Viking TotalPac2 FireFlex Dual / 1230

Slides:



Advertisements
Similar presentations
ADVANCES IN ONSITE HYDROGEN GENERATION FOR UPPER AIR OBSERVATIONS WMO TECHNICAL CONFERENCE ON METEOROLOGICAL AND ENVIRONMENTAL INSTRUMENTS AND METHODS.
Advertisements

Design Constraints For Engineering Projects
Presentation On INERGEN
Fire Protection Solutions for Transformers „TrafoProtect“ by Minimax
Jason Holland Permian Production Equipment, Inc. Welding, Cutting and Brazing Safety.
A new opportunity from 3M 3M™ Novec™ 1230 Fire Protection Fluid Sustainable technology for special hazards A new opportunity from 3M Today, I.
Fire Suppression Techniques Part 2
Technology in Architecture Lecture 10 Mechanical Systems Lecture 10 Mechanical Systems.
Halon Systems Ch. 5, pages HALogenated hydrocarbON not the same as halogen F, Cl, Br, I 1940’s ’s extremely effective.
© Siemens Industry, Inc Confidential / Drive Your Business Forward Ignite the Power of New Products and Partnerships Siemens Fire Partner Summit.
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
CNG Refuelling station. A company located in Cherasco (Italy), is among the world leaders in the field of designing and manufacturing of components and.
Stages of Fire Detections and Extinguishants From Ginge-Kerr Danmark A/s & BMTT Corporation S/B (www. ginge-kerr.com)
Sustainability of Special Hazards Fire Suppression Systems
Hangar Water Based Fire Protection
In today’s global business environment, the need for clean agent fire suppression has never been greater. Pem All.
Chapter 9. Please read chapter 9.  Please review, know and understand the terms related to fire protection page 284.  Know the Classifications of.
Automatic Sprinkler Systems
Computer & Telecom Rooms. 2 Business or building protection ? BUSINESS PROTECTION  Smoke is the problem  Small and Medium Size (
LNG Hazards.
Clean Agent Fire Suppression Alternatives
Fire Suppression Systems Association PRESENTS:
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
Control Rooms  Serve as operations centers for the control and monitoring of a service or process  Flight control rooms  Power generation control rooms.
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
Inert Gas Fire Extinguishants
Kidde Engineered Fire Suppression System 25 bar Equipment Hardware Engineered for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Technology in Architecture Lecture 12 Electrical Equipment Electrical Power Management Fire Protection Systems Lecture 12 Electrical Equipment Electrical.
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
CXS490 Chemical Extinguishing System Halocarbon Extinguishing System
SINORIXTM CDT Product Presentation.
NEXT GENERATION Kidde Engineered Fire Suppression System Designed for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Novec 1230™ SYSTEM DESIGN 3M™ Novec 1230™ Fire Protection Fluid.
CXS490 Carbon Dioxide Systems
Chapter 15 Refrigeration Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
3M™ Novec 1230™ Fire Protection Fluid
1 CXS490 - Characteristic of Fire. 2 Other Resources NFPA Standards (available through Seneca Libraries Link NFPA Handbook Manufacturer’s Technical Information.
FIRE SERVICES AT DATA CENTRE
1 CXS490 - Pre-Engineered Fire Protection Systems Off-Road Vehicle Systems.
ADS / PHX SERIES SYSTEMS ADVANCED TOPICS. F O R T H E NEM ILLE NN I U M F O R T H E NEM ILLE NN I U M Advanced ADS / PHX Topics Halon retrofits Directional.
Kidde FM-200® Product Review
Fire Protection Systems Chapter 6. Fire Protection Systems Most of the time you will work with an electrical engineer or fire-protection designer to coordinate.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
NOVEC Fire Suppression System
2012 Lik Kai Pacific Sense March PACIFIC SENSE Company Intro.
For more information, please contact 14/12/2010 EN/CV/DC Technical specification IT-3684 by Elena Perez Rodriguez.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Hot /Cold Aisle Containment  Traditional Data Center/Telco designs are changing significantly!
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
50% LBNE Concept Design WCD Infrastructure. Mechanical.
Technology in Architecture Lecture 18 Fire & Life Safety Fire Protection Systems Lecture 18 Fire & Life Safety Fire Protection Systems.
Medium- and High-expansion Foam System Design
COMPRESSED AIR ENGINE (An engine which runs on Air only)
We are one of the accredited manufacturers and suppliers of Accoustic Enclosure and Sound Proofing in northern part of India under brand Name of "DDSTHA".
West Cambridge Data Centre Ian Tasker Information Services.
Chapter 14: System Administration Mark Milan. System Administration Acquiring new IS resources Maintaining existing IS resources Designing and implementing.
Halon Options Task Group Update Chapter 2: Halocarbon Replacements Tom Cortina Halon Alternatives Research Corporation IASFPWG Meeting May 11-12, 2011.
Water Mist Systems Chapter 6. Objectives Evaluate water mist as a potential halon replacement Discuss the applications for water mist systems Compare.
WELCOME. Glycol Refrigeration A most basic definition of refrigeration is taking heat from someplace we don’t want it and moving it to someplace where.
ODS & SGG Considerations for Changing a System
Pre-Engineered Novec 1230 & FM-200 March 1, 2012
Technology in Architecture
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Borbotech BV • Tel.: +31(0) • •
Subsea 100 Global Services Products Presentation
Presentation transcript:

Viking TotalPac2 FireFlex Dual / 1230 Technical Presentation ASPE Cleveland, OH March 10th, 2010 Viking TotalPac2 FireFlex Dual / 1230 Systems Inc. www.fireflex.com

1991 Light & Ordinary Hazard INTEGRATED SPRINKLER SYSTEMS History: 1990 Power Plants Unit 1991 Light & Ordinary Hazard 2002 Second Generation

Remote controlled unit INTEGRATED SPRINKLER SYSTEMS Expanding the concept: Extended range of configurations: Skid unit Remote controlled unit Self-contained unit

ICAF SYSTEM Description: Typical System Layout Air Cylinders Piping Network Distribution Nozzles Integrated Cabinet Foam Tank (water tank also available)

CAF TECHNOLOGY Description: Compressed Air Foam (CAF) Uniform & stable High momentum Excellent quality 10:1 expansion

Integrated Clean Agent Systems Clean Agent Integrated Fire Suppression Systems using 3M™ Novec™ 1230 Fire Protection Fluid Combined Automatic Sprinkler and Clean Agent Integrated Fire Suppression Systems using 3M™ Novec™ 1230 Fire Protection Fluid

CLEAN AGENT 3M Novec 1230:

Integrated Clean Agent Systems FireFlex 1230

Extinguishing Mechanism The Fire Tetrahedron Removing one of the required components for fire or disrupting the balance between them can cause a fire to extinguish fuel oxygen heat chain reaction Novec 1230 Fluid extinguishes primarily via cooling – removing heat from the fire 9

Compatible with fire system materials Non-corrosive Long term testing of compatibility with materials of construction (system hardware) Compatability with plastics confirmed 30 year shelf life in properly maintained and installed systems 10

Environmental Properties 3M NOVEC 1230 Environmental Properties Properties Novec 1230 (FK-5-1-12) Halon 1301 FM-200 (HFC-227ea) ECARO-25 (HFC-125) Ozone Depletion Potential 10 Global Warming Potential 1 6900 3220 3500 Atmospheric Lifetime (years) 0.014 65 29 33 EPA's SNAP Conformance Yes N/A

3M NOVEC 1230 Physical Properties Novec 1230 (FK-5-1-12) Halon 1301 FM-200 (HFC-227ea) ECARO-25 (HFC-125) Design % 4-6% 5 % 6.25-8.7 % 8-11.3 % NOAEL % 10 5 9 7.5 Occupants Safety Margin % 67-150 % Nil 3-44 % (NOAEL) No Observable Adverse Effects Level for acute toxicity, including cardiac senisitization

3M NOVEC 1230 Site refilling option

3M NOVEC 1230 If Novec 1230 fluid is banned from or restricted in use as a fire protection agent due to ozone depletion potential or global warming potential, 3M will refund the purchase price of the fluid.

CLEAN AGENT 3M Novec 1230: Pre-Engineered Discharge Nozzles: Available: 1", 1½" & 2" dia. 180° or 360° discharge pattern 32' x 32' spacing – 16'-4" max. height No piping below 8,500 cu.ft. !

FIREFLEX 1230 Engineered Systems: Larger or multiple room hazards or volumes Need some calculations/software required Re-use existing Halon 1301 piping at 500psi

CLEAN AGENT 3M Novec 1230: Engineered Discharge Nozzles: Available: ½", 1", 1½", 2" & 2½" dia. 180° or 360° discharge pattern 32' x 32' spacing – 16'-4" max. height Re-use existing Halon 1301 piping at 500psi

FIREFLEX 1230 Product Description: Fully Integrated Clean Agent System Only Factory Built & Tested

FIREFLEX 1230 Product Description: Sturdy Cabinet with Lock Competitively Priced Eliminates Site Coordination Issues

FIREFLEX 1230 Product Description: Integrated Potter PFC-4410 RC Releasing panel Detailed Instructions & Unit Serial Number Clean Agent Cylinder from 40 to 601 lbs cap. Sturdy Cabinet

FIREFLEX 1230 Available Configurations: Clean Agent Only – No Sprinklers Self-contained or Remote Controlled (no panel) Master-Salve Cylinders Available Main-Reserve Arrangement Available Pre-Engineered or Engineered Piping System

FireFlex® 1230 Cabinets Capacity (# of cylinders) & dimensions System dimensions and Capacity Table: FireFlex® 1230 Cabinets Capacity (# of cylinders) & dimensions Cylinder Size (lbs) Dimensions Cabinet Size 40 76 164 322 601 A B C 24" 1 -- 23" 25" 77⅛" 36" 2 35¾" 48" 46"

Integrated Clean Agent Systems FireFlex DUAL

FIREFLEX DUAL Product Description: Fully Integrated System Combines Preaction & Clean Agent Factory Built & Tested Serialized

FIREFLEX DUAL Product Description: Sturdy Cabinet with Lock Competitively Priced Eliminates Site Coordination Issues

FIREFLEX DUAL Product Description: Air Compressor Optional Common Integrated Potter PFC 4410RC Releasing Panel Detailed Instructions & Unit Serial Number Viking Preaction 2” & 3” Clean Agent Cylinder

FIREFLEX DUAL Available Configurations: Preaction Single or Double Interlock 2" or 3" dia. Sprinkler Valve Self-contained or Remote Controlled (no panel) Pre-engineered or Engineered Piping System

FireFlex® DUAL Cabinets Capacity (# of cylinders) & dimensions System dimensions and Capacity Table: FireFlex® DUAL Cabinets Capacity (# of cylinders) & dimensions Cylinder Size (lbs) Dimensions Cabinet Size 40 76 164 322 601 A B C 36" 1 -- 35¾" 25" 77⅛" 48" 46"

Standards, Approvals and Listings for Novec 1230 Fluid U.S EPA SNAP approved as alternative to halon in occupied spaces NFPA 2001 Standard on Clean Agent Fire Protection Systems ISO 14520 Standard on Gaseous Media Fire Extinguishing Systems FM Approved UL Listed IMO Recognized DNV Approved VdS Approved LPCB Approved CNPP Approved Bureau Veritas Approved Lloyds Approved 29

LISTINGS & APPROVALS Clean Agent (Sevo Equipment): UL & ULC Listed: 360 psi Pre-engineered Systems Engineered Systems by Mid-2010 FM Approved: 500 psi Pre-Engineered Systems Engineered Systems early 2010

LISTINGS & APPROVALS Potter Releasing Panel & Viking Preaction System: UL & ULC Listed FM Approved CSFM Approved NYC Accepted

LISTINGS & APPROVALS FIREFLEX DUAL & 1230 (Assembled Units): Pre-engineered System: c-UL-us (early 2010) FM Approved 500 psi Engineered System: c-UL-us & FM (early 2010) CSFM & NYC (early 2010)

APPLICATIONS IT Systems Mix rooms Pump Stations Switch Rooms & UPS Telecommunications Testing / Imaging equipment Transformer Vaults Etc… Cable racks Clean Rooms Clinical / Diagnostic equipment Control Rooms Data Centers Electric Utility facilities Generator & turbine enclosures

Information required for design Obtain specifications Approvals required, AHJ Determine if a reserve is required Identify hazard normal ambient temperature Obtain location altitude Obtain drawings, sketches of dimensions Qualify room size when quoting a job Obtain hazard areas, length, width, ceiling height Determine system location

Thank you ! Systems Inc. FIREFLEX DUAL & FIREFLEX 1230 by the same people who first brought you integrated fire protection systems www.fireflex.com