© Emotron AB Protection against damage and downtime Emotron M20 Shaft Power Monitor.

Slides:



Advertisements
Similar presentations
SITOP select Automation and Drives SITOP select Electronic Diagnosis Module Fault diagnosis – rapid and reliable.
Advertisements

WP3 High Availability Drives Electrical Machines and Drives Research Group University of Sheffield Dr. Georges El Murr
© ABB Group September 1, 2014 | Slide Turbidity Systems Accurate, reliable turbidity measurement.
Daikin Altherma™ Troubling Shooting
Variable Frequency Drives VFD Basics
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
DRIVE THE WATER CYCLE January 10 TH DRIVE THE WATER CYCLE.
On Load Tap Changing Transformer Paralleling Simulation and Control.
High Power Hg Target Conceptual Design Review Hg Target System Controls V.B. Graves P.T. Spampinato T.A. Gabriel Oak Ridge National Laboratory February.
Copier Jam Detector Design Problem
Chapter 8 Output Modules.
One solution, many application Integrated Electronic Solution PowerSupply Flex.
Current Sensors. 2 Introduction Honeywell is proud to introduce its new line of current sensors and switches. - Current sensors and switches detect whether.
Conveyor Control using PLC, VFD, and Sensor
VECTOR DRIVES EASA June 2005 “REACHING NEW HEIGHTS” Dave Ruehle and Bill Colton.
1 Electronic Soft Starters How and Why they Work, and What they can do for You. Fairford North America.
SCADA and Telemetry Presented By:.
Sales Opportunities VersiStart i II. Ranges 23 Models 18A ~ 200A 7.5kW ~ 400VAC Voltage Ranges 200 ~ 440VAC 200 ~ 575VAC Protection IP20: 18 ~
Soft Start Sales Opportunities (IMS 2 ) ISSUE: ME00110A Soft Sales Opportunities IMS 2 Soft Starters.
SmoothnessAccuracy Improving Smoothness and Accuracy in Stepper Systems.
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
Alternating Current Circuits
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
Turbine Crane CRANES TURBINE NEA39. Turbine Crane PLANT STATUS! PV Daily Status Report.
Smart transmitters.
Sales Opportunities VersiStart i III. VersiStart i III Family.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
MonoDrive & XT Constant Pressure Controller
The complete flow monitoring solution Measure – Display – Switch – Transmit.
Page 1 LXMG , LXMG LXMG , LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Modules Training.
ELECTRO – PROPORTIONAL VALVES
3-Phase Submersible Motor Control
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Ionizer IZS31 Series. 1. Features (1) Following functions are added to the current IZS30 on sale. Detects the dirt on the electrode needle. Detects the.
CONTENTS: 1.Abstract. 2.Objective. 3.Block diagram. 4.Methodology. 5.Advantages and Disadvantages. 6.Applications. 7.Conclusion.
Name Of The College & Dept
1 Injection Moulding Energy-saving SHENZHEN INVT ELECTRIC CO.,LTD.
TRIGGER DELAY 100µs. G. Gräwer AB/BT/ECLBDS Trigger Delay2 The trigger delay is a back-up system that generates an asynchronous dump trigger for MKD and.
Esbe Rotary Motorized valves The ESBE Rotary Motorized valves (mixing valves and actuators) are used to control heating and cooling in buildings. We offer.
Page 1 LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Module Training Kit Rev 1.1 November 2006
The complete flow monitoring solution Measure – Display – Switch – Transmit.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
ARM and GPS Based Transformer monitoring system with area Identification Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
REDA Production Systems
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
Solar Pumps- High profitability and reliability lead to prosperity.
Elements of Electrical Design HASMUKH GOSWAMI COLLEGE OF ENGINEERING
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
Altivar Process Unique Value Propositions. Drives vision Extend drives sales from Transactional to Solutions & Segments Best in Class Products Solutions.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
MEDIUM VOLTAGE APPLICATIONS.
CLOSED-LOOP MOTOR SPEED SENSOR & CONTROLLER
Asahi/America Electric Actuators Series 94.
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
HIGH PERFORMANCE PRESSURE SYSTEMS.
Motor Drive Prof. Ali Keyhani. Modern Variable Speed System A modern variable speed system has four components: 1. Electric Motor 2. Power Converter -
The Novel Fuel Combustion Engine with Dry Run Protection
Protecting you from the worst electrical problems
Robicon Perfect Harmony.
Cashew Dryer User Manual
Student’s Name with USN No.
MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric.
Asahi/America Electric Actuators Series 94.
Copier Jam Detector Design Problem
Universal Dim Actuator UD/S
PLC Front Panel.
easYgen-3000XT Series Training
Presentation transcript:

© Emotron AB Protection against damage and downtime Emotron M20 Shaft Power Monitor

© Emotron AB Unique shaft power calculation Uses motor as a sensor Increased reliability Reduced maintenance costs Low-cost installation Emotron M20 – efficient protection

© Emotron AB Preventive action saves money Efficient and reliable operation Reduced maintenance costs Short pay-back time Early warning or stop Pump is running dry Scraper blade is damaged Crusher is jammed Load Time Overload stop Overload warning Normal load curve Underload warning Underload stop

© Emotron AB Unique shaft power monitoring Unique monitoring technique Shaft power = Input power – Power loss Accurate value over the whole load range More reliable supervision Shaft power Current Phase angle Input power kW/A/φ° Motor load 100%

© Emotron AB Uses motor as a sensor Uses drive motor as a sensor No sensors or extra cabling No holes in pipes Increased reliability Reduced installation costs Reduced maintenance

© Emotron AB Direct correlation to pump curve Prevents dry-running and cavitation Direct correlation to pump curve Set max. and min. load levels for pump and motor Immediately detects over- or underload Head (mvp) Warning dry-running Warning cavitation Operational area Pump Motor shaft power Operational area Load Flow

© Emotron AB Higher accuracy with scalable signal Unique scalable analogue output signal Machine load scaled to actual working range Reliable monitoring also when small load variations Input to indicating instruments, controllers, PLC Machine load 100% Output signal mA 70% Actual working range 30% Emotron M20 scaled output signal Unscaled output signal

© Emotron AB Low-cost installation Reduced installation costs Uses motor as a sensor No external sensors No holes in pipes Monitors via current transformer No external transmitters Minimized wiring

© Emotron AB Enter your settings in three seconds Unique Auto set feature Set four protection points in three seconds Press Auto set during normal operation Warning and stop levels calculated automatically

© Emotron AB Zero maintenance Higher reliability and reduced maintenance Replaces costly and service- demanding components Solid-state device with no moving parts Installed away from hostile operating area

© Emotron AB Protection to meet your needs

© Emotron AB Pumps Warns or stops the pump Risk of dry-running or cavitation Motor does not drive the pump Low flow, closed valve, blocked pipe etc. Reduced maintenance costs Increased reliability Less downtime

© Emotron AB Mixers Warns or stops the mixer Damaged mixer blade Shaft oscillation Viscosity is right Reduced maintenance costs Increased reliability Less downtime

© Emotron AB Scrapers Warns or stops the scrapers Jamming Damaged scraper blade Reduced maintenance costs Increased reliability Less downtime

© Emotron AB Crushers, conveyor systems etc. Warns or stops the process Jamming occurs Material runs out Reduced maintenance costs Increased reliability Less downtime

© Emotron AB Technical data Emotron M20 Supply voltage / / VAC Frequency50 / 60 Hz Rated currentUp to 999 A via current transformer Protection classIP20 ApprovalsCU, UL, cUL

© Emotron AB A dedicated product portfolio Emotron Shaft Power Monitors Emotron Softstarters Emotron Variable Speed Drives PROTECT START PROTECT STOP START PROTECT CONTROL STOP