Langley City Fire & Rescue Ground Ladders. Objectives Meet the standards for Firefighter I as outlined in Chapter 3 NFPA 1001, 1997 Candidates be able.

Slides:



Advertisements
Similar presentations
Ground Ladders.
Advertisements

Firefighter III Ladders Lt. Rick Decorie.
35 FOOT LADDER 3 PERSON.
Workers Compensation Ladder Safety Training
F&T Inc. OVERHEAD CRANE SAFETY.
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
What Goes Up… Must Come Down Portable Ladder Safety
CVFD Training – Ladder Practices
Ladder Safety Today’s topic is Ladder Safety. This training is a part of OSHA’s Portable Wood and Metal Ladder Safety Standards (29 CFR ). You.
Ladder Safety Today’s topic is Ladder Safety. This training is a part of OSHA’s Portable Wood and Metal Ladder Safety Standards (29 CFR ). You.
1 Risk Management Department Ladder Safety July, 2006.
Intermediate SFFMA Objectives: – hrs received.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
North Idaho Emergency Services Academy. Objectives Types of fire service laddersTypes of fire service ladders Ladder termsLadder terms Ladder raising.
Stairways and Ladders 1926 Subpart X - Stairways and Ladders
Stairways & Ladders
Firefighter III Module A Ladders (4-11).
CHAPTER 14 LADDERS Copyright© Delmar is a division of Thomson Learning.
Robert Sepulveda, VFA Instructor
Chapter 10 Lesson Goal After completing this lesson, the student shall be able to safely and effectively select, carry, raise, and work from ladders following.
Ladder Safety Today’s topic is Ladder Safety. This training is a part of OSHA’s Portable Wood and Metal Ladder Safety Standards (29 CFR ). You.
Fire Service Ladders. Main Topics Basic Parts of a Ladders Basic Parts of a Ladders Ladder Types Ladder Types Ladder Raises Ladder Raises Ladder Positioning.
Ladder Safety. Each year, more than 511,000 people are treated in hospital emergency rooms, doctors' offices, clinics and other medical settings because.
Fort McCoy Safety Industrial Operations Program Ladder Safety June 2002.
Categories of Aerial Ladders Aerial Ladders Aerial Platforms Telescoping Aerial Platform Tele-Squirt Articulating Aerial Platform Quint.
STEP-BY-STEP LADDER SAFETY By Louisville Ladder Corporation.
Summit’s “TOOLBOX SAFETY TALK”
Ladder Safety Training
Ladders Can take you… to great heights or on a quick trip to the ground.
Climbing the Ladder to Safety
SAFETY TALK - SLIDE 1 OF 10 Elkhart Products Corporation 02/00 WELCOME THANKS TO ELKHART PRODUCTS CORPORATION FOR THIS “TOOLBOX SAFETY TALK” OSHA 29 CFR.
Ladders Module III. Ladder Construction Materials Metal Wood Fiberglass.
Ladders Skill Drills.
LADDER SAFETY.
CHAPTER 14 Copyright © 2007 Thomson Delmar Learning 14.1 Ladders.
5/18/2015Dixon High School Fire Department1 Introduction The Recruit will also practice and masters certain skills and will be tested on these skills.
Ladder Safety Training. Agenda Awareness/Statistics General Condition Duty Rating Proper Use Proper Ladder Length.
Chapter 14 Ladders.
1 Telecom Cabling Ladder safety. 2 OSHA Office of Training & Education ation Telecom Cabling Stairways and Ladders.
LADDERS State of Georgia BASIC FIRE FIGHTER TRAINING COURSE.
Fall Protection and Ladder Safety Training. Course Outline  Introduction  Fall Protection  Ladder Safety  Wrap-up.
FVCC Fire Rescue LADDERS.
CVFD Training – Ladder Practices SFFMA Training Objectives –
Fire Service Ladders Module 1.
4/19/2017 Ground Ladders Brantley County Firefighters Association Monthly Training Conducted by the Atkinson Volunteer Fire Department December 2008 Atkinson.
Aerial Apparatus Operator Types and Construction of Aerial Apparatus.
Chapter 10 Lesson Goal After completing this lesson, the student shall be able to safely and effectively select, carry, raise, and work from ladders following.
FALL PROTECTION. WHY? –BECAUSE: Falls accounted for 10% of fatal work injuries in 1994 & Serious hazards can be present while above ground. –Examples:
Fire Hoses, Nozzles, Portable lighting, appliances, and ladders.
Fire Service Ladders Firefighter II.
12 Ladders Skill Drills. 2 Objectives Perform one-, two-, three- and four-FF carries. Perform one-, two-, three- and four-FF raises. Tie the halyard.
12 Ladders. 2 Objectives List and describe the parts of a ladder. Describe the different types of ladders. Describe how to clean and inspect ladders.
35’ Ladder Beam Raise Two Person Level I 4/1/12. Introduction This presentation demonstrates the basic operation for a two person beam raise. The evolution.
Ladders Module 2. Introduction The fire service ladder is one of the most basic fire fighter tools. Ladder technology has not changed much over the years.
Safety on Call LADDER SAFETY. Safety on Call LADDERS CAN TAKE YOU… To great heights or on a quick trip to the ground.
Ladders.
Ladder Safety. Each year, more than 511,000 people are treated in hospital emergency rooms, doctors' offices, clinics and other medical settings because.
LADDER SAFETY PROGRAM. Ladder Safety “No matter how quickly a job can be done, there is always time to fall”
Photo by University of Houston Digital Library - Creative Commons Attribution-ShareAlike License with.
12 Ladders. 12 Objectives (1 of 2) List and describe the parts of a ladder. Describe the different types of ladders. Describe how to clean, inspect, and.
Ladder Safety Training
ELKHART PRODUCTS CORPORATION
OBJECTIVES List and describe the parts of a ladder.
FVCC Fire Rescue LADDERS PART B.
Ladders and Stairs in Construction
F&T Inc. OVERHEAD CRANE SAFETY.
Ladders Standard 29 CFR Part
Keep Aluminum Ladders Away From Electricity
CHAPTER 11 Ladders 1.
North Carolina Fire & Rescue Commission Ladders I Updated 9/2011
Presentation transcript:

Langley City Fire & Rescue Ground Ladders

Objectives Meet the standards for Firefighter I as outlined in Chapter 3 NFPA 1001, 1997 Candidates be able to identify, carry, raise, climb, inspect, and maintain fire service ground ladders

Purpose Assist in rescue Access upper levels Elevate Master Streams Assist in Ventilation

Parts of a Ladder Beam - Main structural member of a ladder supporting the rungs Bed Section - Lowest and widest section of an extension ladder. Butt/Heel - Bottom end of ladder that contacts ground Butt Spurs - Safety plates or spikes attached to Butt to prevent slippage

Parts of a Ladder Cont. Dogs/Locks/Pawls - Devices attached to beam on fly sections to hold fly sections in place once extended Fly - Upper section of an extension ladder. Sometimes known as Top Fly or Second Fly on ladders with more than one extension.

Parts of a Ladder Cont. Footpads - Rubber or neoprene foot plates, usually of the swivel type, attached to the butt of the ladder. Guides - Wood or metal strips on an extension ladder that guide the fly sections Halyard - Rope or cable used in hoisting and lowering fly sections

Parts of a Ladder Cont. Heat Sensor label - Label affixed to the inside of each beam to indicate if ladder has been exposed to extreme heat. (Test Required) Hooks - Curved metal devices installed on the tip end of ladders Mid Section - Also known as Intermediate, Middle, or First Fly. Middle section of a Triple Extension Ladder

Parts of a Ladder Cont. Protection Plates - Strips of metal attached to ladders at chafing points e.g. tips Pulley - Grooved wheel which the Halyard is drawn Rails - The two lengthwise members of a trussed ladder separated by truss blocks

Parts of a Ladder Cont. Rungs - Cross members that provide a foothold for climbing Stops - Wood or metal pieces that prevent fly sections from being extended too far Tie Rods - Support rods running from one beam to another

Parts of a Ladder Cont. Tip - Top of ladder Tormentor Poles - Staypoles for added leverage and stability on ladders feet. Truss Blocks - Separation pieces between rails of a trussed ladder

Types of Ladders Single/Wall Ladder - Consists of only one section from feet (2m - 10m) Roof Ladders - Single Ladder from feet (4m - 8m), with folding hooks to anchor over roof ridge Folding Ladders - Single ladders with hinged rungs and footpads to allow for attic or narrow space access. Normally feet (2.5 -5m)

Types of Ladders Cont. Extension Ladder - An adjustable length ladder with a Bed and one or more fly sections Combination Ladder - Multiple use ladder - step ladder, extension, and single Pompier Ladder (Scaling Ladder) - Used to climb from floor to floor via exterior windows on multi story buildings

Construction Beams and Rungs form the major components of a ladder. –Solid Beam and Truss Beam –Rungs 1¼ in diameter and spaced 14” apart

Construction Material Metal - Usually heat treated Aluminum alloy. –Advantages - Light weight, strong, allows for visual inspection, and easier to maintain –Disadvantages - Subject to extreme heat and cold, and conducts electricity.

Construction Material Cont. Wooden - Usually Douglas Fir beams. White Ash or Hickory for rungs –Advantages - Cost and reasonably light weight –Disadvantages - Heat and direct flame damage, shrinkage over time, cracks hidden if painted, and high maintenance

Construction Material Cont. Fiberglass - Usually a combination of Fiberglass beams and metal rungs –Advantages - Nonconductor of electricity and poor conductor of heat –Disadvantages - Weight, tends to chip and crack, and cost

Ladder Maintenance & Repair Maintenance means keeping ladders in a state of readiness Repair means to restore or replace that which has become inoperable.

Storage of Ladders (NFPA 1932) Keep ground ladders free from moisture Do not store or rest ladders where they are subject to exhaust or engine heat Do not store ladders where they are exposed to the elements Do not paint ladders except for the top and bottom 12 inches

Cleaning of Ladders (NFPA 1932) To be cleaned after every use to remove dirt and debris Use soft bristle brush and running water Tar, oil, and grease should be removed with safety solvents Wiped dry During cleaning look check for defects

Inspection & Service Testing (NFPA 1931) Inspected after each use and monthly Rungs - snug and no cracks, gouges, or deformation Bolts and Rivets - tight Welds - cracks and defects Beams - cracks, gouges, or deformation

Inspection & Service Testing (NFPA 1931) Heat sensor label - Any metal ladder subjected to direct flame or heat high enough to cause water to steam or boil, or change the colour of the heat sensor label, MUST BE TAKEN OUT OF SERVICE AND TESTED

Inspection & Service Testing (NFPA 1931) Wooden Ladders –Varnish not chafed, scraped, or darkened from heat –Dark streaks in wood means wood deterioration and must be removed from service

Inspection & Service Testing (NFPA 1931) Roof Ladders –Hook assembly operates smoothly –Check for rust, deformations and firmly attached

Inspection & Service Testing (NFPA 1931) Extension Ladders –Pawl assembly works. Hook and finger move freely –Halyard is not frayed or kinked –Pulleys turn freely –Fly sections move freely –Toggles move freely on stay poles

WARNING! Failure to remove a defective ladder from service can result in catastrophic ladder failure that may injure or kill fellow firefighters

Ladder Safety Do not overload ladder - approximately one firefighter every ft Always wear protective gear Choose proper ladder for job Lift with legs not back Use correct number of firefighters for raising and lowering

Ladder Safety Cont. Check for overhead electrical wires/hazards Set proper climbing angle (75° or 1ft out for every 4 high) Seat locks/pawls/dogs Secure properly before climbing (four point contact or tie off) Extend five rungs over roof

Ladder Safety Cont. Climber can stand upright and reach the rungs at arms length Tie off halyard before climbing Climb smoothly and rhythmically (Bear climb) Use leg lock or Class I harness Inspect after use

Selecting Ladders NFPA 1901 Pumper Ladder Requirements –1 extension ladder min 24 feet (8m) –1 roof ladder min 14 feet (4.3m) –1 folding ladder min 10 feet ( 3m)

Selecting Ladders Cont. First story roof ft ( m) Second story window ft ( m) Second story roof ft ( m) Third story window or roof ft ( ) Forth story roof - over 50 ft (15.2m)

Ladder Placement Extend five rungs above roof to provide footing and handhold when stepping on or off roof Place tip of ladder at top of window on leeward side when ventilating or suppression Place tip of ladder just below windowsill for rescue/access (may be extended into opening of a wide window)

Ladder Placement Cont. Avoid placing ladders over window and door openings Ladder two sides of building for safety Place at strongest part of building (corners) Place ladder tip over top of window when using smoke ejectors

Ladder Placement Cont. Avoid overhead obstructions such as overhangs, signs, trees, and wires Avoid uneven terrain or soft spots Avoid access and egress routes/paths Avoid placing ladders on surfaces/openings where fire is present or may reach Avoid unstable surfaces. E.g. elevator doors and manhole covers

Ground Ladders Carrying/Raising/Shifting/Climbing/Resc ue/Hoselines to be reviewed in practical sessions