Presentation is loading. Please wait.

Presentation is loading. Please wait.

Isolated footing with axial load and moment

Similar presentations


Presentation on theme: "Isolated footing with axial load and moment"— Presentation transcript:

1 Isolated footing with axial load and moment
Design Input Grade of concrete - 35 Grade of steel - 460 Allowable soil pressure – 200 KN/m2 Column load – 1260 KN(D.L+L.L) Moment – 100 kN.m Condition about overburden of soil - No L&T-GES

2 Design procedure Checking the footing area Arrive footing size
By ACI 318 Design procedure Checking the footing area Arrive footing size Total load=wt of footing+column load Average soil pressure q= total load / footing area Allowable soil pressure > Average soil pressure Then footing are is ok L&T-GES

3 Finding factored loads
Factored column load=1.4xdead load+1.7xlive load Average factored soil pressure qnet=Factored column load/footing area Average dv=total thick – cover - bar dia Eccentricity e = Mu/Pu Solving two equations to get q1 and q2 Service load equation Vertical equilibrium L&T-GES

4 Check for One way shear Check for Two way shear
Take the critical section as ‘d’ distance from the face of the column (as per ACI 318 ) 1.find pressure at critical section 2.find Vu 3.find Vu If Vu>Vu Check for Two way shear Take the critical section as ‘d/2’ distance all around the face of the column (as per ACI 318 ) find pressure at critical section Find the value of bo 2.find Vu 3.find Vu is smallest of these L&T-GES

5 Safe against two way shear Otherwise increase the depth
L&T-GES

6 Check for flexural reinforcement
Max moment occurs at the face of the column Find average pressure Find required moment Mn=Mu/ Find required Ast Min Ast=0.0018bh Max spacing=18 in Development length L&T-GES

7 Isolated footing with axial load and moment
Word document (IS Method) Word document (ACI method) Spread sheet (ACI method) STAAD output (ACI method) L&T-GES

8 Final comparison 3366 mm2 CODE manual design and spread sheet design
STAAD DESIGN Area of steel IS 456 3366 mm2 Not available in STAAD ACI 318 5.55 in2 ( mm2) 5.15 in2 ( mm2) % difference in steel quantity 10.6% 1.3% L&T-GES

9 Thank You L&T-GES


Download ppt "Isolated footing with axial load and moment"