Producer of toroidal components marked NT Magnetics s.r.o.

Slides:



Advertisements
Similar presentations
Shunt Capacitor Switching For Power Factor Improvement Clayton H Reid.
Advertisements

Insert your subtitle here. Who we are Suarcom Luoyang Electronics Co., Ltd , was established in 2004 SUARCOM LUOYANG belongs to ZAREL, a Spanish industrial.
Chapter 12 Transformers. Chapter 12 Transformers.
Presentation : IMS – Tech Managers ConferenceAuthor : IMS StaffCreation date : 08 March 2012Classification : D3Conservation :Page : ‹#› 07 - TransformersAuthor.
G.E. UPS Productline.
Transforming Ideas Into OEM Products For Over 50 Years! mc i TM MCI Transformer Corporation
Chapter 12 Electromagnetic Induction Permission granted to reproduce for educational use only. © Goodheart-Willcox Co., Inc. Objectives  Demonstrate.
Instrumentation: ground and noise Temperature Measurement.
TRANSFORMERS. TRANSFORMER PARAMETERS Turns Ratio (n) It is defined as the ratio of the number of turns in the secondary winding (N sec ) to the number.
Problem #2-8 A 480 – 120 V, 60 Hz transformer has its high voltage winding connected to a 460 V system, and its low voltage winding connected to a 24/32.8°Ω.
Problem # 2-3/4 A core-type transformer rated at 37.5 kVA, 2400 – 480 V, and 60 Hz has a core whose mean length is 1.07 m and whose cross-sectional area.
Copyright  2003 McGraw-Hill Australia Pty Ltd PPTs t/a Electrical Principals for the Electrical Trades 5e by Jenneson Slides prepared by Anne McLean Figure.
1 Position Paper on IEEE Task Force on Insulator Icing Test Methods Item # 5 Power Supply Requirements By Rudi F. Kremer Vice President.
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
Unit 29 Three-Phase Transformers. Objectives: Discuss the construction of three-phase transformers. Discuss the formation of a three-phase transformer.
Copper Development Association K Rating of Transformers supplying Harmonic Rich Loads
Single Phase IEC and EATS Distribution Transformers
Unit 28 Single-Phase Transformers. Objectives: Discuss the different types of transformers. List transformer symbols and formulas. Discuss polarity markings.
CHAPTER 6: TRANSFORMER BAKISS HIYANA ABU BAKAR
Chapter 2 Transformers.
Unit 27 Transformers. Objectives –After completing this chapter, the student should be able to: Describe how a transformer operates. Explain how transformers.
FOWLER CHAPTER 12 LECTURE 12 TRANSFORMERS. TRANSFORMERS CHAPTER 12 TRANSFORMERS ARE MULTIPLE WINDING INDUCTORS. WORK ON THE PRINCIPLE OF MUTUAL INDUCTANCE.
BENE 1113 PRINCIPLES OF ELECTRICAL AND ELECTRONICS
POWER CIRCUIT & ELECTROMAGNETICS
Arkadiusz Rymanowski Commercial Director.
Elec467 Power Machines & Transformers
V s N s V p N p = 1. What is mutual induction, how does it work? 2. What is self induction, how does it work? 3. What is the significance of the turns.
Inductance and Inductive Reactance Inductance - the characteristic of an electrical ckt that oppose any change in current Symbol is “L” measured in a Henry.
Modeling of Power Transformers A Static Device. Transformers The transformer enables us to utilize different voltage levels across the system for the.
1 The Transformer 1. 2 X XX X X B field into page L L No voltage on terminals.
Lecture 11Electro Mechanical System1 Delta-Delta Connection  Three single-phase transformers connected delta-delta  H 1 terminal of each transformer.
SURENESS EFFECIENCY WILLINGNESS FOCUS ON THE FUTURE.
Electromagnetism Presented by: BSIT07-46 Presented to: Department of Computer Science Bahuddin Zakariya University Multan, Pakistan.
Suggestion on How to Use
CONTENS 1. Production Capacity 2. Production Range
KATKO/JH/03/2000/1 Company Profile l Our products are globally marketed l Our products are quality and price competitive.
Presentation 2012 GTW BEARINGS s.r.o.1.  History  Location  Technical Specialization  Products ◦ Components ◦ Bearing Systems  Bearings Technology.
A company in growth Date: The group Locations Structure Quellmalz GmbH Near Chemnitz, Germany Injection Moulding, Insert Moulding, Painting,
SMJE 2103 Electrical Power System
SMJE 2103 Electrical Power System 3- Ph Power Apparatus.
ELECTRICAL MACHINES TOPIC: SINGLE PHASE TRANSFORMER Transformer1 ELECTRONICS AND COMMUNICATION.
EEK260 -Electrical Machines By Dr. Mohamad Kamarol Mohd Jamil Room: 2.32 Ext: 6064.
True-False Questions. A magnetic core material may exhibit hysteresis or saturation but not both.
Inside Sales Customer Service Product Training 11/18/2008.
1. 2 Magnetization Current in a Real transformer Although the output of the transformer is open circuit, there will still be current flow in the primary.
Automation and Drives A&D SD Customer Service & Support A&D SD CST 23/11/04 1 of 14 10A MotorTheory.ppt Motor Theory Motor Construction Motor Theory Drives.
Electronics Technology Fundamentals Chapter 10 Inductors.
Auto Transformer Current Flow. Principles of Auto Transformers H X H0/X0.
HNC/D Engineering Science
True-False Questions.
Chapter 18 Transformers.
Topic presentation Name, function
ELEC 3105 Basic E&M and Power Engineering
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Transformer -Types & Applications
ELE 2103 Dept . of E & E, MIT Manipal
POWER SUPPLIES EQUIPMENT AND SYSTEMS
Protecting you from the worst electrical problems
Protecting you from the worst electrical problems
Elecsys Mfg.Corp.is a Philippine Economic Zone
MAGNETISM AND ITS USES Producing Electric Current
Single Phase Transformers ELE 2103 Electrical Machinery1
Transformer Factory (Cast Resin)
Overcurrent Protection— Fuses and Circuit Breakers
Class Project Phase 1 (Objective 1 and 2)
Protecting you from the worst electrical problems
Protecting you from the worst electrical problems
Electrical Machines (EELE 3351)
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Producer of toroidal components marked NT Magnetics s.r.o.

Producer of toroidal components marked NT Magnetics – member of TALEMA GROUP Profile of TALEMA GROUP Founded in 1975 in Munich, Germany Specialized in production of toroidal components Over 600 employees in Europa and Asia Two production plants: - NT Magnetics – Czech republic (Plzen, Chebska 27) - TALEMA India - India 90% of all production is custom made Talema Group is one of the biggest manufacturer of toroidal components in Europe and Asia

NT Magnetics - Czech Republic sales design marketing – East Europe production Facility quality control Talema Holdings Talema Germany sales design marketing Talema India production facility Nuvotem Ireland Administrative Center sales design material Purchasing marketing Producer of toroidal components marked Talema Group – organization chart

Producer of toroidal components marked Talema Group in Europe

Production of TALEMA GROUP Producer of toroidal components marked Toroidal transformers for general use 1,6 VA – 10 kVA o Standard series: „55“ (2 sec.), „58“ (1 sec.), custom made types - Production: NT Magnetics Toroidal transformers for halogen lights o Standard series : „56“ (1 sec. 11,8V) - Production: NT Magnetics Three-phase toroidal transformers o Custom made types - Production: NT Magnetics Toroidal transformers for PCB 1, VA o Standard series : „5P 64“ (prim. 115V), „5P 65“ (prim. 230V) - Production: NT Magnetics o Standard series : „70“ (prim. 2x115V), „72“ (prim. 2x120V) - Production: Talema India Toroidal autotransformers o Custom made types - Production: NT Magnetics Toroidal current transformers o Standard series, custom made types - Production: Talema India Chokes o Standard series, custom made types - Production: Talema India ISDN and LAN components o Standard series, custom made types - Production: Talema India

Producer of toroidal components marked Production of TALEMA GROUP

Producer of toroidal components marked TALEMA transformers Basic technicle characteristics Maximum power of 1-phase: 10kVA Maximum power of 3-phase: 25kVA Maximum current: about 60A Maximum voltage: 1000V Frequence: core is made from metalsheet strip – standard Hz Secondary winding voltage: is define for certain load and for certain ambient temperature ( if not specified: 25°C) Electrostatic shield: between windings (prim. and sec.), done by copper tape, lead out connect to ground to eliminate el. disturbance Magnetic shield: to reduce level of electromagnetic field radiation, steel tape on outside girth of transformer Temperature fuse: reversible / nonreversible, connected to primary winding Mounting: „S“, „B“, „H“, „D“, encapsulated, into printed circuit etc.

Certificartes Producer of toroidal components marked

Quality control Most of the transformers are design in accordance with standars UL - registration UL: E , E , E Every transformer comply with standard ČSN EN ed. 2 and standards, which are required by goverment order no. 281/2000 Sb. Transformers of trademark Talema for healthcare comply with standard ČSN EN Every customer recieves „Declaration of conformity“ Products are made in accordance with technology of parent company; certificated by ISO 9001:2008 Documents control system in accordance with standards ISO 9001:2008

Phone : Fax : For more informations please visit: © 2011 NT Magnetics s.r.o. Producer of toroidal components marked Business philosophy of our company „Dedication to competitive growth to competitive growth of our customers„ of our customers„