The Impact of Connector Quality on Network Elements Many thanks to Sherlon Kauffman of US Conec Ltd. and the Team at Fiber Instrument Sales Presented by.

Slides:



Advertisements
Similar presentations
TX40 and CX40 feature presentation. Multi-functional solution Unique product features - enhanced applicability.
Advertisements

Preventing Equipment Failures
Lesson 4 Computer Maintenance
© DIAMOND SA / / 1 F-3000™ Connector Family.
© DIAMOND SA / X-BEAM / / 1 X-BEAM Connector Up to 4 channels SM and MM optical connections based on Expanded Beam technology.
Industrial Graphic Solutions Designed to Meet Your Sophisticated Markings Needs. EXPECT MORE FROM MUIR..
Chapter 8 Optical fiber splicing Attenuation curve for silica optical fiber.
Procedures For Cleaning A Revolver By Sherry L. Goucher, Sr. CTO Oklahoma Dept of Corrections District V – Community Corrections Approved on July 9, 2001.
The DUCTZ (of the Upper Bay Region) Experience
MFS, MPO 4/8/12-Fiber connectors and Fan-Out assemblies.
© DIAMOND SA / / 1 Alberino CRA Alberino fixing system for modular constructions within industrial Mennekes housing.
SETUP Chapter 6 Lead Abatement for Workers Course.
1 Microscope Maintenance. Microscope Maintenance-Module 3 2 Learning Objectives At the end of this module, you will be able to Store the microscope properly.
1 Module 9: Microscope Maintenance. 2 Learning Objectives Learning Objectives At the end of this module, you will be able to Store the microscope properly.
V Cleaning Optics Includes excerpt from “The Clean Microscope” ( > Support > Download Center.
Maximize Effectiveness and Protect the Environment IV Pest Control Operators of California.
Zephyr Manufacturing Company, Inc. Microfiber Performance.
Pursuit of Better testing Instrument Let's go in the grandway......
1 NSF-MRSEC NCMN CLEAN ROOM OPERATING and safety TRAINING Jiong Hua Nebraska Center for Materials and Nanoscience University of Nebraska NCMN Facility.
TECHNICAL SEMINAR PRESENTATION-2004 Presented by :- Pradeep Kumar DashRoll # IT “ FIBER OPTICS BASED COMPUTER NETWORK” Instructor Mr. Dutikrushna.
Fiber Optics BASIC FIBER OPTIC LINK.
Laser Cleaving of Optical Connectors Didi Hachnochi VP Engineering & R&D Duane Dinkel President Sagitta Incorporated 655-H Fairview Road Simpsonville,
Bendix® ADB 22X™ Air Disc Brakes “Service Series”
Supply Chain Management Handbook (SCMH) Foreign Object Debris (FOD) Guidance Material Overview October
Chapter 10 Optical fiber measuring instruments and testing single-mode fiber networks.
© DIAMOND SA / / 1 CLEANING A focal point in fiber optics.
OPTICAL TIME DOMAIN REFLECTOMETER (OTDR)
1 Fiber Optics FIBER PERFORMANCE. 2 Fiber Optics The purity of optical fiber is critical for the best transmission of an optical signal inside a fiber.
Installation and testing
PC Maintenance: Preparing for A+ Certification Chapter 2: Safety and Preventive Maintenance.
Personal Protective Equipment
R espiratory Protection In Compliance With: 29 CFR Cummins Southern Plains, Ltd.
Optical Fiber Connections joints and couplers
The DUCTZ Experience. A Brief Overview of how DUCTZ Cleans a Heating and Cooling System.
Decontamination of filed equipment used in environmental site characterization and ground-water monitoring projects University of Arkansas 11/13/2006 By.
Electrical Safety.
2.00 Understand Computer Fundamentals
LOSSES IN FIBER OPTIC SYSTEM
1a.  Exposed part  Live or energized part  De-energized part 1a.
Scene Shop and Electricity Safety
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman ENVIRONMENTAL AND HAZARDOUS MATERIALS 7.
1-1-Why Maintenance HVAC ? Increases equipment life & reliability Reduces size & scale & number of repairs Lowers maintenance costs through better.
“ FIBER OPTICS BASED COMPUTER NETWORK”
Design Testing the theory Advantages Conclusion 2003 The Facts about Colortrac Open Aperture Open Aperture prevents streaks in the scanned image caused.
Chemical Sterilization
POWER TOOL SAFETY.
COMPUTER HARDWARE SERVICING
Fiber Optic Testing Optical Educational Seminar Tim Percival EXFO 18 th February 2016 BICSI Breakfast Meeting Lagos, Nigeria.
11 Rubber gloves and sleeves are a lineman’s first and foremost defense against electrocution For this reason rubber gloves and sleeves must be physically.
Product Manager – Fiber Optics MicroCare Corporation®
Brian Teague Product Line Manager – Sticklers® Fiber Optics
Best Practices for Cleaning MPO Assemblies, cassettes & transceivers
Best Practices for cleaning
Fiber optic.
Electrostatic charge test
Product Line Review August 2016.
best practice for cleaning
Case for using sticklers
Brian Teague – Product Line Manager November 2016
Infection Control in the GI Setting
Construction Safety Management
Module 9: Microscope Maintenance
Introduction to Computers
Cleaning Fiber optic connectors
Product Manager – Fiber Optics MicroCare Corporation®
Fiber Optic Connectors, Splices, and Tools
Lesson 4 Computer Maintenance
Brian Teague Product Line Manager – Sticklers® Fiber Optics
Basic Interferometry For PC Polished Connectors
Pneumatic System Conditioning
Presentation transcript:

The Impact of Connector Quality on Network Elements Many thanks to Sherlon Kauffman of US Conec Ltd. and the Team at Fiber Instrument Sales Presented by Jim Fasano, Director of Strategic Accounts

Training Objectives Identify the sources for poor connector performance such as various common contaminants that are in the environment Discuss and understand the impact that Optical Return Loss has on overall system performance (video signal degradation) Learn techniques and technologies developed to eliminate performance issues 2

Connector end face cleanliness effects performance: What is it? Where does it come from? Is it really that bad? Look familiar?? You are not alone… Fiber Optic Cleanliness, a Basic understanding of effects

Dust Particles Hand Lotion Skin Oil and Dead Skin Flakes Alcohol Residue Debris generated from normal wear in mating and de-mating Dry wall dust Saw dust Residues from end caps (outgassing) Skin oil Suntan lotion Alcohol residue Water residue Vegetable oil Hand lotion Dryer lint Saltwater residue Graphite Common Contaminants

Common Sources of Contamination 1. Mishandling Accidental touching transfers skin oil, hand lotion and vegetable oil Lint generated from organic wipe materials (i.e. T Shirt, Jeans) 2. Environmental sources Saw dust, sheet rock and paint fumes from construction Particle debris from cardboard boxes Dust in the air from HVAC systems Condensation 3. Poor technique and use of inferior grade cleaning products Oil droplets from canned propellant and outgassing of the rubber in the seals Cleaning solvent residues that are not completely wiped away Exposed containers of alcohol Fabric deposited (i.e. left behind) from cleaning cloths 4. Normal Wear By-Products Ferrule materials Adapter material (i.e. sleeve, guide pin wear on MT connectors) Connector components (i.e. springs, housing) Endcap abrasion or mold residue

Causes of Network Failure The chart above is a summary of a study from NTT-Advanced Technology that polled network owner and cable installers on the sources of network failures 98% of cable installers and 80% of network owners answered “Yes” to having contamination be the root cause of a network failure.

Impact of Dust Contamination Dust particles can cause problems in three ways: 1.Dust on the core region will block the signal path 2.Dust may prevent proper physical contact 3.Dust can cause scratches and pitting defects

Lasting Effects of Contamination Initial Clean Endface Contaminated Endface Mated 5 times dirty then cleaned results in severe permanent damage

Residue Contamination Liquid residues have different refractive indices than the fiber which can create problems during physical contact. Residue contamination commonly contributes to optical back reflectance. Examples of liquid and oil residues Example of dried alcohol residue

Residue Cross Contamination Connector A Before Mating Connector B Before Mating Connector A After Mating Connector B After Mating

What should a clean fiber look like? Zone A Zone B Zone C Zone D Notes: All the data assumes a 125µm cladding fiber Multimode uses 65µm to accommodate 62.5µm and 50µm Defect is defined as existing entirely within the inner-most zone which it touches Source: IEC Alternate source: IPC

Signal Degradation on an MT Fiber

BEST PRACTICES

Inspect. Clean. Inspect. 1.Always inspect both connectors before mating. 2.Mating dirty connectors may: –Cross contaminate both connectors –Scratch and pit the ferrule end face 3.Inspecting and cleaning before mating will: –Prevent permanent damage to connectors –Reduce trouble shooting time –Reduce material costs –Improve signal quality 4.Make keeping fiber optic connectors clean a priority. –Develop inspection and cleaning procedures –Train your team regularly on how to inspect and clean your connectors Inspect connector Clean? Mate Clean Yes No

Fiber Optic Cleaning Tools 1990’s & early 2000’s  Application:  (2) SC connectors (TX & RX)  Typical Cleaners:  Wipes, Swabs, CLETOP, “Other”

Dry Wipes Fabric-based and paper wipes that provide a mechanical action to absorb residues and trap dust particulates Examples include: Tissues, field cards, etc. ADVANTAGES: Cleans end face while disconnected from mating adapter Common technique in the industry Allows both dry & wet cleaning DISADVANTAGES: Cannot clean end face through mating adapter Untrained operators can damage fiber end face Must be protected from contamination until just prior to use Some wipes can deposit fabric on the end face (self- contamination)

Solvents / Wet Clean Solvents provide a chemical action to clean fiber optic connector end faces. Examples include: Water, alcohol, HFE, etc. ADVANTAGES: Provides more aggressive cleaning of contamination Very effective against oils and dried-on contamination DISADVANTAGES: Untrained operators can leave behind residue, which can be more difficult to remove than the original contamination A dry clean is always required after a wet clean (i.e. two sets of tools for the operator) May not be portable enough for some applications May violate some customer MSDS requirements Some solvents are flammable Some solvents have storage and/or shipping limitations Isopropyl Alcohol Residue

Sticks & Swabs Swabs may be beneficial for cleaning connector end faces installed in adapters ADVANTAGES: Cleans the ferrule end face while installed in mating adapters Allows cleaning of some specialty connectors without requiring disassembly of the connectors DISADVANTAGES: Cannot clean end face while disconnected from mating adapter Can be more costly than other methods Limited cleaning effectiveness due to the physical constraints of the adapter Some swabs can deposit fabric on the end face (self- contamination)

Cleaning Cassettes Relatively mature cleaning technology using a reel of specialty fabric Examples include: OPTIPOP, CLETOP & NEOCLEAN ADVANTAGES: Low cost per clean Faster cleaning times Better consistency in cleaning performance Refill packs for even lower cost per clean DISADVANTAGES: Cannot clean end face through mating adapter

NEXT GENERATION TOOLS

Refillable / Mechanical Cleaning Tools NEW technology with optional refill cartridges Examples include: NEOCLEAN-E Series tools ADVANTAGES: More eco-friendly Cleans end faces in both mated (with adapter) and unmated conditions Simple, One-hand operation Faster cleaning times Consistent cleaning performance DISADVANTAGES: Some tools have limited cleaning region Some tools do not have a good method for keeping material on the track

Mechanical Cleaning Tools Relatively new technology that advances a cleaning cloth across the end face in a controlled fashion Examples include: IBC™ Brand Cleaning tools ADVANTAGES: Cleans end faces in both mated (with adapter) and unmated conditions Simple, One-hand operation Faster cleaning times Consistent cleaning performance Custom tools can be developed for specialty connectors DISADVANTAGES: Some tools have limited cleaning region Some tools do not have a good method for keeping material on the track

Selecting a Cleaning Methodology What connector types will need to be cleaned? What type of contaminates will my technicians encounter? Where are the connectors physically located in the network? How many connector ends will need to be cleaned for this project? What type of environment have the connectors been exposed to? What type of environment will my technicians be cleaning in?

Optical Return Loss and Reflection impact on Systems 24 What is Optical Return Loss? What is Reflection? What is the impact on Systems? Why are connectors/splices of concern?

Overview 25 Optical Return Loss is the Total % of Power reflected back from points along an optical path. Optical Return Loss and Back Reflection impacts: - Transmission Systems with Laser Transmitters -Any Analog transmission system (video) -Any system where there is a high concentration of interconnecting points Effects! - Increased receiver noise and an increase in Transmitter noise - Poor video clarity in Analog systems, Pixilation in Digital video - Overall loss of optical power, increasing cost and complexity of active optical components as well as minimizing distances between points.

Minimizing Optical Return Loss 26 Minimize reflective points by: -Maintain clean and contaminant free optical connector ends -Eliminate mechanical splicing of any fiber (Connector terminations, field splices, etc.) -Minimize connection points and unnecessary splices -Educate all technicians of the importance of “Optical Return Loss” and potential effects. Any Questions?

Thank you