INTRODUCING THE NEW MINI INVERTERS BY LIGHTALARMS

Slides:



Advertisements
Similar presentations
Online Emergency Lighting Inverter Three Phase 3 KW KW.
Advertisements

Stand-By Emergency Lighting Inverter Three Phase 3 KW – 125 KW.
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
Martin Afford – Emergency Lighting Products Limited LEDs used in Emergency Lighting Applications Division of the Lighting Industry Association.
DYNAMIC LOAD RESPONSE: As a result of the impressed inverter output wave form. Presenter: Dr Gawie van der Merwe.
LP33 Series UPS kVA 400Vac/CE
EXPERIMENTAL STUDY AND COMPARATIVE ANALYSIS OF TRANSFORMER HARMONIC BEHAVIOUR UNDER LINEAR AND NONLINEAR LOAD CONDITIONS.
Presented by DaTran Lighting. AGENDA Of the numerous illumination platforms currently available, only Solid State Lighting offers our nation the potential.
| 1 © 2013 Universal Lighting Technologies ULT Marketing LED Product Capabilities.
BASICS OF BALLAST TECHNOLOGY
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
Inverters. Inverter Functions Change DC to AC Change DC to AC Increases or decreases voltage from array voltage to: Increases or decreases voltage from.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
Power Electronics Lecture-11 Inverters Dr. Imtiaz Hussain
The First Central Emergency & Standby Lighting System Combining Storage Batteries & Generator Input 1 1.
Expanded UPS product line. The expansion of our UPS offering is intended to give our customers a more complete line of products for most of their installations.
ENERGY EFFICIENT LIGHTING LINEAR HIGH BAY LINEUP MLFHBLT86HEH – Basic 6 Lamp T8T8 MLFHBLT84HEH – Basic 4 Lamp T8 MLFHBLT56 – Basic 6 Lamp T5T5 MLFHBLT54.
Power Supply Design J.SHANMUGAPRIYAN.
Kyle Merkert ECE 791/792 Senior Design Project October 2009 – May 2010 Faculty Advisor: Dr. Wayne Smith.
INVERTER PO-1500 SERIES 4 LOCATED IN PORT SIDE NOSE COMPARTMENT PROVIDES 115V AC SINGLE PHASE, 400HZ IN CASE OF FAILURE OF BOTH ALTERNATORS EQUIPMENT.
Fall 2009 Module 8 Inverters. Converts the DC power produced by the solar modules into AC power used on the utility grid.
| 1 EVERLINE® LED Sign Tubes Training. Universal is a Member of the Panasonic Group LED Replacement Products Universal continues to expand our LED options.
Introducing SP Series NEMA 4X, High Performance Industrial Emergency Lighting.
| 1 Distributor Training Presentation EVERLINE LED Sign Tubes.
Auxiliary power supply (APS) Hossein Harimi 2014
HARMONIC MITIGATION USING PASSIVE FILTERS
LED Driver Training.
V7 UPS Sales Training.
LEDlescentTM T8 Ballast-Free Lamps
ULTRA RT8 LED 347V Recessed Downlight Kit
Online Emergency Lighting Inverter
EVERLINE® LED Emergency Drivers
PRESS RELEASE IRS2500 µPFC™ Control IC Reduces Noise Sensitivity for Cost Sensitive Electronic Ballast and SMPS Applications DATA SHEET HI-RES GRAPHIC.
Protecting you from the worst electrical problems
Online Emergency Lighting Inverter
بِسمِ اللهِ الرَحمنِ الرَحیم
A Patented Product.
Stand-By Emergency Lighting Inverter
UNIT-8 INVERTERS 11/27/2018.
Stand-By Emergency Lighting Inverter
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Harsh Environment Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Outdoor Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
A Patented Product.
Indoor Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
Online Emergency Lighting Inverter
Outdoor Power Conditioning Voltage Regulator
Harsh Environment Power Conditioning Voltage Regulator
Online Emergency Lighting Inverter
Online Emergency Lighting Inverter
Indoor Power Conditioning Voltage Regulator
Stand-By Emergency Lighting Inverter
The smart choice for demanding motor switching
Stand-By Emergency Lighting Inverter
Online Emergency Lighting Inverter
Stand-By Emergency Lighting Inverter
LED Driver Training.
EVERLINE® LED Emergency Drivers
Presentation transcript:

INTRODUCING THE NEW MINI INVERTERS BY LIGHTALARMS

Why a Mini-Inverter? WITH TODAY’S HIGHLY EFFICIENT LED TECHNOLOGY, MINI INVERTERS ARE A RELIABLE, ECONOMICAL, HIGH-PERFORMANCE CHOICE FOR EMERGENCY POWER Offers a broad range of capacity for maximum flexibility Provides 125W to 720W of emergency power for 90 minutes Can power many remotes including new LED low wattage luminaires Ideal for locations with limited space to house power systems

Why a Mini Inverter? Allows existing fixtures to be used as emergency lighting Preserves the aesthetics of high-visibility areas Can run existing normally-on light fixtures in a power failure, as an alternative to separate dedicated emergency lighting Powers LED fixtures and most light sources at 100%

Choosing The Right Backup Power System

Features Improved-Diagnostics/ Self-Testing System Design A variable test period based on code requirements is performed every 30 days (1 minute each month, 10 minutes after 6 months, and 90 minutes after 12 months) System Design Utilizes highly reliable solid state electronics The modules feature input and output protection, as well as measure and limit their own current

Features Capacity True Sine Waveform (250W and up) Starting at 125W up to 720W, 120V and 277V True Sine Waveform (250W and up) with less than 5% Total Harmonic Distortion (THD) for linear loads Construction: 14-gauge steel housing Input/Output voltage 120V 60 Hz or 277V 60 Hz Replacable output fuse protection Low Voltage Battery Disconnect Unit comes standard with electronic lockout and brownout circuits Improved-diagnostics non-audible is standard

Modified Sine Wave vs Pure Sine Wave A modified sine wave (sometimes referred to as a “simulated” sine wave is an AC current that is not a pure sine wave. Modified sine waves have some load limitations in regards to electronic equipment. Lighting loads, however, are typically unaffected by modified sine wave current (see note at the bottom). Pure Sine Wave: A pure sine wave is indicative of normal AC voltage. There are no load limitations with pure sine wave output. Note: Some fluorescent lamps / light fixtures that have power factor correction capacitors (such as old magnetic ballasts) may not be compatible with the modified sine wave.

Nexus Reliability Through Technology Nexus® allows for maintenance time and cost savings Ensures that the emergency lighting fixtures will perform when needed Nexus® can contribute to LEED certification and support sustainability objectives

Benefits Code Compliance High Performance Reduces testing/service time for a minimal maintenance cost, while ensuring that local safety codes are met Provides system reliability in a power failure condition High Performance Rugged, easy-to-maintain system Offers exceptional overload performance without the need to over-specify the rating Accept load to its full capacity when load feature power factor of 0.9 or more

Benefits Versatile Applications Maximum Light Output Can be used in almost every type of building Ideal for architecturally sensitive applications Lowers maintenance and testing costs Can be installed at a distance of up to 1000 feet, offering the opportunity to hide the unit from view and maintain the architectural design by powering normally-on luminaires Maximum Light Output Deliver 100% power / lumen output of the fixture up to the specified run time Compatible with all fluorescent ballast, LED drivers or incandescent light sources

Electrical Characteristics

How to Order

Marketing Tools Catalog Sheet Price List Training Presentation Website Introduction Video

Thank You! www.lightalarms.com