools, school pools, government owned pools, etc. Title III (Private Industry) place of recreation, place of lodging, which addresses public accommodations

Pool having less than 300 linear feet of swimming pool wall, no more than one accessible means of entry shall be required. Pools having more than 300 linear feet must have 2 means of entry. Wave action pools, leisure rivers, sand bottom pools, and other pools where access is limited to one area shall not be required to provide more than one accessible means of entry. Catch pools shall not be required to provide an accessible means of entry. Where spas are provided in a cluster, no more than 5%, but no fewer than one, spas in each cluster shall be required to comply with 242.4

Can multiple pools/ spas at a facility share a lift The standards require that each operational pool be accessible. Sharing a lift does not satisfy the standards and may create safety issues with stranded swimmers if the lift is moved while they are in the pool.

What Makes A Lift ADA Compliant? Here are some basics to check on your lift. 1. Lift must have a capacity of 300 lbs or more. 2. Lift must have a solid seat and a footrest. Sling seat styles are not compliant and should be replaced. 3. Lift must be self operable from the deck and the water. A lift with manual rotate or hand crank is not compliant and should be replaced. There are also specific requirements for clear deck space and water depths.

Advisory Lifting Capacity. Single person pool lifts must be capable of supporting a minimum weight of 300 pounds Sustaining a static load of at least 1.5 times the rated load. Pool lifts should be provided that meet the needs of the population they serve. Providing a pool lift with a weight capacity greater than 300 pounds may be advisable.

Our Lifts are Made in the USA Companies founders have over 100 years combined experience in manufacturing Global Lift Corp’s Commercial Pool Lifts meet or exceed all of ADA’s requirements and regulations

Commercial/Proformance Series Lifts Standard Features ADA Compliant Pool Lift Stainless Steel Construction Powder Coat Finish Lift Capacity – 3 Separate Models that range from 350 to 450 lbs Internal Seat Leveling System (patent pending) Battery Powered 24 volt system Easy controls Portable Capability System (patent pending) Lifetime Structural Warranty Tri-Point Custom Anchor System (patent pending) Arm Rests Foot Rest Safety Seat Belt UPS Packaging for easy shipping Commercial Grade Construction Right or Left Seat Position Easily upgradeable to different weight Lifts can be used in Spas and Pools

TRI-POINT ANCHORING SYSTEM INSTALLATION COMMERCIAL SERIES Patent Pending PARTS LIST 1 - Anchor Plate 3 - Stainless Steel Bolts 3 - Threaded Anchor’s

ANCHORING PLATE, ANCHORS & BONDING LUG 5/8’s Bolts

TRI POINT ANCHOR INSTALLATION – COMMERCIAL SERIES Anchor Plate’s front edge should be no closer than 17” to the pool wall Attach copper wire to the bonding lug and then to your bonding grid Cold Pin’s should be ½” rebar 6” to 8” long SAND 6” 3’ Concrete Cold Pin 5/8 Bolts Bonding Lug Water Pool Wall 6” Threaded Anchor’s 3’ Anchor Plate Overview Section Detail Minimum Distance From pool wall 17”

COMMERCIAL SERIES LIFT INSTALLATION Unit’s front hinge point shall not be farther than 14” to the pool’s edge Place unit over the anchor holes and place the stainless steel bolts in and tighten down POOL WALL WATER Front Hinge Point 14” POOL LIFT Anchor Bolts