Design Of Foundation for a Commercial and Residential Building

Slides:



Advertisements
Similar presentations
SUB-STRUCTURE foundations.
Advertisements

Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
Graduation Project Thesis: Structural Analysis & Design of “Al-Mansour Mall”
2.2 STRUCTURAL ELEMENT BEAM
Design of foundation for Fattouh building in Nablus
An-Najah National University Faculty of Engineering Civil Engineering Department Graduation Project Foundation Design for Western Amphitheater of Nablus.
Nablus tower is a multi storey building of 21 stories. These stories produce heavy loads above the soil. This building is relatively heavy if we compared.
An-Najah National University
Chp12- Footings.
Foundation Engineering CE 483
Foundation System Design for Al Nimmer Commercial Building
Abstract This project is a structural analysis and design of a residential building located in JENIEN City, The building is consisted of 7 floors. The.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Chp.12 Cont. – Examples to design Footings
Reinforced Concrete Design II
FOUNDATION The foundation of a structure is the lowest part of the sub-structure interfering with the soil and the structure. It consists of some structural.
Foundation Engineering CE 483
FOUNDATION DESIGN.
ERT352 FARM STRUCTURES FOUNDATION DESIGN
Footings.
Commercial Foundations
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
University of Palestine
Reinforced Concrete Design
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Abstract *Our project is about ( Foundation Design of Al- Maslamani Mall) which is located in the village of Beit Eba – Nablus governorate. *The total.
Graduation Project Thesis  
Chapters Project title : Hirbawi Center A building lies in the east side of Tulkarm, this building consists of five stories of ( m 2 ) A building lies.
Prepared By: Mohammed wafiq omer Mahmoud hammad Abd Algani Sami Malath omair An-Najah National University Faculty of Engineering Civil Engineering Department.
Tulkarem Multipurpose Sport Hall Prepared by: Moatasem Ghanim Abdul-Rahman Alsaabneh Malek Salatneh Supervisor: Dr. Shaker Albitar.
Structural Design of Movenpick Hotel
◦ Ar-Rafedain building is 8 stories reinforced concrete building,located in Nablus city and used as commercial and residential building. ◦ The basement.
Graduation project: Jaba’a Institution Supervised by: Dr. Riyad Abdel-Karim Awad Dr.Sameer El Helw Dr.Sameer El Helw By :Fadi Hamaydi.
An-Najah National University Faculty of Engineering Civil Engineering Department.
An-Najah Nationa Unuversity Faculty Of Engineering Civil Engineering Department Nablus-Palestine Foundation Design of Multy story building Suprevisors:
An-Najah National University Faculty Of Engineering Civil Engineering Department Al-Najjar Building Footing Design Systems Alternative Prepared by : Mohammed.
 The site is located in Tulkarem city.  The building consists of seven stories, and the area of each stories is about 700 m 2, the aim of this research.
FOUNDATION Engineering Design of shallow foundation
 General description of the project.  Structural system.  Geotechnical conditions of the site.  Design of two types of foundation.
Isolated footing with axial load and moment
Footing.
SANKALCHAND PATEL COLLEGE OF ENGINEERING,
Mahatma Gandhi Institute of Technical Education & Research Centre
AR362 - Structural Systems In Architecture IV Lecture : Foundations
BUILDING CONSTRUCTION
سایت جامع دانشجویان و مهندسین عمران Footing Design
Civil engineering department Foundation Design of Al – Jasser Building
An-Najah National University Faculty of Engineering
DR. JIVRAJ MEHTA INSTITUTE OF TECHNOLOGY
Design of Reinforced Concrete Foundations
SEMINAR ON FOOTING.
Design of shallow foundations for optical and nursing faculty
Soil MECHANICS AND FOUNDATION ENGINEERING-II (CE 311) [6] Types of Foundations 1437-Summer SaMeH.
An-Najah National University Engineering College
Analysis and Design of Al-Affori hotel
FOR 5TH SEMESTER DIPLOMA IN CIVIL ENGINEERING
Arch205 Materials and building construction 1 foundation
Arch205 building construction foundation
  An-Najah National University Faculty of Engineering
An-Najah National University Faculty Of Engineering
Foundation Design of Law and Media College
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg.
An-Najah National University
Supervisor: Dr. Mahmoud Dweikat.
An Najah National University Submitted to : Dr.Munther Diab .
An-Najah National University
Civil Engineering Department
بسم الله الرحمن الرحيم RaRami Abu Baker An- Najah National University
OUTLINES - location & Description. Material properties.
Structural Design I Course Code: CIVL312 Dr. Aeid A. Abdulrazeg.
Presentation transcript:

Design Of Foundation for a Commercial and Residential Building An-Najah National University Engineering Collage Civil Engineering Department Design Of Foundation for a Commercial and Residential Building Under the Supervision of: Dr. Mohammad Ghazal Prepared by: Moayad Qadarah Raja’e Omar Lu’ai Abu Sharshuh May 2011

Project Description Name: Eisheh Taha Oudeh Building. Type: commercial and Residential Building. Location: Nablus City, Rafedia Main Street, opposite to Ben Qutaiba School. Number Of Floors: 12 floor, 2 under ground level and 10 over. Plane Area: 550 m2 for the floor.

SCOPE OF PROJECT Evaluation of foundations. Selection of the proper foundations. Design of foundations.

Literature Review Foundations are the part of an engineered system to receive & transmit loads from superstructure to the underlying soil or rock . There are two types of foundations : shallow & deep foundations. Many factors should be taken into consideration in choosing foundation types such as soil properties , economic factors, engineering practice, ....etc

Types of footing Isolated Footing. Combined Footing. Mat or Raft Foundations. Strap or Cantilever Footings. Pile Foundations.

Isolated Footings Are used to support single columns. This is one of the most economical types of footings and is used when columns are spaced at relatively long distances. Its function is to spread the column load to the soil , so that the stress intensity is reduced .

Combined Foundations Are used in the following cases: 1) When there are two columns so close to each other & in turn the two isolated footing areas would overlap. 2) When the combined stresses are more than the allowable bearing capacity of the soil. 3) When columns are placed at the property line.

Mat or Raft Foundations Are used to spread the load from a structure over a large area, normally the entire are of the structure . They often needed on soft or loose soils with low bearing capacity as they can spread the loads over a larger area. They have the advantage of reducing differential settlements.

Strap or Cantilever Footings Cantilever footing construction uses a strap beam to connect an eccentrically loaded column foundation to the foundation of an interior column . Are used when the allowable soil bearing capacity is high, and the distances between the columns are large .

Pile Foundations They are long & slender members that are used to carry & transfer the load of the structure to deeper soil or rocks of high bearing capacity, when the upper soil layer are too weak to support the loads from the structure. Piles costs more than shallow foundations; so the geotechnical engineer should know in depth the properties & conditions of the soil to decide whether piles are needed or not.

Bearing Capacity Bearing Capacity : is the ability of a soil to support the loads applied to the ground . Ultimate bearing capacity is the theoretical maximum pressure which can be supported without failure; Allowable bearing capacity is the ultimate bearing capacity qu divided by a factor of safety (F.S). There are three modes of failure that limit bearing capacity: general shear failure, local shear failure, and punching shear failure.

Settlement When building structures on top of soils, one needs to have some knowledge of how settlement occurs & how fast settlement will occur in a given situation. So, There are three types of settlement: 1. Initial settlement 2. Primary settlement 3. Secondary settlement

Settlement (Cont.) Total Settlement = SI + SC + SS The allowable bearing capacity and the type of foundations provided later are evaluated based on the settlements limits. This means that the settlement of the proposed foundation would be within the acceptable limits if the allowable bearing capacity provided is used.

Geotechnical Investigation The studied area is approximately flat with slight difference in the three existing elevations. The general soil formation within Highly fragmented weathered limestone and marlstone of soft to medium strength with cavities filled with marl soil The geotechnical engineer decided to drill Three boreholes trying to cover the whole construction area.

The depths of the drilled boreholes were as follows: Borehole No. Depth (m) 1 16.0 2 10.0 3 laboratory test results: γ= 20 KN/m³ qall. = 3.5 kg/cm2

Taking the lowest compressive strength value of rock core specimens with test results and applying the percentage of 5%, the strength will be: b.h1 – Qall = 5% * 75 = 3.75 kg\cm2 b.h2 – Qall = 5% * 70 = 3.5 kg\cm2 b.h3 – Qall = 5% * 78 = 3.9 kg\cm2 But considering the fact that rocks is some areas may be encountered in fragmented conditions, as well as the presence of there fracture rocks and marls, it is recommended to consider the bearing capacity value of the rock formations countered in the site of not more than 3.5 kg\cm2 within the described rock layers after the removal of all loose fill materials over the rock.

Structural design Column loads are calculated using (sap program), the structure subjected to the following loads: 1) Dead Load (own weight). 2) Super imposed dead load =350 kg/m2. 3) Live load =500 kg/m2. Using ACI code, the ultimate loads are calculated considering load combination : Pu =1.2Dead + 1.6Live. Material characteristics used in this project are: f’c =240kg/cm2 (B 300) Where: f’c is the compressive strength of concrete fy = 4200 kg/cm2 fy is the yield strength of steel

Isolated Footing Design Manual Design steps: Area of footing = Total service loads on column / net soil pressure Determine footing dimensions B & H . Assume depth for footing. Check soil pressure. Check wide beam shear : Vc > Vult Check punching shear : Vcp > Pult, punching Determine reinforcement steel in the two directions. Check development length .

DIMENSIONS OF SINGLE FOOTING Area (m2 ) L(m) B(m) Footing column 2.7 1.8 1.5 F1 c1 F2 c2 2.52 1.4 F3 c3 1.7 F4 c4 F5 c5 2.23 1.65 1.35 F6 c6 20.25 4.5 F15 C15 14.76 4.1 3.6 F16 c16 18 4 F19 c19 13.3 3.8 3.5 F20 c20 10 2.5 F28 c28 F31 c31 10.23 3.3 3.1 F34 c34 10.5 3 F35 c35 7.02 2.6 F36 C36

THICKNESSES OF FOOTINGS Depth of footing will be controlled by wide beam shear (one way action) and punching shear (two way action). Wide Beam Shear: Shear cracks are form at distance “d” from the face of column, and extend to the compression zone, the compression zone will be fails due to combination of compression and shear stress. Punching Shear: Formation of inclined cracks around the perimeter of the concentrated load may cause failure of footing. Max, formation of these cracks occurred at distance “d\2” from each face of he column.

THICKNESSES OF SINGLE FOOTINGS h(m) d(m) Footing column 0.4 0.32 F1 c1 0.3 F2 c2 F3 c3 F4 c4 F5 c5 F6 c6 1 0.9 F15 C15 F16 c16 F19 c19 F20 c20 F28 c28 F31 c31 0.8 0.7 F34 c34 F35 c35 0.6 0.5 F36 C36

Steel reinforcement : Isolated footing represented as cantilever, so the max moment occurs at the face of the column: Ultimate moment at the face of the column (Mult) =(qult*ln2)/2 Mn =Mu\Φ , where, Φ=0.9 Mn =Rnbd2 ρ = 1\m(1-( 1-2mRn\ fy ).5) WHERE ρ: Steel ratio m= fy\0.85 f′c As = ρbd

single footing reinforcement: Reinforcement in long direction/cm Reinforcement in short direction/cm Footing 1ø16/27 1ø14/21 F1 1ø16/28 1ø14/20 F2 F3 F4 1ø14/27 F5 F6 1ø18/12 1ø18/10 F15 F16 1ø18/13 F19 1ø16/11 F20 F28 F31 1ø16/12 1ø14/10 F34 F35 1ø14/12 F36

DESIGN OF COMBINED FOOTING column Fc1 C7,C8 Fc4 C23,C24 Fc5 C26,C27 Fc6 C29,C30 Fc7 C32,C33 SUMMARY OF DIMENSIONS h(m) d(m) L(m) B(m) Footing .8 .7 6.8 2.5 Fc1 11.5 Fc2 1.5 1.4 6 4.5 Fc3 7 2 Fc4 Fc5 9 3 Fc6 Fc7

Steel Reinforcement (Flexural) By using sap program to get the maximum negative and positive Moment Mn =Mu\Φ , where, Φ=0.9 Mn =Rnbd2 As = ρbd Steel reinforcement for Fc2 The figure below show bending moment in x-direction using SAP2000:

The figure below show bending moment in y-direction using SAP2000: Mu =93.175ton.m Mn =93.175\.9 =103.52ton.m Mn =Rnbd2 Rn =21.1kg\cm2 Ρ =.0054 As =37.8cm2 Use 1 Φ16\12cm The figure below show bending moment in y-direction using SAP2000:

Steel reinforcement for Fc2 Mu =144.822 ton.m Mn =144.822/ 0.9 160.913ton .m Mn =Rnbd2 Rn=20.1kg\cm2 Ρ=.005 As =37.5cm2 Use 1 Φ16\12cm

Steel reinforcement for Combined footing Reinforcement in y direction Reinforcement in x direction Footing # 1Ф16/12cm Fc 1 1Ф18/10cm 1Ф22/10cm Fc2 Fc 3 1Ф32/10cm Fc 4 Fc 5

Calculating the Thickness for mat Mat foundation Design In this project the mat foundation was designed using Sap2000 with the following data: ( fc= 240 kg \cm2, fy= 4200 kg\cm2 ) Calculating the Thickness for mat The thickness of mat foundation was calculated using check for punching in the next calculation . (the most critical for determining the thickness for mat in the punching shear ) To calculate the thickness , it was used the next equation: Pu = .75*1.06(fc).5 *bo*d

Pu : the load at the column bo: parameter of the bunching area Where : Pu : the load at the column bo: parameter of the bunching area d: thickness of the mat foundation for mat foundation 1which include (col 21,22,25) Col 21 has the critical load ,Pu = 377.29 ton 377.29*1000 = .75*1.06*(240).5*(2(d+50)+(2(d+70))*d d = 80 cm

Design of mat foundation using sap 2000 Deflection shape When we do the analysis using sap 2000 it was found that the maximum settlement was equal to 0.0055 m

Reinforcement reinforcement in x direction we take the maximum moment at the face of columns and the maximum between the columns. Then ,the area of reinforcement will calculate by the Equation: As =p*b*d 1)at the face of column Mu =123 ton .m p= 0.0054 As = 0.0054 *100*80 As = 43 cm2 use 10Ф25 mm/m 2)between the columns Mu = 40 ton.m P =0.0016˂0.0033 So use pmin = 0.003 As=26.4 cm2 use 10Ф18 mm/m

reinforcement in y direction 1)at the face of column Mu = 75 ton.m ρ= 0.0032 ˂ 0.0033 use ρ min for all the zone. As = ρ * b * d = 0.0033 * 100 * 80 = 26.4 cm2 Use 10 Ф 18 mm / m secondary reinforcement (Negative moment) the max. moment equals to 20 ton.m Ρ = 0.0015 ˂ 0.0033

Thank you for listening