Installation. Indoor Unit Installation Typical Installation.

Slides:



Advertisements
Similar presentations
Sectional Assembly and Installation
Advertisements

ACTIVE LEARNING PROCESS
CHAPTER 45 Engine Lubrication.
Basic Electricity.
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
Assembly Manual Mike Fortney 04/09/2004 CricketSat Receiver.
Optimum Round Pool Instructions. Prepare the pool site Remove all the grass on a surface 2’ wider than the size of the pool Level the ground.
AC-SSC-1 Installation and operation manual
1 HVACR316 – Piping Tubing and Piping. 2 Purposes of Tubing and Piping Provides a path for refrigerant to take Provides a means to return oil to the compressor.
Frame Assembly Produced by Ed Latimer, Team 476 Ken York, Team 476 Ron Markum, Team
RockOn! Canister Integration RockOn! 2009.
Optical Manufacturing Solutions 1 Probe Assembly.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Page 1 MDS Installation. Page 2 Contents  Introduction  Outdoor Unit Installation  Indoor Unit Installation  Refrigerant Pipe Work  Gas Charge 
Left Side Discharge Pressure Regulator
Click on this image to open the full PDF document.
1 STEPMILL 7000 PT ASSEMBLY INSTRUCTIONS PART NUMBER
3” BACKWASH VALVE WITH SUPERSTAR ACTUATOR BASIC SERVICE MANUAL Does not apply to PLC-MP version SUPERSTARS.
MyLock 644D Service Seminar.
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
Cooling Business Group 1 INSTALLATION Directions.
TUBING AND PIPING.
Air tank installation instructions Included parts: Raw aluminum air tank bracket 5/16-18 button head bolts (qty 4) M8x1.25 button head bolts (qty 4) M8.
ASSEMBLY INSTRUCTIONS. 2 ASSEMBLY INSTRUCTIONS TOOLS REQUIRED: SIDE CUTTING PLIERS PRY BAR 7/16” & 9/16” WRENCH 3/16” ALLEN WRENCH T-15 TORQUE.
Inside-, Depth-, and Height-Measuring Instruments
"AIR COOLER" Heat Exchanger
Condensation Piping and Installation Drain Pans
Steering Columns.
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
Service Seminar Memory Craft Table of Contents MC10001 Top Cover Removal…………………………………………………………………..…………1 Belt Cover Removal……………………………………………………………..……………2-4.
General idea of a couple of check rod system and adjustments
Installation. Indoor Unit Installation Typical Installation.
Presentation on Installation of a Domestic Cold Water Storage Cistern
TP4-ENERSOL-TD/PV double function
AIR CONDITIONING (COOLING)
MC11000 Kit Replacement 1 1. Open the face plate and remove the 2 screws. Remove and discard the original face plate. 3. Remove the 2 white caps on the.
Title: Corvette C5 Column Lock Bypass Originator: John Neese Date: 30 Jan 2005 Revision: Sheet: 1 of 6 Column Lock Bypass.
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman IN-VEHICLE ENGINE SERVICE 27.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
Installation. Indoor Unit Installation Typical Installation.
Plans for the 2015 Invention Challenge Target Paul MacNeal August 9,
CHAPTER 33 Drum Brake Systems.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
PARKING BRAKE OPERATION, DIAGNOSIS, AND SERVICE
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Framed Canopy Fitting Instructions Contents – 6- Angled frame fixing brackets 1 x handle pack 6 x self drilling tech screws 3 keys 1x door 6 x coach screws.
RADIATION SOURCE Design Review Dmitry Gudkov BE-BI-ML.
CLM Maintenance. Covers : 1 - Side cover, 2 - Back cover, 3 Top cover, 4 - Lamp door, 5 - Side cover input and communication side, 6 - HEPA dust filter,
Service Manual. Cubi Overview The service manual instructs the installing and removing the mSATA, memory card, Wifi card and 2.5 inch HDD.
Compressor Replacement – ODU
XR621 Drive Hose Update Kit. Removal Turn off Battery dis Drain hydraulic tank Remove both rubber lines under chassis and discard. Remove and discard.
Easy Reach 7.0 Honda Element Packing List QtyDescriptionPacked 115ft 10ga Red Wire 16ft 10ga Black Wire 140amp Breaker 23/8 Yellow Ring Terminals 25/16.
Suggestion for installation Demolish and destroy the old air condition, then send them to owner building Install a new one by last main.
Rapid Change Technology The following is a presentation to aid Technicians in the replacement of the Rapid Change Technology Block.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
Ferrari Testarossa 1987 OS Giken Clutch Replacement Document Version
VIEW SERIES with Sliding Door
Scorpion is a remote tester specifically designed for testing ASD systems. Scorpion is compatible with the FAAST aspirating smoke detector. It is particularly.
CAUTION GENERAL TOOLS REQUIRED ASSEMBLY AND INSTALLATION
IRFTS SHADOW SOLAR Garden
IN-VEHICLE ENGINE SERVICE
Easy Reach 7.0 Honda Element 2003
Easy Reach 7.0 Honda Element 2003
Soxhlet Unit B Maintenance By: Shawna Brookes.
Cassette Type Room Air conditioner 14th August 2016, Kuantan, Pahang.
CAUTION GENERAL TOOLS REQUIRED ASSEMBLY AND INSTALLATION
Assembly instructions for M-K all bolt together hoppercone kit.
HYBRID COOKTOP.
Reader Swap out Guide.
Presentation transcript:

Installation

Indoor Unit Installation Typical Installation

Indoor Unit Installation Installation Procedures Indoor Unit Adequate Support! Building structure must be adequate to support the weight of the unit. Failure to ensure adequate structural support could result in unit falling from its location which could result in death, serious injury, or equipment or property-only damage. 1.Avoid locating the indoor unit where the return and/or supply air may be obstructed. 2.Select a location where it is easy to drain the condensing water and connect to the outdoor unit. 3.Keep the indoor unit far away from heat sources, vapor and flammable gas. 4.Be sure that the installation of the indoor unit conforms to the installation dimension diagram. 5.Be sure to leave enough space to allow access for routine maintenance. 6.Install in a location where the unit is more than 3 feet away from other electric appliances such as television, audio devices etc. 7.Select location where air filters can be easily removed.

Positioning for mounting cassette unit Step 1 Indoor Unit Installation Select a ceiling location suitable for the installation of the indoor unit. (Refer to the installation manual for location and dimension spacing.) Locate building support members sufficient to hold 4 times the weight of the unit being installed. Mark the location for the support brackets / downrods.

Positioning for mounting cassette unit Step 2 Indoor Unit Installation Mount the support brackets, downrods and nuts. (Field supplied.) Double-nut the top of each bracket. Be sure that the brackets / downrods have been fixed firmly enough to withstand 4 times the weight of the unit, furthermore, the weight should be evenly shared by each downrod. Install the nuts and washers on the lower ends of the downrods with enough spacing to allow the cassette unit brackets to slide between the sets of washers. Double-nut the bottom nuts.

Installing cassette unit Step 1 Indoor Unit Installation Raise the cassette unit into position, placing the downrods in the bracket slots of the cassette unit. Hand tighten the nuts so that the downrods will not come loose from the brackets.

Installing cassette unit Step 2 Indoor Unit Installation Check and adjust the unit for proper height according to the installation guide and verify unit is level.

Installing cassette unit Step 3 Indoor Unit Installation Tighten all nuts on the downrods. Make sure to lock the double-nuts together at all 8 locations on the downrods.

Drilling a hole in the wall to install the piping Step 1 Indoor Unit Installation Find the location on the exterior wall where the piping and wiring will exit the building. Drill a 2 ½” diameter hole at a slight downward angle from the inside wall towards the outdoor wall so that the outside hole is a ¼” lower than the hole on the in side.

Drilling a hole in the wall to install the piping Step 2 Indoor Unit Installation Insert a sleeve into the hole to prevent the connection piping and wiring from being damaged while being inserted through the hole.

Drilling a hole in the wall to install the piping Step 3 Indoor Unit Installation Pass the piping and wires through the hole using caution to ensure tubing, wiring and insulation is not kinked or damaged. Insulate the piping hole both inside and out after the piping connections have been completed at the indoor and outdoor units. Note: Image for illustration purposes only. The entire drain line tubing must be wrapped to prevent moisture from cool condensate coming in contact with and damaging the ceiling or wall.

Installing the water drain pipe Step 1 Indoor Unit Installation Attach the flexible drain pipe coupling to the condensate pump drain port using the supplied clamp.

Installing the water drain pipe Step 2 Indoor Unit Installation Insulate the connection with the supplied gray insulating material.

Installing the water drain pipe Step 3 Indoor Unit Installation Attach the condensate drain pipe to the flexible drain pipe coupling. The diameter of the condensate drain pipe should be equal to or larger than the flexible drain pipe coupling. Support the drain pipe to avoid drooping or sagging of the line. Support the pipe every inches as needed.

Installing the water drain pipe Step 4 Indoor Unit Installation Should the pipe slope between the cassette unit and the wall exit hole point be insufficient, the pipe may be raised to allow for proper drainage. The raised pipe height should form a right angle to the unit and be less than 11 inches. (See diagram.)

Installing the water drain pipe Step 5 Indoor Unit Installation The slant gradient of the flexible drain pipe coupling should be below 2.9 inches so that the drain hole fitting of the cassette unit does not have unnecessary force applied to it.

Installing the water drain pipe Step 6 Indoor Unit Installation Refer to the above diagram when installing multiple indoor units with a common drain line. Check for proper drainage after completion of the drain pipe installation.

Installing the connection pipes Indoor Unit Installation A flaring kit may be necessary for the installation of the lineset.

Installing the connection pipes Indoor Unit Installation Note: First connect the connection pipe to the indoor unit and then to the outdoor unit. Pay attention to the pipe bending. Be sure to not damage the connection pipe. To avoid leakage be sure not to over-tighten the joint nut. Note: Refrigerant lines should be separately insulated. Once the piping has been connected to the outdoor unit and a leak test has been performed, slide the insulation over the joints to completely insulate the connections. Step 1 Align the center of the piping flare with the relevant fitting. Screw in the flare nuts by hand and then tighten the nuts with a spanner and torque wrench. Refer to the chart for proper torque.

Installing indoor unit wiring Step 1 Indoor Unit Installation Remove the two screws and cover plate, revealing the main PC board and terminal block.

Installing indoor unit wiring Step 2 Indoor Unit Installation The cassette unit is capable of using a wired remote. If installing this option, feed one end of the remote’s wire into the electric box through one of the wiring grommets located on the side of the enclosure. Plug the wire into connector C9.

Installing indoor unit wiring Step 3 Indoor Unit Installation Firmly attach the power connection cables to the terminal block in the indoor unit, making certain to observe the proper terminal connections as shown on the unit wiring diagram. Note: In addition to the outdoor breaker/fuse disconnect, a breaker or fuse is required for each indoor unit. The installation must be done in accordance with National, State, and/or local codes.

Installing indoor unit wiring Step 4 Indoor Unit Installation The electric wire must be tightened securely with the wire restraining clip.

Installing indoor unit wiring Step 5 Indoor Unit Installation Reattach the cover plate to the electric box.

Installing indoor unit cover panel Step 1 Indoor Unit Installation Remove the two retaining screws from the cover filter panel release tabs.

Installing indoor unit cover panel Step 2 Indoor Unit Installation Slide the two release tabs toward the center of the cover panel. Remove the center filter panel.

Installing indoor unit cover panel Step 3 Indoor Unit Installation Place the cover panel on the cassette unit noting the position of the louver motors and the wiring harness. (The cassette unit has recessed areas where the louver motors fit.)

Installing indoor unit cover panel Step 4 Indoor Unit Installation Screw the cover panel onto the cassette unit using four screws.

Installing indoor unit cover panel Step 5 Indoor Unit Installation Plug the wiring harness connectors together.

Installing indoor unit cover panel Step 6 Indoor Unit Installation Reinstall the filter cover and replace the retaining screws.

Installing indoor unit cover panel Step 7 Indoor Unit Installation Perform final inspection of the cassette indoor unit making sure all mounts are secure.