Engineer Training Troubleshooting TJ8300 / TJ8500 Troubleshooting.

Slides:



Advertisements
Similar presentations
Service Section Technical Training.
Advertisements

Engineer Training Machine Electrical Cabinet TJ8300 / TJ8500 Machine Electrical Cabinet (EC)
Engineer Training UV Lamp Head TJ8300 / TJ8500 UV Lamp Head.
Engineer Training XL1200 Safety System. Engineer Training XL1200 Safety System Confidential 2 Standard Requirements Both the machine and the Safety System.
Engineer Training Installing the UV Lamp TJ8300 / TJ8500 Installing the UV Lamp.
Engineer Training XL1200 Pneumatics. Engineer Training XL1200 Pneumatics Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:
Engineer Training XL1200 Ink System. Engineer Training XL1200 Ink System Confidential 2 Ink System The XL1200 Ink System consists of the following elements:
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Engineer Training Supply Unit TJ8300 / TJ8500 Supply Unit.
Engineer Training XL1200 Electronics. Engineer Training XL1200 Electronics Confidential 2 XL1200 Electronics The XL Jet Electronic System consists of.
AC-SSC-1 Installation and operation manual
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
In this presentation you will:
Engineer Training General Safety TJ8300 / TJ8500 General Safety.
Engineer Training Inkjet Head Cleaning TJ8300 / TJ8500 Inkjet Head Cleaning.
Engineer Training Control Unit TJ8300 / TJ8500 Control Unit.
Air-Conditioning Control Systems
Engineer Training Rear Operation Unit TJ8300 / TJ8500 Rear Operation Unit.
Oxygen Concentrators.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
GO ORDNANCE !!! ORDNANCECORPS 1 Antenna Mast Group We will now trace the electrical circuits of the antenna mast mast group. Be fore we get started you.
Engineer Training TN 59 Ink Management Solution TJ8300 / TJ8500 TN 59 Ink Management Solution Machine 75 and Above.
Hydraulic Anti-Lock Braking System For Trucks, Buses and Motor Homes.
Engineer Training XL1500 Safety System. Engineer Training XL1500 Safety System Confidential 2 Standard Requirements Both the machine and the Safety System.
Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Electrical Cabinet (EC)
Engineer Training Electrical System Overview and Requirements.
Pump Application Interface. 30 October 2006 Overview Increases the functionality of the soft starter for pumping applications - four additional trip inputs.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
Engineer Training Electronic System Overview. Engineer Training XL1500 Electronics Confidential 2 XLjet Electronics The XL1500 Electronic System consists.
Troubleshooting Electric Control Devices
Industrial Machine Control
Engineer Training Startup/Shutdown Procedures TJ8300 / TJ8500 Startup/Shutdown Procedures.
HYDRONIC HEATING AQUASTATS
Engineer Training XL1200 Electric. Engineer Training XL1200 Electric Confidential 2 Block Diagram.
Engineer Training Machine New Features TJ8300 / TJ8500 Machine New Features.
Settings & Adjustments. Settings & Adjustments.
Air Handler Terminology
Electric Circuits17.4. Electrical Safety Tips Make sure insulation on cords is not worn Do not overload circuits Do not use electrical devices while hands.
Engineer Training Cooler TJ8300 / TJ8500 Cooler. Engineer Training Cooler TJ8300 / TJ8500 Confidential 2 Introduction.
Engineer Training RTRun – Real Time Software TJ8300 / TJ8500 RTRun – Real Time Software.
Engineer Training Pneumatic System Overview. Engineer Training Confidential 2 Working Concept Overview: The Pneumatic System is comprised of:  Y Pistons.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
Engineer Training Ink Insertion TJ8300 / TJ8500 Ink Insertion.
Engineer Training Checking the Motor’s Rotation Direction TJ8300 / TJ8500 Checking the Motor’s Rotation Direction.
Interactive Control in Engineering Projects Electronics and Control.
Prepared by: Engr. Qurban Ali Memon 11ES (SEC- 1 & 2)
52 RCACS Ground School Engines PO 407 EO 4 “Fuel Problems, Ignition, and Basic Electrical System”
ADT490 TroubleShooting Locating Opens A. 2 Introduction Breakdown in Circuit Integrity -> Trouble Metallic continuity interrupted an “ open ” occurs System.
DT Shifter Training Infrastructure A. Benvenuti, M.Giunta 07/07/2010.
TEST PROCEDURE Testing the Controller Board, Power Supply Board, and Unit as a Whole.
Engineer Training Drying System, IR and Temp Control.
19.2 Domestic electricity Paying for electrical energy  Most of the electrical appliances in your home use mains electricity.  Mains electricity: alternating.
Control Systems: Circuitry Electricity for Refrigeration, Heating and Air Conditioning 7th Edition Chapter 16 Control Systems: Circuitry and Troubleshooting.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
Topic: Electrical Circuits PSSA: B / S8.C.2.1.
AIR CONDITIONING (COOLING)
FIRST ROBOTICS COMPETETION Introduction to Electrical & Control System Power and Signal Distribution/Interconnection Sensors, Motors, Speed Controllers,
Circuits.
CUT40P training manual March.2011.
Unit 37: Fluid containment Dr
Section 6: Air-Conditioning (Heating And Humidification)
UV Startup Procedure.
Qualified Electrical Worker
Unit 37: Fluid containment Dr
Fuel Supply System Service
Practical electricity
MINNY 16 TROUBLESHOOTING Doc THE MACHINE DOES NOT START
Presentation transcript:

Engineer Training Troubleshooting TJ8300 / TJ8500 Troubleshooting

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 2 General  When an alarm message/fault occurs, the UV lamp switches off and cools down for 2 minutes before re-starting.  Clearing the alarm message is done from the RTRun software: Tools > UV Dryer > UV Alarm On/Off

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 3 Alarm Messages Machine Emergency Stop:  An Emergency stop has occurred on the machine.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 4 Alarm Messages (Cont.) Shutter Failed to Close:

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 5 Alarm Messages (Cont.) Shutter Failed to Close (Cont.):  Check that the UV lamp plug is connected to XPPT.  Check that the pneumatic air tube is connected to lamp head.  Check the shutter switch inside the lamp head and all electrical connections/wiring.  Check the 24VDC power supply in the UV electrical cabinet.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 6 Alarm Messages (Cont.) Shutter Failed to Open:

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 7 Alarm Messages (Cont.) Shutter Failed to Open (Cont.):  Check that the UV lamp plug is connected to XPPT.  Check that the pneumatic air tube is connected to lamp head.  Check the shutter switch inside the lamp head and all electrical connections/wiring.  Check the 24VDC power supply in the UV electrical cabinet.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 8 Alarm Messages (Cont.) Lamp Over Temperature: Lamp

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 9 Alarm Messages (Cont.) Lamp Over Temperature (Cont.):  Check that the UV lamp plug is connected to XPPT.  Check that the water tubes are connected and that the cooler is running, without any problems.  Check the electrical connections and wiring.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 10 Alarm Messages (Cont.) Lamp Power Fault: Lamp

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 11 Alarm Messages (Cont.) Lamp Power Fault (Cont.):  During the lamp’s “burn-in” stage, if its current does not exceed 70A after 2 minutes, the lamp switches off and the alarm message appears.  Check the connection between the UV lamp head and the UV electrical cabinet.  Check if the lamp is not broken.  Verify that the four high voltage relays in the UV electrical cabinet are enabled during the “burn-In” stage.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 12 Alarm Messages (Cont.) Lamp Pressure Alarm: Lamp

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 13 Alarm Messages (Cont.) Lamp Pressure Alarm (Cont.):  Verify that the extraction fan ducts, on top of the lamp head, are secured.  Verify that the extraction fan rotates in clockwise direction.  Check the electrical connections and wiring.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 14 Alarm Messages (Cont.) Extract Fan Trip:

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 15 Alarm Messages (Cont.) Extract Fan Trip (Cont.):  Verify that the fan circuit breaker (Q7 inside the UV electrical cabinet) is On.  Check all electrical connections and wiring.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 16 Alarm Messages (Cont.) Cooler Pump/Fan Trip:

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 17 Alarm Messages (Cont.) Cooler Pump/Fan Trip (Cont.):  Verify that the cooler pump circuit breaker (Q6.11 inside the UV electrical cabinet) is On.  Verify that the cooler Fan 1 circuit breaker (Q6.12 inside the UV electrical cabinet) is On.  Verify that the cooler Fan 2 circuit breaker (Q6.13 inside the UV electrical cabinet) is On.  Check the electrical connections and wiring of plug XPC2 (from cooler to UV electrical cabinet).

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 18 Alarm Messages (Cont.) Cooler Over Temperature:

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 19 Alarm Messages (Cont.) Cooler Over Temperature (Cont.):  Verify that all water connections are secure and there are no leaks.  Check the temperature switch connections and wiring.  Check the electrical connections and wiring of plug XPC2 (from cooler to UV electrical cabinet).  Check all electrical connections and wiring.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 20 Alarm Messages (Cont.) Cooler Low Level:

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 21 Alarm Messages (Cont.) Cooler Low Level (Cont.):  Check the cooler’s water level.  Verify that all water connections are secure and there are no leaks.  Check the electrical connections and wiring of plug XPC2 (from cooler to UV electrical cabinet).  Check all electrical connections and wiring.

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 22 Alarm Messages (Cont.) Reflector Open Check Lamp Safety Switch:

Engineer Training Troubleshooting TJ8300 / TJ8500 Confidential 23 Alarm Messages (Cont.) Reflector Open Check Lamp Safety Switch (Cont.):  Verify that the lamp reflector is in closed position.  Check the safety switch and the electrical connections and wiring of plug XPLH (from the UV lamp head to UV electrical cabinet).  Verify that the safety relay K9 is energized and green LED is lit. If the orange LED is lit, the safety relay is not energized.