KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN

Slides:



Advertisements
Similar presentations
Inspect Water Distribution EO Air Gaps, Vacuum Breaker, and Back Flow Preventers TP 8 50 min.
Advertisements

Typical Plumbing System
Assessed to ISO 9001 Certificate No. 1038Ha. SPECIFICATIONS FIRE HOSE REEL CABINET The wall opening for recessed cabinets should be of 1cm additional.
Generic Pressurized Water Reactor (PWR): Safety Systems Overview
Gas Meter Proximity to Electrical Equipment, Apparatus and Cables. To be applied by PNG Sales, Engineering and Installation operatives when locating 6m3/hr.
1 Lincolnshire Fire & Rescue Training Centre FIXED INSTALLATIONS FOAM INLETS COMPETENCE STATEMENT 375.
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN
Unit 206: Domestic hot water systems
1 Lincolnshire Fire & Rescue Training Centre FIXED INSTALLATIONS DRY AND WET RISERS COMPETENCE STATEMENT 373.
Walls Ron Gatepain constructionsite.
Watertube Boiler.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
BS9990 : 2015 Updates and/or Changes
Filling, purging and air removal
The DB In-Line Pumpout Unit Easy-to-use control panel with one switch to run the unit. 15 AMP reset fuse. 115 AC External water pump and tank drain have.
KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN
Fresh water system. Matter to be decided: Potable water Wash water Pressure in the system: usually 10 to 40 psi 69 to 275 kPa 0.69 to 2.75 bar.
CVFD Training – Water Supply SFFMA Training Objectives: –
Dennis Sabre Fire Appliances
Unit 205: Cold water systems
Unit 206: Domestic hot water systems
Purpose of Standpipe and Hose Systems
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
Intermediate SFFMA Objectives: – Hrs received.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
Mechanical for Oil Heat
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Assignment No. 1 [Grup 8] Figure below shows a portion of a hydraulic circuit. The pressure point B must be 200 psig when the volume flow rate is 60 gal/min.
“Design of Water Supply and Sewer Systems” IV. Water Tank (Service Reservoir). Dimensioning and Constructing (Drawing 4) Main Procedures 1. Determination.
DESIGNING FOR FIRE SAFETY PARTS 1,2,3 and 4
NFPA 54 National Fuel Gas Code Boiler Manufacturer ANSI Standards Local Codes Vent Manufacturer.
Instructor Lee Lautzenheiser
PLATFORM UTILITIES PAB 2073 Reference: PCSB/PMO document.
1 CTC 450 Review Water Quality Water Quality. 2 CTC 450 Water Distribution Systems Water Distribution Systems.
Urban Water Department of Hydro Sciences, Institute for Urban Water Management Peter Krebs Dresden, Global water aspects 1 Introduction to urban.
NGfL CYMRU GCaD PLUMBING APPLIANCES & COMPONENTS.
HE UTTAR PRADESH FIRE PREVENTION AND FIRE SAFETY RULES 2005
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
Job Performance Requirement Soft-Sleeve Hydrant Connection.
Firefighter III Module B Water Supply (4-19) (4-19)
PIPE LINE SYSTEM Series Pipe Line System Class I Class II Class III
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Ships Service Air System
ME444 ENGINEERING PIPING SYSTEM DESIGN
Unit 209: Drainage systems
Chapter 37: Fluid Containment
BOMBA BRIEFING QUESTIONAIRE FOR 30 AUGUST 2017
FIRE LIFT –DESIGN REQUIREMENTS in reference with NBC-2005
Plumbing system fundamental and design course
Properties and combustion of fuel oils
EXERCISES Two water reservoirs are connected by a pipe 610m of 0.3m diameter, f’=0.038 and the flow produced by the difference in water surface elevations.
Unit 37: Fluid containment Dr
Training for DVM air-conditioner
Unit 37: Fluid containment Dr
PLUMBING APPLIANCES & COMPONENTS
Private Fire Hydrant. Fire hydrant systems (also known as fire pumps, hydrant boosters, fire water pumps) are high pressure water pumps designed to increase.
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
FBE04 BUILDING CONSTRUCTION AND MATERIALS
February 2019.
Boiler Safety Valve Regulations
LIFT,ESCALATOR AND MOVING WALKS
Presentation transcript:

KURSUS PENGENALAN KEPADA PERKHIDMATAN MEKANIKAL DALAM BANGUNAN

WET AND DRY RISERS SYSTEM

AN INTRODUCTION TO FIRE FIGHTING DESIGN WET AND DRY RISER SYSTEM YATIM SELAMAT BIN LATIB JURUTERA MEKANIKAL

CONTENTS DRY RISER SYSTEM INTRODUCTION DESIGN STANDARDS LANDING VALVES BREECHING INLET RISER PIPE

DRY RISER SYSTEM Internal Hydrant for Firemen to use Topmost floor is higher than 19.3m (63f) and less than 30.5m (100f) Normally dry pipe and depend on the fire engine to pump water Comprises a riser pipe with landing valves at each floor which canvas hose with nozzle can be connected. Breeching inlets into which firemen pumps water provided at ground level.

DESIGN STANDARDS In the UBBL, the By-laws pertaining to Dry Risers are By-laws 230 and 232. The relevant standards are: 1. BS 5306 Part I (or equivalent Malaysian Std) 2. MS 1210 Part 2 (Landing Valves for Dry Risers) 3. MS 1210 Part 3 (Inlet Breeching for Riser) 4. MS 1210 Part 4 (Boxes for Landing Valves)

LANDING VALVES Landing Valves provided on each floor. Usually Located within fire access lobbies, protected staircases or protected lobbies. Installed not more than 0.75m(2.5 feet) above floor level. Boxes may be provided to protect Landing Valves. Fire Hose Canvas Type (38 mm) complete with 65 mm dia. quick coupling.

BREECHING INLET Installed at the bottom of the riser A two-way breeching inlet should be provided for a 100 mm diameter. A four-way breeching inlet for a 150 mm diameter. Breeching inlets located not more than 18m (59f) from the fire appliance access road. Breeching inlets located not more than 30m (100f) from the nearest external hydrant outlet.

DRY RISER PIPE Galvanised Iron (Heavy Gauge) or Class C tested to 21 Bars If the highest outlet is more than 22.875m (75 feet) the riser pipe diameter should be 150 mm. Normally the riser pipe diameter is 100 mm. Air release valve installed at the top of the riser to relief air trapped. Horizontal runs pipework should be sloped for proper draining after use.

DRAWING

CONTENTS WET RISER SYSTEM INTRODUCTION DESIGN STANDARDS LANDING VALVES BREECHING INLET RISER PIPE WET RISER PUMPS WET RISER TANKS PUMP STARTER PANELS AND CONTROLS

WET RISER SYSTEM Internal Hydrant for firemen to use. Always charged with water. Topmost floor is higher than 30.5m (100feet). Comprises Duty, Standby and Jockey pumps. Comprises 150 mm diameter riser pipe with Landing Valves at each floor. For high rise buildings each stage of wet riser should not exceed 70.15m (230 feet).

DESIGN STANDARDS In the UBBL, the By-laws pertaining to Wet Risers are By-laws 231, 232 and 248. The relevant standards are: 1. BS 5306 Part I (or equivalent Malaysian Std) 2. MS 1210 Part 2 (Landing Valves for Wet Risers) 3. MS 1210 Part 3 (Inlet Breeching for Riser) 4. MS 1210 Part 4 (Boxes for Landing Valves)

LANDING VALVES Landing Valves provided on each floor. Usually Located within fire access lobbies, protected staircases or protected lobbies. Installed not more than 0.75m(2.5 feet) above floor level. Boxes may be provided to protect Landing Valves. Fire Hose Canvas Type (38mm) complete with 65 mm dia. quick coupling. The pressure at Landing Valves not less 4 Bars but not more than 7 Bars.

BREECHING INLET Installed at the bottom of the riser. The firemen can pump water into the wat riser storage tank to make up for water used. A four-way breeching inlet for a 150 mm diameter. Breeching inlets located not more than 18m (59f) from the fire appliance access road. Breeching inlets located not more than 30m (100f) from the nearest external hydrant outlet.

WET RISER PIPE Galvanised Iron (Heavy Gauge) or Class C. The riser pipe diameter should be 150 mm. Should cover no more than 900m2 of floor area. Where more than one riser is required, the distance apart between not exceed 60m. The distance between lowest and topmost Landing Valves not exceed 70.15m. Air relief valves installed at the top to relief air trapped.

WET RISER PUMPS Duty, standby and Jockey pumps. The pump flow rate 1500 lit/min at running pressure not less than 4 Bars but not more than 7 Bars when any 3 Landing Valves are in use at the same time. Standby pump from Gen.Set or Diesel (fuel supply storage for 2 hr). Where more than one riser is required, the distance apart between not exceed 60m. The distance between lowest and topmost Landing Valves not exceed 70.15m. Air relief valves installed at the top to relief air trapped.

WET RISER TANKS Minimum capacity of 45,500 lit. with automatic refill rate of 455 l/min. The intermediate break tank for upper stages of the wet riser is 11,375 lit. with automatic make-up flow of 1365 l/min. Tanks material from pressed steel, fibre reinforced polyester (FRP) or concrete. The water tanks should be compartmented. Located on the ground floor, first or second basement. Usually separated from other water storage tank but it may be combined with hose reel tank.

PUMP STARTER PANEL AND CONTROLS Power supply cables to the panel should be of Mineral Insulated Copper Core (MICC). Wet riser pumps provided with 3 pressure switches: Starting and stopping the jockey pumpset Starting and stopping the duty pumpset Starting and stopping the standby pumpset

DRAWING

SIMPLE QUIZ WET RISER SYSTEM Which is the criteria below in the UBBL that ascertains that a wet riser system is required in a building? Topmost floor is higher than 18.3m Topmost floor is higher than 18.3m above the lowest basement level. Topmost floor is higher than 30.5m above the fire appliance level. Topmost floor is 18.3m above the fire appliance level. What is the wet riser pump design flowrate? 1000 lit/min 1250 lit/min 1500 lit/min 1750 lit/min What is the pump design pressure? 4 Bars at any Landing Valve 7 Bars at any Landing Valve Min. 4 Bars but not more than 7 Bars when any three Landing Valve use at the same time. 4 Bars but not more than 8 Bars.

SIMPLE QUIZ WET RISER SYSTEM What is the purpose of the Breeching inlet? To drain water from the system. To pump water into the wet riser during testing. For use by the firemen to pump water into the wet riser tank to make up for water used. For the firemen to use the water from the wet riser tank to supply for their fire engines What is the material of wet riser pipe? Galvanise Iron Class C Galvanised Iron Class B Copper pipe Stainless Steel What is the minimum fuel supply for diesel engine pump? Min. 1 hr continuos running Min. 2 hr continuos running Min. 3 hr continuos running. More than 3 hours but not more than 4 hrs.

SIMPLE QUIZ DRY RISER SYSTEM Which is the criteria below in the UBBL that ascertains that a dry riser system is required in a building? Topmost floor is higher than 19.3m Topmost floor is higher than 19.3m above the lowest basement level. Topmost floor is higher than 19.3m and less than 30.5m above the fire appliance level. Topmost floor is 30.5m above the fire appliance level. Where are usually Landing Valve located? At the wall At the staircases At the lobbies Fire access lobbies, protected staircases or other protected lobbies What type of Breeching inlet used for a 100 mm dry riser pipes? Two-Way Breeching inlet Three-Way Breeching inlet Four-Way Breeching inlet Two and Four-Way Breeching inlet

SIMPLE QUIZ DRY RISER SYSTEM What type of Breeching inlets used for 150mm dry riser pipes? Two-Way. Three-Way. Four-Way. Five-Way. What is the material of dry riser pipe? Galvanise Iron Class C Galvanised Iron Class B Copper pipe Stainless Steel Which of the following statement for the Breeching inlets are true? Breeching inlets located no more than 18m from the fire appliance access road and not more than 30m from the nearest external hydrant outlet. Located at 18m from hydrant. Located at 30m from Lift. Located at 35m above fire access.

SEKIAN TERIMA KASIH Yang Jauh berkirim Salam Yang dekat berpaut Rindu Akhir Kata… SELAMAT HARI RAYA MAAF ZAHIR & BATIN