CVP AND FLUID RESPONSIVENESS JAMES RUDGE SIMON LAING.

Slides:



Advertisements
Similar presentations
REGULATION OF BLOOD PRESSURE
Advertisements

Ventricular Pressure-Volume Loops
Dr Bronwyn Avard, July 2010  To understand the basic physiology of shock  To understand the pharmacodynamics and pharmacokinetics of vasoactive drugs.
Hemodynamic Monitoring
The New Surviving Sepsis Bundles: From Time Zero to Tomorrow
Cardiac Output: And Influencing Factors. Cardiac Output Amount of blood pumped out by each ventricle in 1 min CO = HR x SV.
Cardiovascular II.
 By the end of this lecture the students are expected to:  Define cardiac output, stroke volume, end- diastolic and end-systolic volumes.  Define physiological.
Haemodynamic Monitoring
A Randomized Trial of Protocol-Based Care for Early Septic Shock Andrea Caballero, MD January 15, 2015 LSU Journal Club The ProCESS Investigators. N Engl.
Pablo M. Bedano M.D. Community Regional Cancer Care.
PVI Overview Physiology Fluid administration challenges PVI method
Severe Sepsis Initial recognition and resuscitation
FROM CEM SEPSIS TOOLKIT PAPERS TO COVER NGUYEN EARLY LACTATE CLEARANCE IS ASSOCIATED WITH IMPROVED OUTCOME IN SEVERE SEPSIS AND SEPTIC SHOCK P Single.
A REVIEW OF FUNCTIONAL HAEMODYNAMIC MONITORING AJ van den Berg.
Cardiovascular system in its context Reverend Dr. David C.M. Taylor School of Medical Education
Set your intravascular volume right Jost Mullenheim James Cook University Hospital, Middlesbrough.
Regulation and Integration
Objectives Discuss the principles of monitoring the respiratory system
MODULE F – HEMODYNAMIC MONITORING. Topics to be Covered Cardiac Output Determinants of Stroke Volume Hemodynamic Measurements Pulmonary Artery Catheterization.
Introduction to Cardiac Cycle and Cardiac Output
Hemodynamic Monitoring By Nancy Jenkins RN,MSN. What is Hemodynamic Monitoring? It is measuring the pressures in the heart.
CONCEPTS OF NORMAL HEMODYNAMICS AND SHOCK
CARDIAC AND VASCULAR FUNCTION CURVES.. Figure Length-force relationships in intact heart: a Frank-Starling curve Optimal Length.
Prof. Jean-Louis TEBOUL Medical ICU Bicetre hospital University Paris XI France What is the best way to assess What is the best way to assess fluid responsiveness.
 By the end of this lecture the students are expected to:  Understand the concept of preload and afterload.  Determine factors affecting the end-diastolic.
Venous Function. Function of the venous system Function of the venous system Definitions Definitions Mean circulatory filling pressure Mean circulatory.
Monitoring Fluid Responsiveness Murat Sungur, MD Erciyes University Medical School Department of Medicine Division of Critical Care Medicine.
Blood Pressure Clinical Science Applied to Nursing CopyrightCSAN2005CardiffUniversity.
Frank-Starling Mechanism
Hemodynamic optimization in intra- abdominal hypertension Jan J. De Waele MD PhD Surgical ICU Ghent University Hospital Ghent, Belgium.
Inferior/Right Ventricular Infarction CLINICAL PRESENTATION AND TREATMENT Lady Minto Hospital Emergency Rounds February 2015 Prepared by Shane Barclay.
Prof. Jean-Louis TEBOUL Medical ICU Bicetre hospital University Paris-South France Optimal blood pressure target in septic shock.
Do you want a Fluid Bolus?. Why give fluid – The theory? Increase preload, increase cardiac output, increase oxygen delivery.
A Comparison of Albumin and Saline for Fluid Resuscitation in the Intensive Care Unit The SAFE Study Investigators N Engl J Med 2004: 350:
How and when should we monitor CO and SV in shock? When would I want to measure CO or SV in shock ? Alexandre Mebazaa, MD, PhD University Paris 7 Anesthesiology.
ITU Journal Club: Dr. Clinton Jones. ST4 Anaesthetics.
Cardiac Output. Cardiac output The volume of blood pumped by either ventricle in one minute The output of the two ventricles are equal over a period of.
Cardiac Physiology – Control of Cardiac Output
Cardiovascular Physiology
Copyright © 2008 Thomson Delmar Learning CHAPTER 15 Hemodynamic Measurements.
Prof. Jean-Louis TEBOUL Medical ICU Bicetre hospital University Paris South France Challenge in Right Heart Failure.
1 Dr. abbas Foroutan Cardiac Mechanics Heart Physiology Heart as a pump Oct.2005 By: Dr. Abbas Foroutan Shaheed Beheshti Univ. Med. Sci.
Blood Pressure Clinical Science Applied to Nursing CopyrightCSAN2005CardiffUniversity.
Early goal directed therapy in the treatment of sepsis Nouf Y.Akeel General surgery demonstrator Saudi board trainee R3.
Blood Pressure Normal BP varies by age, but is approximately 120 mm Hg systolic over 80 mmHg diastolic in a healthy young adult ( in females, the pressures.
Determinants of Cardiac Output and Principles of Oxygen Delivery
Physiology of Ventricular Function Dr. Chris Glover Interventional Cardiology Director of Education University of Ottawa Heart Institute January 12, 2015.
Haemodynamic Monitoring Theory and Practice. 2 Haemodynamic Monitoring A.Physiological Background B.Monitoring C.Optimising the Cardiac Output D.Measuring.
11 November 2009 Cardiovascular Physiology Lab this Week: Human EKGs, Heart Sounds, and Blood Pressure… Wear running shoes, comfortable clothes, bring.
United States Statistics on Sepsis
Hemodynamic Monitoring John Nation RN, MSN Thanks to Nancy Jenkins.
REGULATION OF BLOOD PRESSURE. MABP = CO x TPR Mean Arterial Blood Pressure.
© 2015 Pearson Education, Inc. Figure Pressure and Volume Relationships in the Cardiac Cycle. Aorta Electro- cardiogram (ECG) QRS complex P T ONE.
Acute Respiratory Distress Syndrome
Functional Hemodynamic Monitoring NEANA Spring Meeting April 2016 Donna Adkisson, R.N., M.S.N. Clinical Educator LiDCO, Limited.
Cardiovascular System
Update in Critical Care Medicine Ann Intern Med 2007;147:
Elsevier Inc. items and derived items © 2010 by Saunders, an imprint of Elsevier Inc.1 Review of Hemodynamics Elsevier Inc. items and derived items © 2010.
 Search Engines › CINAHL, PubMED, and Google Scholar  Search Words › Sepsis, Shock, CVP, Fluid Management, Efficacy, Alternatives, etc.  Results.
Cardiac Output And Hemodynamic Measurements
Cardiac Physiology Class 1.
高風險手術患者麻醉中的血液動力學分析 Hemodynamic optimization for high risk surgical patients 三軍總醫院麻醉部 呂忠和醫師.
بعض مؤشرات القلب والدورة الدموية : معدل النبض ( ضربات القلب )
Fluid responsiveness: an evolution of our understanding
Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation 
Inferior/Right Ventricular Infarction
Predicting cardiac output responses to passive leg raising by a PEEP-induced increase in central venous pressure, in cardiac surgery patients  B.F. Geerts,
Non-invasive assessment of fluid responsiveness using CNAP™ technology is interchangeable with invasive arterial measurements during major open abdominal.
Presentation transcript:

CVP AND FLUID RESPONSIVENESS JAMES RUDGE SIMON LAING

CVP Where measured Usually measured in the SVC and represents the filling pressure of the right atrium Theory CVP should reflect R sided filling pressure Increasing this > greater SV &CO > increased MAP Cardiac output = stroke volume x heart rate MABP = cardiac output x total peripheral resistance

VODCAST SLIDE PRELOAD STROKE VOLUME FRANK-STARLING MECHANISM STROKE VOLUME FORCE-TENSION MECHANISM AFTERLOAD 1.Increased contractility (inotropy) 2.Decreased afterload 1.Increased contractility 2.Increased preload

WHY RELEVANT Fluid resuscitation remains the treatment for shock, hypoperfusion and hypotension BUT – if fluid does not increase SV, it serves no benefit and may be harmful Part of EGDT (? debunked by process and arise) Surviving Sepsis Campaign: after 30ml/kg fluid challenge CVP should be maintained >8mmHg for non-ventilated patients 12-15mmHg for MV patients (to overcome PEEP) Achieved by repeated fluid challenge in addition to maintenance fluids

THE PAPER Marik, Paul E., and Rodrigo Cavallazzi. "Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense*." Critical care medicine 41.7 (2013):

PAPER Meta-analysis of 43 studies involving adult humans fluid responsiveness maneuvers 1802 patients in total Studies were largely in ventilated patients: 22 in ICU patients: 4 cardiac surgery patients 20 in operating room patients: 13 cardiac surgery patients 1 healthy volunteer study

PAPER A meta-analysis reviewing all relevant clinical trials that investigated the ability of CVP to predict fluid responsiveness defined as an increase in CO or SV following a preload challenge, usually a volume challenge or passive leg raising (PLR) maneuver. Study selection: Only those reporting the correlation coeeficient or AUC between CVP and CO following either PLR, fluid challenge, or PEEP challenge

THE PAPER Mean CVP Responders: 8.2 (+/- 2.3) Non-responders:9.5 (+/- 2.2) Summary AUC: 33 studies Overall:0.56 (95% CI ) Summary Correlation coefficient between baseline CVP and delta SVI/CI 20 studies Overall:0.18 (95% CI, 0.1–0.25) 50:50 chance of CVP predicting fluid responsiveness – toss a coin Either very low, or low correlation

AUC ROC CURVES Good explanation: SPECIFICITY SENSITIVITY In a perfect test: Begin at 0, ascend vertically to upper left corner, traverse vertically to upper right corner I.e. 100% sensitive and 100% specific The AUC would be 100% or 1.0 A diagonal line from point 0 to upper right corner would have AUC of 50%, or 0.5 This is no better than tossing a coin, 50:50 AUC = 0.5 AUC = 1

AUC ROC CURVES Sensitivity = true positives Specificity = True negatives As the sensitivity of a test goes up, the specificity usually goes down In the example below, the lower the cutoff for cancer, the higher the percentage of identified cancers (sensitivity) This means more false positives occur, lowering specificity We accept a this because it is better to have more cancer scares than more cancer misses

CORRELATION COEFFICIENTS PERFECT POSITIVE CORRELATION (R) = 1 PERFECT NEGATIVE CORRELATION (R) = -1 No correlation (r) = 0 Correlation = strength of association between variables Does not inform about cause and effect

CORRELATION COEFFICIENTS r values: = very low, probably meaningless = low, consider further investigation = reasonable correlation = high correlation = very high, ?bias/errors