What is Energy Monitoring?. Market Direction The lighting control industry being driven to manage energy holistically and to show ROI – Energy costs are.

Slides:



Advertisements
Similar presentations
Lighting concepts – Ballasts and Lighting Controls
Advertisements

NEMA. 2 Utility Metering vs. Submetering 10/11/2014 New PowerPoint Template Utility Meter Meter provided by utility with the purpose of measuring.
Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
Webinar May 19, What? Why? How? What is a utility bill clean-up? Why is it important? How can it help you? What’s next?
Lineage Power - Total Efficiency TM Smart Grid A Telecom / Commercial consumer’s perspective Paul Smith – Technical Marketing Manager, Lineage Power
Integrates systems that typically operate in silos, so they work together as a single system Adds a layer of intelligence to turn an integrated building.
Variable Frequency Drives VFD Basics
ANALYTICS: BRINGING VALUE TO THE UTILITIES IN MITIGATING ENERGY LOSSES José-Manuel LOPEZ Istanbul, May 9, 2014.
Gemini: A Non-Invasive, Energy-Harvesting True Power Meter
The Bottom Line In Energy Cost Reduction Energy Automation Systems, Inc. EASI.
E-Mon Energy™ Energy Monitoring Software
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
© 2007 Control4. Smart System Controller HC-300 – Linux-based central brain for the home Monitors and manages energy use of the smart home – Lighting.
Simple, accurate tenant sub-metering
1. 2 Jamie Caplan Square D by Schneider Electric Energy Solutions – Northwest Tel:
Efficient flexibility in room management with SAUTER EY-modulo.
State Incentives for Energy Efficiency Commercial and Industrial New Jersey Board of Public Utilities Office of Clean Energy Mona L. Mosser Bureau of Energy.
Watt Smart Wireless Single Phase Power Monitoring System (WPMS) Kamyar G. Osgoei Glen Nogayev Titus Cheund Wenqi Sun Babak Sobhani.
GE Consumer & Industrial Multilin PMCS Energy Management Systems Vincent Thomas.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
Solutions for Meter Data Management Layne Nelson Product Manager LODESTAR Corporation Copyright © 2005 LODESTAR Corporation - All Rights Reserved LODESTAR.
Getting Green Building Automation. Why is Building Automation a Green Technology? There are programs starting all over the nation that focus on alternative.
Solutions Overview SAVE FROM 10 – 50%
Today’s Enterprise Energy Management Systems: What to look for…. Mark A. Noyes CEO and President Cambridge, Massachusetts.
PowerLogic® E5600 power and energy meter 1.
Total Energy Usage As A Measure of Building Performance 30% Building Energy Savings Through an Energy Lifecycle Approach to Building Construction, Retro-fitting,
Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900E PUBLIC INFORMATION L19 - Combining the Latest Rockwell Automation® Hardware.
0 Invensys Energy Management Division ZigBee. 1 Invensys Proprietary Data Energy Management Overview The Basics: Solutions and products that help customers.
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
Smart Buildings Srirangarajan Kadaba National Manager – Energy Edge Buildings Business Schneider Electric 21June 2010.
Company Profile ► Our Expertise Here at SIEMSTECH we have a passion for designing and implementing integrated, network-centric technology solutions across.
1 Sales Academy Training Inner Range Product Advantages, Competitors & The Future.
THIN CLIENT COMPUTING USING ANDROID CLIENT for XYZ School.
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
© 2009 IBM Corporation Let’s Build a Smarter Planet Thongchai Watanasoponwong – Country Manager Power Systems, STG September 15 th, 2009 Green IT เทคโนโลยีสีเขียวเพื่อสิ่งแวดล้อม.
Non-Res Lighting Subcommittee Retrofit Lighting Standard Protocol Review 04/03/14.
Powered by M2m methodology diagram Anything Anywhere Our specialist expertise and partnerships have enabled us to tailor smart monitoring solutions and.
Intelligent Building Systems a Key to Sustainability Paul Ehrlich, PE President Building Intelligence Group EPRI Summer Seminar 2008 San Francisco, CA.
IntelliSense.io Beyond the hype - Real World Applications / Solutions of Internet of Things.
Advanced Controls and Sensors David G. Hansen. Advanced Controls and Sensors Planning Process.
Tier 2 Power Supply Planning Workshop Advanced AMI Benefits Overview.
Consumer Education Challenge 1000 kwh x rate/kwh = $ Billed Amount When asked about energy usage, the customer receives this…… But really understands this…………
We hear much about energy problems; supply shortages, pollution issues and high prices, but the solutions to these problems are here now in the form of.
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
3/12/2013Computer Engg, IIT(BHU)1 CLOUD COMPUTING-1.
BLUEPILLAR.COM /COMPANY/BLUE-PILLAR /BLUEPILLARINC CONFIDENTIAL & PROPRIETARY Unique solutions to connect and control legacy energy equipment for the purpose.
Our Solution 1 Automated Energy’s Prophet Load Profiler™ allows our Utility Partners and their C & I customers to harness the value of consumption data.
FP7/ GA n° URB-Grade Decision Support Tool: Towards the District as a Service Impact Workshop, Brussels Mikel Larrañaga, IK4-Tekniker April.
1 1 DISTRIBUTION EFFICIENCY INITIATIVE (DEI) Benefits on Both Sides of the Meter RTF MEETING February 5, 2008.
2 © 2014 Eaton. All Rights Reserved.. 2 Intelligent Energy Management Systems Provides powerful insight into facility energy usage that yields dividends:
Metering and Monitoring  The Business Case.  Implementing the project.  Benefits – accurate data and data analysis.  On-going challenges.
Sustainability Center Data Collection
System Network Structure
A new step to reduce computers giving negative Impacts to the earth
Portable Working Standard
Greening Your Information Systems
FMANZ SUMMIT % OF YOUR CURRENT ENERGY USE IS PROBABLY WASTE
Programmable Logic Controllers (PLCs) An Overview.
Sustainability Left click to advance $200 Billion
H.O.M.E. Home Organization and Monitoring of Energy
Solution: IDSM for SMB and MDU Markets

Catalyst Pitchback Energy Efficiency as a Service
[PLACEHOLDER FOR DISTRIBUTOR LOGO]
How to tackle air pollution
PowerLogic ION6200 Power and energy meter.
Light level sensor Temperature sensor Motion detection ecDeskSensor
Simple, accurate tenant sub-metering
Power monitoring software
Presentation transcript:

What is Energy Monitoring?

Market Direction The lighting control industry being driven to manage energy holistically and to show ROI – Energy costs are going to go up – Changing regulations are impacting local building codes – Clean energy is expensive and unreliable for the supply side – Being green is not just a marketing strategy, it’s a necessity to be efficient and reduce operating expenses

What do you need? Products that can actually help lower operating costs Products help owners and facility managers prove that they’re doing the right thing Transition from simply monitoring energy usage to management of energy

Energy Monitoring Hardware and software that connects to your energy resources to provide a defined baseline of energy consumption Knowing is the start – you need to see what your energy usage is as a starting point

Energy Monitoring Technologies

Calculated - Good If we know that a load is 50W and it’s at 50%, can’t we just assume it’s using 25W? – Not really… – We can get fairly close with load profiling, but the wattage numbers don’t scale linearly – Commercially, ballasts are very difficult to accurately profile – The numbers produced by these guesses can be off by 20% Really only works for lighting, not all loads

Current Monitoring - Better Assume that the voltage is stable and measure the actual current – P=I*V – Can provide fairly accurate results for stable voltages – Has a problem with active loads, like ballasts Power factor correction helps in the “on” state “Off” state will read much higher than actual power due to phase shifts – Can expect a 10% error in measurements Can be used for non-lighting loads

Power Metering - Best Samples real voltage and real current at high frequencies Compensates for phase offsets Doesn’t get fooled by voltage drops or non-linear current scaling Expensive Errors can be smaller than 1% Useful for measuring ANY electrical load

Crestron Solution Whatever your level of energy sustainability, we can help make an impact We have calculated, current monitoring and power metering solutions to help you grow and evolve your level of energy management

Crestron Calculated Solutions Supported by every Crestron processor No special products required – Lowest hardware cost – Great initial solution for starter retrofit applications Works perfectly with Crestron’s range of wired and wireless dimmers and switches, including 120/240/277V

Crestron Current Monitoring Crestron products include optional “PM” version to deliver current monitoring data – Green Light® Power Pack – Green Light® Integrated Lighting System – Green Light® DALI Ballasts

Crestron Energy Monitoring Solution GLS-EM-MCU: Metering Control Unit Ethernet based Main Panel Feed Monitoring and/or Branch Monitoring Power metering across 3 phases (main legs) Reports data to control system and Fusion EM Monitors & logs Voltage, Current, & Active Power Monitors up to 84 individual branch circuits (With GLS-EM-CTI) Installs next to an electrical panel Operable with V, split and 3 phase systems Non-volatile memory reliability stores internally logged data

GLS-EM-MCU – Parts and Pieces GLS-EM-MCU: Mains monitor GLS-EM-CTI-*: Branch monitors GLS-CT-*: Current transformers – These come in standard and high accuracy models – HA might allow us to claim revenue grade metering

GLS-EM-MCU Main monitor Need one per panel Monitors three main feeds and four pulse inputs Can support four branch monitors – Up to 84 branches VAC (Yes, 347!)

GLS-EM-CTI Branch monitors – Comes in 6, 15 and 21 branch options – Specific for two and three phase systems Connects to the GLS-EM-MCU via a 7-wire bus – Also has a pass-through for next GLS-EM-CTI unit Reports through the GLS-EM-MCU

GLS-CT Current transformers – every monitored leg needs one Comes in multiple varieties: – 20A – 50A – 200A – 400A – 600A – High Accuracy/Standard Accuracy High accuracy version has factory calibration to remove small errors due to manufacturing differences – Improves error from 5% to <1% (May allow us to claim revenue grade – still investigating)

Available Information Real Time Information - Power – Voltage – Active Power – Pulse Rate Historical Information – Energy – Voltage – Current – Active Power – Energy – Pulse Usage – Power Factor – Energy Meter (aggregated) – Pule Meter (aggregated)

Pulse Metering Allows for inclusion of 3 rd party metering devices Keeps precise count of pulse rate and pulse count Typically used for water or natural gas

Odds and Ends Often, for larger buildings, the main feed is much larger than 600A. How does this get monitored? – For these large installations the feed is typically broken up into multiple, parallel, 600A (or less) feeds – Our tools allow us to clamp one CT onto one parallel feed and instruct the monitor to compensate for the fact that multiple feeds are in use (Basic multiplication)

Energy Monitoring Technologies - Recap Three monitoring technologies – Guessed/Estimated Supported by all Crestron products Not as accurate – Current Measurement Only Supported by Crestron PM option products Mid-level accuracy – Power Measurement Measured by a dedicated device: GLS-EM-MCU Most accurate option for measurement

Bringing It All Together All of these work well independently The real power is harnessed when you bring these technologies together into a overarching energy management strategy

The Next Step… Energy Management

Making the Transition from Monitoring to Management Using the data gathered from the energy monitoring hardware and software, the facility manager realizes there’s an opportunity for savings Now that there are metrics, the goal is to make the numbers move – We do this via our control products and Fusion™

Metering your energy consumption and collecting the data by using an energy monitoring software Uncover places to save energy - such as making upgrades or replacing inefficient equipment Putting into place energy saving functions – such as demand response settings or eliminating wasted energy in unoccupied spaces Tracking progress by analyzing the real-time data and comparing with historical information to what these efforts are actually achieving What are the steps involved?

6-Part Panel-Based Energy Management System: 1.Electrical Panel 2.Current Transformers (GLS-EM-CT) 3.Current Transformer Interface (GLS-EM-CTI) 4.Meter Control Unit (GLS-EM-MCU) 5. Control Processor (MC3) 6.Analysis Software (Fusion) Crestron Energy Management

Seamless integration of lighting, shades, HVAC, security, IT, and AV with existing building management systems and other devices – no other gateway needed Direct connection over BACnet/IP through Crestron 3 Series Control Processors Works with BACnet/IP, LonWorks, Modbus, KNX and others Crestron Building Management System Gateway

Bringing it all together: Monitor, Manage AND Control The Crestron solution for the management of information and resources within the building to reduce energy consumption, save time and money is Fusion EM™ Fusion EM is the tool that allows you to Monitor, Manage and Control your entire operation

Bringing it all together: Monitor, Manage AND Control Monitor: See all energy resources including data analysis from your energy monitoring devices. Compare historical vs. real-time energy usage Manage: Use the software to implement change and automate functions and schedule events such as: – Temperature and lighting level set points – Demand response settings – Global lighting and climate control for unoccupied spaces Control: Anticipate needs based on the occupants and usage. By using Fusion for predictive management of the facility you can ensure they are being utilized efficiently

Thank you! Want more information? Call us at or visit crestron.com