Darkroom and Film Processing

Slides:



Advertisements
Similar presentations
PROCESSOR CHEMISTRY.
Advertisements

RADIOGRAPHIC FILM PROCESSING DARKROOM
Processor, Sensitometry,
Darkroom Film processor
IMAGE ARTIFACTS.
Main components of the tube head
Chapter 20 Film Processing.
Processing the Latent Image Dr Mohamed El Safwany, MD.
PROCESSING THE IMAGE SENSITOMETRY WEEK
DARKROOM ,PROCESSING & Artifacts REVIEW
Week 10 a Artifacts.
The Chemistry of Photography. Black & White Film Black and white film is composed of 4 layers. *An upper protective coat. *A layer of gelatin that contains.
Robert Metzger, Ph.D. Roland Wong, Sc.M.
Chapter 14 Processing the Latent Image
Radiographic processing
Film Processing Chapter 7.
Film processing 2.
RADIOGRAPHIC PROCESSING
Image Formation Differential Absorption of X-rays by the Patient  Absorption of non-attenuated x-rays by screen  Emission of light  Formation of Film.
Radiographic processing Processing equipment. Typical manual processing unit.
Chapter 11 The X-ray Darkroom.
The Darkroom. Photosensitive Paper Kept in a safe to protect from white light. Emulsion – Covered in a gelatin and silver-halide crystals – Crystals trap.
Dental X-ray Film Processing
Darkroom: A light-tight room containing the equipment to develop photographs.
Chapter 12 Darkroom Procedures.
Processor Quality Control Problem Solving Midterm Topic 2.
Dental X-Ray Film Processing
About the 35mm Manual Film Camera Nickie Cardano Greyson Shane Per. 4.
INTRO TO THE DARK ROOM Photography 1.
Processing The Latent Image
FILM PROCESSING GOING BUT NOT OBSOLETE YET. LET’S REVIEW NAME SOME COMPONENTS OF THE STRUCTURE OF THE FILM NAME SOME COMPONENTS OF THE STRUCTURE OF THE.
Radiographic Film DMI 50B Kyle Thornton. Some History Photography began before x-rays were discovered Certain silver compounds react to light making image.
Image Receptor Systems
RAD 354 Chapt 11 Radiographic Film/Receptor Image forming rays: remnant beam/exit radiation – scattered radiation (partially absorbed/attenuated) and non-interacting.
Darkroom and Film Processing Rad Tech A – Week 9 Fall 2010.
Physical Characteristics of X- Ray Film & Film Processing
Processing the latent Imaging. Processing the Latent Image The processing of the latent image produces the manifest image. The exposed silver ions in.
Quality Assurance in the Dental Office
FILM CASSETTES & INTENSIFYING SCREENS WEEK 9
RAD 254 Chapter 12 Processing the Film Latent Image Basics/Dates Universal time and temp: 5 min at 68 degrees F Each MAJOR step is 2X longer than the previous.
Dental radiology د. باسم الاعسم.
Dental radiology د. باسم الاعسم.
Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and Hygienists, Ninth Edition Evelyn.
Processing of films Definition of processing Processing theory Diagram.
Image Receptors Film Construction, Film Handling, Cassette Construction, DarkRoom, Digital Imaging 1.
Darkroom and Film Processing Rad Tech A – Week 10 Fall 2007.
IMAGE ACQUISITION FILM SCREEN SYSTEM. PROCESSING THE LATENT IMAGE AUTOMATIC AUTOMATIC DARKROOM PROCESSOR DARKROOM PROCESSOR DAYLIGHT PROCESSOR DAYLIGHT.
1 PHOTOGRAPHY Part 2: PHOTOGRAPHY Part 2: The Chemistry of Photography.
THE FINAL STEP: IMAGE PROCESSING
DENTAL X-RAY FILM PROCESSING
DARK ROOM TECHNIQUES-PROCESSING
Film Processing.
Dr Mohd Malik. Format 1. Latent Image Formation 2. Dark Room 3. Processing Solution  Developer  Fixer.
RADIOGRAPHIC EQUIPMENTS
Quality Assurance in Dental Radiography
Film, Cassettes, and Developing Processes
Processing the Image Chapter 8
Darkroom Construction Since x-ray films are more sensitive to light than most photographic films, it is important to have a good darkroom.
Film Development Objectives:
Radiography Dentalelle Tutoring.
DENTAL X-RAY FILM PROCESSING
Stacy Kopso, M.E.d. RT(R)(M)
Darkroom and Film Processing
Film and Film Processing
Creating the Image Unit III.
Processing Radiographs
PROCESSING.
DARK ROOM AND CHEMICAL PROCESSING Dr. pushpender singh
Presentation transcript:

Darkroom and Film Processing Rad Tech A – Week 9 Spring 2009

Darkrooms – Still Necessary? Darkrooms are necessary for manually fed processors and daylight processors. -Loading automatic film processor magazines. Necessary for conducting certain quality control tests (daily sensitometric strip).

Darkroom

Darkrooms 4 Basic Functions Number 1 Function Storage Unexposed film

Purpose of Film Processing DARKROOM FUNCTION # 2 Purpose of Film Processing Change silver halide crystals from film emulsion (after exposure to x-ray or light photons) to black metallic silver. Latent image (invisible until processed) is developed into a Manifest image. Improper or careless processing can cause poor diagnostic quality.

Manual Feed Processor

Hand Processing in the Early years Strong smell of chemicals Messy Time comsuming

1956 – first roller transport 6 minute processing time

Processing Time 3 minutes 90 seconds

Processing Film Table top Processors Can process as fast as 60 seconds TABLE TOP PROCESSOR

PROCSSING CHEMICALS Solutions are PRE- MIXED Outside Company usually provides service- Weekly or monthly Solutions should be replenished as necessary & changed regularly Solutions must be monitored (Daily QC strip).

Replenishment tanks

TABLE TOP FILM DUPLICATOR to MAKE COPIES OF FILMS

WILL THIS WORK ????

Daylight Processor

Function # 3: Handling of Film

UNLOAD EXPOSED FILM

Pass Box

LOAD CASSETTE

Function # 4: Film Identification Pt name Exam date & time Pt x-ray number Pt Birthday/DOB Rt or Lt marker Optional Exam type Dr. Name

FILM ID PRINTER Name of patient place on top Cassette is “flashed” with name – can be done before or after image is taken Must be done BEFORE PROCESSING FILM

AUTOMATIC PROCESSING WASHER DEVELOPER DRYER FIXER REPLENISHMENT SYSTEM TRANSPORTATION SYSTEM DEVELOPER FIXER WASHER DRYER REPLENISHMENT SYSTEM

Automatic Processor

Processor Chemistry Overview Developer – converts latent image into manifest image Fixer – clear the film of unexposed, undeveloped silver bromide crystals, promotes archival quality Wash – rid the film of residual chemicals

Developer Solution (6 Ingredients) Reducing Agent: reduce exposed silver halide to black metallic silver -Hydroquinone (Blacks) -Phenidone (Grays) 2. Activator: softens gelatin, maintains alkaline pH (increase pH) -Sodium Carbonate

Developer Solution 3. Hardener: prevents damage to the film from over swelling of gelatin in automatic processors. -Gluteraldehyde 4. Preservative: Antioxidant that prevents oxidation of developer -Sodium Sulfite

Developer Solution 5. Restrainer: prevents chemical fog in new developer -Potassium Bromide 6. Solvent: dissolves & ionizes the developer chemicals -Water

Fixer Solution (5 Ingredients) Clearing Agent: dissolves undeveloped silver halide -Ammonium Thiosulfate 2. Tanning Agent: shrinks, hardens, preserves emulsion -Aluminum Salt

Fixer Solution 3. Activator: neutralizes developer, maintains acidic pH (decrease pH) -Acetic Acid 4. Preservative: prevents oxidation, prolongs solution life -Sodium Sulfite 5. Solvent: dissolves other ingredients -Water

Wash Rid the film of residual chemicals Residual chemicals on the film will discolor radiograph over time. Cold water processors are less efficient in removing chemicals – Warm water processors much better. Agitation during wash process is essential

Fixer Retention (Not Washed Off)

Transport System Components Feed Tray Rollers (Different Assemblies): 1. Entrance 2. Deep Racks 3. Turnaround 4. Crossover 5. Squeegee 6. Dryer Receiving Bin

Transport System (Rollers) Entrance Crossover Feed Tray Squeegee Deep Racks Dryer Turnaround

Processor (Top View)

Replenishment System Main function: Keep solution tanks full and assure proper solution concentration. As film is introduced into processor, sensor initiates solution replenishment Right & wrong way to feed in film -Feed in along short edge

Transport System in Automatic Processors Conveys the film through different solutions (sections) by a series of rollers driven by gears, chains & sprockets. Done at a prescribed speed – determines length of time the film is in each solution

Temperature Regulation Main function: To control the temperature of each section of the processor. Developer – most important solution to regulate Usually between 92 degrees and 95 degrees Thermostatically controlled

Recirculation System Provides agitation necessary for uniform solution concentration

Wash & Dryer Systems Wash: Provide thorough removal of chemical solutions from the film. -Archival film quality Dryer: Removes water from film by blowing warm, dry air -Between 120 degrees & 130 degrees F.

Silver Recovery About ½ of the film’s silver remains in the emulsion after exposure & processing. Other ½ (unexposed silver) is removed from the film during fixing process. Silver is toxic to public water supply – must have proper disposal. Silver can be harvested from the fixer tank and recycled.

What is in the Darkroom?

Darkroom Contents Loading Bench Film Bin Film I.D. Printer Safelights Pass Box Light-tight Room Ample ventilation Warning Light outside room Lockable Door Wall Shielding if adjacent to x-ray room Walls painted with light color to reflect safelight

Darkroom Equipment

SAFELIGHTS

Safe Light 15 Watts Red filter Must be 3-6 feet from counter top or feed tray of processor Used to be amber or orange filter

Darkroom Summary

Summary & Questions

X-ray Cassettes cross section review layers What are the 4 layers? Of FILM & SCREENS ?

Film cross section

RTA LAB 2 Next Week : PROCESSING & SCREEN EXPOSURE IONIZING LAB INTENSIFYING SCREEN DARKROOM PROCESSING & CHEMISTRY COMPLETE IN CLASS WORKSHEET