Fault Locating Overview

Slides:



Advertisements
Similar presentations
Chapter 20 Electric Circuits.
Advertisements

1. Tuesday: Halloween Shoot due TOMORROW. You must make a contact sheet of your photos and print it from my computer tomorrow. -5 pts for every day I don’t.
FACTORS.
B M O C Navigation Overview By Monica Spicker 2010.
L 25 Electricity and Magnetism [3] Electric circuits what conducts electricity what doesn’t conduct electricity Current, voltage and resistance –Ohm’s.
Electricity Chapter 34.
DC electronics. Resistance Because electrons have mass and are held in place by polarity “bonds” – energy is consumed to dislodge electrons Resistance.
D. Roberts PHYS 121 University of Maryland PHYS 121: Fundamentals of Physics I September 6, 2006.
GAMMA & ROAD TUBE BASICS TRAINING
Network topology.
PHSAUTOMOTIVESALSPHSAUTOMOTIVESALS Charging System tests & Voltage information Checking the charging system with just a volt meter.
Lesson 3 Measuring and Calculating Electricity. Next Generation Science/Common Core Standards Addressed! §CCSS.ELA Literacy.RST.9 ‐ 10.3Follow precisely.
Dealer Certification Section 2: Building the Network Physical Planning & Documentation Power Sources & Distribution Voltage Drop Calculations Copyright.
RESISTANCE. The resistance of a conductor is the ratio of the potential difference across it to the current flowing through it.
RESISTANCE – OHM’S LAW Lesson 5. Resistance  The amount of current flow in a circuit, and the amount of energy transferred to any useful device, depends.
L 26 Electricity and Magnetism [3] Electric circuits Electric circuits what conducts electricity what conducts electricity what doesn’t conduct electricity.
Current Electricity Introductory Physics Canadian Academy Group Members: Daiki Kieran Kebin V.
Resistance and Ohm’s Law Alessandro VoltaAndre Ampere Georg Ohm.
Translating Problems into Equations and Solutions
SERIES, PARALLEL, AND SERIES-PARALLEL CIRCUITS
Module 7 – Power Systems: Tethers
Chapter 21 Electricity. Opposite charges attract, like repel Charged objects can cause electrons to rearrange their positions on a neutral object.
Wind and Hydro Power Technologies Spring 2011.
The Law of Sines! Homework: Lesson 12.3/1-10, 12-14, 19, 20
Chapter 8 Ohm’s law describes the relationship of
Unit 7: Electricity and Magnetism
Electric Circuits.
Electrical Power Systems
Chapter 26 DC Circuits. Units of Chapter EMF and Terminal Voltage - 1, Resistors in Series and in Parallel - 3, 4, 5, 6, Kirchhoff’s.
1 Trigonometry Basic Calculations of Angles and Sides of Right Triangles.
Resistance in Electrical Systems Chap 4.3. Objectives Explain the difference between conductors, insulators & semiconductors. Define electrical resistance.
DC electronics Resistance and Capacitance. Resistance Because electrons have mass and are held in place by polarity “bonds” – energy is consumed to dislodge.
Communication Markets Division © 3M All Rights Reserved. 965AMS Product Overview.
Cable Rehabilitation at Oncor by Richie Harp – Distribution Standards Data provided by Mark Darilek – Maintenance Planning SWEDE 2009 – Tulsa, OK – Thursday,
Current Electricity Electric Current Circuit – continuous conducting path between terminals of a battery (or other source of EMF) Electric Current.
Open the software and click “close” after reading the tip. The screen below will come up. You may want to load a sample bridge design for starters. You.
11/22/2004EE 42 fall 2004 lecture 351 Lecture #35: data transfer Last lecture: –Communications synchronous / asynchronous –Buses This lecture –Transmission.
Communication Markets Division © 3M All Rights Reserved. 965AMS Autotest Training.
Lesson Measuring and Calculating Electricity. Interest Approach § Have you or your parents ever been using several appliances in the kitchen and had a.
Circuits : Series vs Parallel
Principles of Physics. So far, we’ve talked about non-moving charge We know that charged objects :  exert an electrostatic force on each other  move.
Electric Current and Circuits Ch. 18. Electric Current A net flow of charge Variable = I Unit = Ampere (A) I = Δq/Δt Conventional current is the direction.
ELECTRICITY SYMBOLS We have looked at several different symbols We will be using many of them from now on so get used to them.
Electrical Circuits ~Moving Charge Put to Use The Circuit All circuits, no matter how simple or complex, have one thing in common, they form a complete.
Cable for UPAMD Steve Sedio Foxconn 8/02/2011. Requirements: Power, 25 milliohms max – AWG selected by worst case resistance and operation at 50C Signal.
 The opposition of a material to the flow of charge through it.  Measured in ohms (  ).
ELECTRIC CURRENT AND CIRCUITS TOPIC 1 – ELECTRICAL ENERGY AND VOLTAGE TOPIC 2 – CAPACITANCE TOPIC 3 – CURRENT AND RESISTANCE TOPIC 4 – ELECTRIC POWER TOPIC.
Electricity Coulomb’s Law Chapter 5. Coulomb’s Law Magic? (a)The two glass rods were each rubbed with a silk cloth and one was suspended by thread. When.
The basic components of an atom are:  Protons  Electrons  Neutrons Atoms are held together by electric force. Electric force is one of the most powerful.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
LOCATION OF CABLE FAULTS
Series and Parallel Circuits SNC1D. Series and Parallel Circuits Key Question: How do series and parallel circuits work?
ELECTRICITY.
SERIES, PARALLEL, AND SERIES-PARALLEL CIRCUITS
Conductive & Non-conductive pipe locating concepts
CH 5 – Electricity and Magnetism
QQ Two wires of equal length are made from the same material. How is it possible for the wires to have different resistances? If a circuit has a voltage.
Electric Circuits.
Electric Circuits Exploration Go to the interactive. You will use only need to use the battery, lamp (bulb), and wire. Complete.
Resistance in Circuits
Conductance / Resistance / Factors
Current Attenuation and ACVG Surveys Gary Moss
Calculations: Transformers and Service Conductor Calculations
ELECTRICAL Currents & Energy
Chapter 20 Circuits and Circuit Elements
Electrical Stopping Power Electrical Resistance
Resistance in Circuits
Electrical Stopping Power Introduction to Resistance
Chapter 17: Introduction to Electricity
Topic 3.3: Key Concepts Chemical Energy separates electrical charges in cells. Charges can flow through conductors, but not insulators. Moving electrical.
Presentation transcript:

Fault Locating Overview 965AMS Fault Locating Overview Presented by Gary Morris

Outline Fault Locating RFL TDR

Fault Locating When to Use TDR and RFL Opens and TDR for Capacitive Faults RFL and TDR for Resistive Faults

When to Use TDR or RFL You should know what fault or condition you have before trying to isolate with the RFL or TDR. TDR RFL Load Coil Yes No Tip/Ring Open Water Bridge Tap High Res Opens Short = or < 500 Ohms Tip Ground Ring Ground Battery Crosses

TDR Press the TDR key Choose Setup to enter cable information. When finished choose a test and press OK

TDR Trace Examples - Open Here is a pair the is open at 1780 feet.

TDR Tip Open Here is a pair the has an open tip open at 780 feet.

TDR Series Resistance Here is a pair the has a high resistance open at 950 feet.

TDR Short Here is a pair the has an short at 1000 feet.

TDR Water Approximately 100 Feet of water.

Expert Pair Test

RFL Fault Locating Tips RFL test is used for faults under 20 mΩ. Always draw a diagram of the fault for better analysis. There three factors that is always involved in RFL (Resistance Fault Locating) - Gauge, Length and Temperature of the cable. Any two of the three must be known for RFL to work. The best option is to know the Gauge and Length of the section under test and the test set will compute the cable temperature. This is done during RFL Setup. A pair may have some light faults in it but it can be used as a ‘Good Pair’ as long as the light fault is at least 200 times better than the magnitude of the fault in the faulted pair. Ex: If the fault on a pair is 1 kilo-ohms, a pair with a 200 kilo-ohm fault can be used as a good pair. Of course, the higher the magnitude, the better. For best RFL accuracy , make a long cable section shorter by going to the middle of the section and open the pair to cut it in half. Check for the fault in one direction and then the other and then isolate the clean side. Repeat the process until the cable section becomes short enough where the following becomes practical: the length of a short section can easily be measured physically with a roller tape. If gauge and section length are known, the test set will compute cable temperature. With a short cable section, the use of a reel of jumper wire as a “Good Pair” placed above ground is now possible, instead of digging into the cable for a good one. Saves time. With a separate good pair and knowing the gauge and length of the section is the best and most accurate RFL option. In a ‘Single Pair Hookup’, the best good conductor to use is the mate of the faulted one and the next best is any good conductor from any of the adjacent pairs in the same group. Ex: If a pair has TIP(A) is faulted and RING(B) is good, RING(B) is then the best good conductor to use to shoot the fault on TIP(A). If DTF (Distance-To-Fault) and DTS (Distance-To-Strap) are equal, the fault is either at the strap or beyond.

RFL TIPS The use of a “Separate Good Pair” is always the most accurate way to locate any type of a resistance fault.

Resistance Faults GROUND : A fault between ‘Tip [A]’ and ‘Ground’, ‘Ring [B]’ and ‘Ground’ or both conductors and ‘Ground’.

Resistance Faults Cont.. SHORT : A fault between ‘Tip [A]’ and ‘Ring [B]’ conductors.

Resistance Faults Cont.. Battery CROSS : A fault between a working pair and a non-working pair (pair under test). Water -48 VDC -7 VDC Resistive Cross fault Pair # 1 - Working pair Pair # 1 - Working pair Pair # 2 - Non-working (Pair under test) -48 VDC -46 VDC Solid Cross Fault

RFL Hookup Examples Resistance Fault Locate 4-10 Press: to choose the type of hookup (single pair) or (separate good pair). Note: Defaults to the last setup. Explain: The clip and strap hookups. The user now hooks up the test set at the near end, and the strap at the far end. Press: to setup for Single Pair Hookup. 1015 Simulator: Turn Switch #3 ON; Hookup test set clips to terminal #1; Hookup Strap at terminal #5. Tip of pair 2 is Good Ring of pair 2 is faulted 10K Ohms Ground. Press: to use the setup and measure. Go to the next slide.

telephone jacketed wire “Separate Good Pair” It can be any pair of any gauge, longer or shorter than the faulted one, it doesn’t matter. For short cable section lengths (1000 feet or less), the good pair can be a reel of a CO jumper wire or a telephone jacketed wire placed above ground. Reel of CO jumper wire or telephone jacketed wire End-2 Good Pair Good Pair End-1 Faulted Pair Strap Ground Fault Near-End Shield/Ground Far-End

from another cable adjacent to the cable with the faulted pair. “Separate Good Pair” It can be any pair of any gauge, longer or shorter than the faulted one, it doesn’t matter. For long cable section lengths (several thousand feet), the good pair can come from another cable adjacent to the cable with the faulted pair. End-2 Good Pair Good Pair End-1 Strap Fault Common Faulted Pair Faulted Pair Short Near-End Far-End

How To Extend The “Far-End Strap” If Necessary Reel of CO jumper wire or telephone jacketed wire or any two wires, same length (any gauge) Good Pair [ from a distant cable ] Strap extension End-1 End-2 Far-End Strap Common Faulted Pair Short Near-End Far-End

RFL Single Section Setup Choose fault type. Choose single pair or separate pair. Select single or multiple section. Choose the gauge. Length or temperature must be “unknown.” T-G R-G Short Tip Cross Ring Cross Wet Pulp

RFL Multiple Section Setup Choose fault type. Choose single pair or separate pair. Select single or multiple section. Choose the gauge. Length or temperature must be “unknown” on last section. T-G R-G Short Tip Cross Ring Cross Wet Pulp

Estimating Cable Temperature Aerial Cable: 1. If cable is not in direct sunlight. Add 20oF to the air temperature. 2. If cable is in direct sunlight. Add 40oF to the air temperature. Buried Cable: 1. Use temperature of tap water (city water). Let water flow out of a water faucet for several minutes and then measure the temperature. 2. In cold climates, use soil temperature at cable depth.

RFL Cont.. Press setup to change section 1 from 24 awg to 26 awg. 3640.8 ft 234.8 ft 3406 ft

Distance To Strap (DTS) = 4000 feet Distance To Fault (DTF) = 2500 feet Strap To Fault (STF) = 1500 feet The bridge tap does not affect this reading. 1000 ft 3000 ft 500 ft 400 ft

Distance To Strap (DTS) = 4000 feet Distance To Fault (DTF) = 1000 feet Strap To Fault (STF) = 3000 feet Fault measures here! 1000 ft 3000 ft 500 ft 400 ft

Distance To Strap (DTS) = 3900 feet Distance To Fault (DTF) = 400 feet Strap To Fault (STF) = 3500 feet Fault measures here! 1000 ft 3000 ft 500 ft 400 ft

Questions ? Live Demo