Discovery 1-4 Loop Analogue Addressable Control Panels

Slides:



Advertisements
Similar presentations
Prescient II Extinguishing Control Panels
Advertisements

Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
ID to 8 Loop Intelligent Fire Alarm Panel
Eagle Trading & Agencies has been established from the ground up for selling, managing and implementing mid to large size projects in the field of fire.
Static Transfer Switch
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Motorcycle product sheets
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
WELCOME A Security Masterpiece. Control Panel Line-up Max Zones Basic Zones Max Zones Basic Zones n 1725EX14 6 (4 + 2) n 1728EX15 7 (5 + 2) n 1738EX16.
6000 Series Recorders. The Best Paperless Graphic Recorder in the World.
MDR-304 Digital Video Recorder. Can do: - Reliable real time recording of vehicle interiors & surrounding road environment. - Removable recorder unit.
Reliability Different worlds – same problem …one solution: Redundancy
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Digital video security systems 2 Multi-functional CCTV Management System The Most Complete Integrated Digital CCTV Management System.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
Advanced Workgroup System. Printer Admin Utility Monitors printers over IP networks Views Sharp and non-Sharp SNMP Devices Provided Standard with Sharp.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Training.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Precept Conventional Control Panels
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Graphical Alarm Management System
ONYX Product Overview.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
Guide to MCSE , Second Edition, Enhanced 1 Objectives Understand and use the Control Panel applets Describe the versatility of the Microsoft Management.
Fire Detection Presentation
An Introduction to the Windows-based PC Programming Tool Version 0.91
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
System Features Interactive Digital Addressable Fire Detection and Alarm System. Designed for Small and Medium Sized Installations.
FG Wilson Access 4000 Control Panel
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
Eclipse EHX System Logic Maestro. Module Objective Introduce Logic Maestro to the user Elements ► What is Logic Maestro ► How does Logic Maestro relate.
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
University of Management & Technology 1 Operating Systems & Utility Programs.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
KIDDE FIRE PROTECTION Vega Peer to Peer Networking.
CB200 Conventional Control Panels
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
2 December, 2015 New Conventional Fire Control Panel.
Precept Marine Conventional Control Panels
CB200 e Cabinet Extinguishant Control Panels Designed for cabinet extinguishant systems 2 zone extinguishant co-incidence operation Selectable discharge.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
1 Industry leading Temperature & Humidity Control and Monitoring with Ethernet in-built Phasefale JouleTemp Click left mouse button to advance, “back”
MCS-Connect Revision - 12/22/2015.
Display System for 6400/6300 Protec Alarm Control Systems. Series of Graphic Screens shows all Addressable Devices and their status indication Complicated.
FireClass Addressable FC501 Part 2 - Panel Use. FC501 Engineering 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions.
Confidential Document 1 EverAccess Product Overview By Rodney Guinto.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Product Training AI50 Author Job title Please ensure mobile phones are switched to silent.... Thanks!
ICAICT201A USE COMPUTER OPERATING SYSTEM. USING THE CONTROL PANEL The Control Panel contains many options for configuring your computer, including: adding.
Reveal™ Touch Screen Product Overview
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
ACOE347 – Data Acquisition and Automation Systems
Presentation transcript:

Discovery 1-4 Loop Analogue Addressable Control Panels From 1-4 loops LPCB approval to EN54 2 & 4 Fully compatible with all Apollo XP95 and Discovery devices Extensive mode-change options by day/night and special group allocations Day/Night delay of alarm and cause/effect outputs 4 Inbuilt Software Delay Timers 500mA output per loop with highly stable voltage platform, even under mains-failed conditions

Discovery 1-4 Loop Analogue Addressable Control Panels Additional Discovery detector functions Print Drift Compensation level by loop Print Device Date of Manufacture Enable/Disable LED pulsing mode Automatic recognition of Apollo and Control Equipment outstations User friendly controls and a clear, unambiguous screen Fully networkable with other Discovery and Voyager panels Complies with EMC and LVD Directives Windows-based, full upload/download PC software package

Discovery 1-4 Loop Analogue Addressable Control Panels New Phase 5 Software upgrade 61 customer Led Enhancements Including:- Fast loop output response (3 seconds with BGU operation Latest Apollo devices supported including intelligent reflective beam, discovery CO detector, XP95 multisensor etc Local cause / effect enhanced to 3 x capacity General output disablement facility Configurable class change – pulse / continuous Full loop sounder synchronisation supported

Discovery Panel Hardware Up to 14 fully functional repeater panels may be connected via RS485 cable. Up to 31 8-way panel enhancement boards may be added. Two types are available: 1) fully-programmable inputs and relay outputs 2) fully-programmable inputs and alarm outputs Fully programmable network comprising other Discovery and Voyager panels, graphics systems and network repeaters. Individual panels and Integra networks are programmable via Windows PC package.

Mechanical Assembly Motherboard and power supply located on a removable chassis to assist cabinet installation. Motherboard holds up to 4 loop cards Display assembly located on the removable door. LPC approved high specification switch mode power supply. Zonal LEDs and optional printer are located on the display board. Space for internal 12Ah battery set.

Fully Flush Cabinet (Illustrated) Cabinet Options Surface Cabinets Cabinet colour reference is: RAL 7035 textured (Light Grey) All cabinets are manufactured from sheet steel and finished in satin texture epoxy powder stove paint. Semi-Flush Cabinets The semi-flush bezel locates to the rear of the bevelled edge of the back box, leaving the bevelled edge and door raised out from the wall. It is finished in the same colour as the back box and is fitted by means of pinch bolts, thus avoiding the need to drill the cabinet. Fully Flush Cabinet (Illustrated) Custom-made to a high quality, full-flush bezels are available in brass, stainless steel, or painted. This option is achieved by fixing a flat bezel assembly to the standard back box, replacing the standard door. The panel comes with assembly already fitted but may be supplied for later on-site fitting (this may be a little time-consuming). For details of panel dimensions see Application Guide.

System LED indications are provided in addition to the LCD display. User Controls The backlit LCD display gives information of loop, device and zone number, device type and event condition, together with a user-definable text description. The text descriptions give the user clear, easy-to use functional controls. The engineer accesses panel configuration functions using the numerical designations. The menu structure on the LCD display guides the engineer through the different set-up facilities. System LED indications are provided in addition to the LCD display.

LCD Display The device types which may be indicated are as follows: SOU - Loop sounder/sounder circuit controller O/S - Input/Output device ION - Ionisation smoke sensor MON - Monitor (zone monitor, control monitor) OPT - Optical smoke sensor HEAT - Heat sensor BGU - Call point or call point monitor

System LED indications are provided in addition to the LCD display. Zone Indications The Discovery panel is available with or without the slide in zone indication chart System LED indications are provided in addition to the LCD display. The printer slot and printer location studs are available for easy printer fitting

Printer This good quality printer uses a reliable Epson mechanism. Hinged access to allow easy ribbon change. Engineer’s printer test button. Open access to feed paper through mechanism. Designed for easy replacement of the paper roll onto the carrier. This button advances the paper.

RS485 comms from panel motherboard. A1535 8 Way Relay Board RS485 comms from panel motherboard. Engineer’s DIL switches to set board address, enable O/C or S/C inputs and disable inputs/outputs. 8 inputs may be normally open or normally closed and will register as fire or non-fire on the panel as configured. Inputs are fully programmable via the panel or PC cause/effect. 8 x 1Amp changeover relay outputs may be fully programmed via the panel or PC cause/effect programme. Engineer’s links to disable functions for set-up or maintenance purposes. 24V DC power.

A1536 8 Way Alarm Board Engineer’s DIL switches to set board address, disable inputs and outputs, test LEDs and test alarms. Engineer’s DIL switches to isolate alarm outputs individually. RS485 comms from panel motherboard. 8 x 1Amp two-stage alarm outputs may be fully programmed via the panel or PC cause/effect. 8 normally open inputs which will register as fire or non-fire on the panel as configured. Inputs are fully programmable via panel or PC cause/effect. Alarm Fault LEDs. Test alarms when switched to 0V. Engineer’s buzzer disable link for set-up or maintenance purposes. 24V DC power.

Extensive User’s Menu User Functions Time/Date Delay Delay Enable/Disable Day/Night Modes Enable Day/Night/Auto/Off Enable/Disable Devices Zones Printer Sounders View View Event Log View Suppressed Events Test Point Walk Test Alarm Walk Test Print Clear Print Queue Print Event Log Print Disablements User functions to disable individual loop devices, a range of devices, full zones, the printer and sounders. User function to read the output delay and to enable or disable its operation. User function to select the DAY mode, NIGHT mode, AUTO mode via timer, or OFF (XP95 default settings). User function to operate one man device test and alarm audibility test.

Overview of the Engineer’s Menu 1. PANEL SETUP 1. LOOP SETUP 1. Loop Configuration 1. Loop Contents 1. View Loop Contents 2. Print Loop Contents 1. Reconfigure Loop 2. Device Sensitivity (XP95/Discovery) 1. Fire 2. Alert 3. Discovery 1. Print Drift 2. Print Date 3. LED 4. Rapid Compensation 2. Zone Allocation 1. Edit Device Zones 2. Print Device Zones 3. View Device Zones 3. Loop Cause Effect 1. Device Group Allocation 1. Edit Device Groups 2. Print Device Groups 3. View Device Groups 2. Loop Output C/E 3. Print Loop O/P C/E 2. I/O SETUP 1. Remote Evacuate Mode 2. TEXT EDIT 1. EDIT COMPANY NAME 2. EDIT Device TEXT

Windows-based PC Programming Windows-based PC programming package for panel set up, zones, text, local and network cause/effect, Discovery mode types, sensitivity levels and day/night timings.

Discovery Mode-change Maps The discovery panel provides the engineer with the facility to set a mode sensitivity map for: Day use - for example, less sensitive in some process areas during working hours Night use - for example, maximum sensitivity throughout entire building when not in use Default - ignore day/night sensitivity maps, set to XP95 equivalent The engineer may set up each device into a day map, and night map, and set the clock (week day or weekend options) to switch between them

Discovery Mode-change Maps The end user may easily select between: Day mode - manually holds all devices in the Day mode setting Night Mode - Manually holds all devices in Night mode setting Automatic - Day/Night mode determined by clock Off - To manually set all devices to default (XP95 equivalent)

Discovery Temporary Mode Changes Loop outstation inputs may be configured to change Discovery Multi-sensor modes. Applications: - Loading Bays - As a lorry enters, smoke detection may be temporarily disabled Theatre Stages - Stage hand may operate key switch to de-activate smoke detection at performance times Hotel Function Rooms - Keyswitch at room entrance to disable smoke detection during special events Smoke Cloak Security - Multisensor smoke elements may be disabled when the smoke cloak is activated

Networking “All talk - selective listen” No Master panel or P.C. required and thus no single Device of failure Up to 15 active panels or 60 loops may be networked together plus an additional 17 passive nodes Discovery panels, Voyager panels, network repeaters and Alarm Manager graphics systems Conventional panels, extinguishant panels and other equipment via network repeater and/or loop I/O Full event and cause/effect programming across network RS485 data communications Network repeater with up to 248 programmable inputs and 248 programmable outputs

Typical Network Illustration RS485 comms to panel repeaters and expansion cards. Discovery, and Voyager panels may be networked together with Network Repeaters, Alarm Managers (Graphics) PCs. Network repeater with up to 248 programmable inputs and 248 programmable outputs. RS485 network comms. Engineer’s programming via PC.

Network Repeater Up to 31 8-way panel enhancement boards may be added to the Integra Network Repeater. All inputs and outputs are programmable across the network. Two types are available: 1) fully-programmable inputs and relay outputs 2) fully-programmable inputs and alarm outputs A typical application shows the 8 way boards linked to fireman's controls, LED’s, alarm sounders and plant shut down. The LCD provides user and engineer facilities. Devices may be isolated across the network via this network repeater.

Instantly accessible current event log. Alarm Manager This is a mouse or touch-screen driven system that does not require keyboard after set-up. The drawings are inserted as bitmaps and may be copied from CAD and edited within Windows. The Alarm Manager (graphics system) may be individually tailored to customer’s requirements and is configured with password protection. The event priority and thus its display colour are determined by the nature of the event. The site procedure pages give user instructions for each type of event. User controls are configured if required via password set-up. Multi-level password protection may be configured for each type of function. Up to 5 map pages may be allocated for each individual device on the network (4 allocated here). Map pages may be used for drawings or specific instructions as required. Instantly accessible current event log.

Typical Radio Pager Configuration The radio pager system, when connected to the control panel, can be used to transmit both text and numeric messages direct to pocket pagers. Pagers will display Fire / Fault conditions including Sensor location text. Up to 9,999 pagers can be connected to system. Connection to panel (printer or PC port, dependent upon panel). Transmitter Interface board Opto isolator

XP95 Test Tool The XP95 Test Tool is an engineer’s tool to assist with commissioning and fault finding on XP95 loop systems. Loop configurations and the status of each device may be interrogated, device LEDs may be turned on/off. The test tool may be connected to an entire loop without the panel connected or connected to individual devices around the circuit. Alpha-numeric LCD display. Sockets for flying leads to connect to loop and/or individual XP95 devices. Engineer’s keypad. Battery charger socket. On/off switch and LED indication.

More About Programming For more about the Windows-based, full upload/download PC software package click here