SCHOOL BUILDING PROGRAM FOR BASIC EDUCATION (SBP4BE) DESIGNS

Slides:



Advertisements
Similar presentations
Framing.
Advertisements

Contents: Cover
The Student Handbook to T HE A PPRAISAL OF R EAL E STATE 1 Chapter 10 Improvement Analysis.
Roofs are one of a building’s primary elements and play a major part in giving a building its character. There are several different types of roof in.
Elevation Skilled & quality craftsmanship of Merlin tradition to make the complex a symbol of class. Foundation Reinforced cement.
-Master Bedroom w/ T & B - 2 Bedrooms - 1 Maids Quarter - 2 T & B - Living Room - Dining Room - Porch - Terrace - Carport -Standard Lot Area – 156 sqm.
KCDC Knox County Development Corporation Virtual Building 50,000 SF Manufacturing- 4,300 SF office building.
Finishes many options Walls wood shakes, shingles, board & batten (vertical), plank lap (horizontal), T1-11 ply, vinyl, fiber cement, aluminum, stucco.&
“Sustainable Building Systems and Construction For Designers” Chapter 7: Walls.
Chapter 16 Floor Plan Symbols.
Miscellaneous Details. u May have special or unusual conditions –inside or outside structure u Approach same as before –analysis of how specific detail.
Civil Engineering & Architecture 2.3 Residential Design.
Chapter 14 Floor-Plan Symbols.
EXTERIORS FOR WOOD LIGHT FRAME CONSTRUCTION
Class Day Seventeen.
© 2006 ITT Educational Services Inc. CD230 Architectural Design & Drafting: Unit 1 Slide 1 Unit 1 CADD Part III.
Elevations.
Blue Prints.
LOGO General Trias Cavite. Along cross roads of Daang Hari and Arnaldo Hi-way.
Experience the verve of living by the banks and drift through the historic and scenic beauty of Pasig River. Project lot area composed of 14,000 square.
BUILDING CONSTRUCTION V ARCHITECTURAL FINISHING SYSTEMS
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Construction Residential Houses Definition of a House: A structure serving as a dwelling for one or more persons, especially for a family.
The Student Handbook to T HE A PPRAISAL OF R EAL E STATE 1 Chapter 11 Improvement Analysis.
Building Codes and Interior Design
Elevations, Layout and Drawing Technique.
Chapter 35 Section Layout.
© 2006 ITT Educational Services Inc. CD230 Architectural Design & Drafting: Unit 10 Slide 1 Unit 10 Commercial Construction.
Wall and Ceiling Construction
Chapter 23 Plumbing Systems. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Identify several.
© 2010 Delmar, Cengage Learning Instructor Resources for Lesson C Material Basics.
Finishing the Building
Construction Drawings
Code Analysis. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the NFPA)  Mechanical, electrical.
HOME MODEL. P e r s p e c t i v e HOME MODEL 4.00m X 5.50m Floor Area = 22 sqm. Turn-over unit 4.00m 5.50m 1.4m 4.00m.
EDT Cabin Design Project - Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300 Kenneth Fitzpatrick, P.E.
Picking up from last week…. Fire stair layout Fire stair layout Due October 18 th Due October 18 th Assignment #1.
FLOOR PLANS WHERE IT ALL BEGINS. FLOOR PLANS 1.Column Grids Backbone of all the documents, especially the floor plans Alpha characters horizontal Numeric.
Design Development Code analysis Partition types.
CTRA Green Features. 1. Green Roof 2. Hot Water Solar Heaters These are a type of solar panel. It is called evacuated tube collectors and they heat our.
QuickWalls® strong. fast. simple. *Light Weight *Insulated
Introduction to Plan of a building Instructor Engr Kamran Khan Department of civil engineering City University Peshawar.
(ACCESSIBILITY LAW) MINIMUM REQUIREMENTS FOR ACCESSIBILITY
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Drafting 2 (Arch) Quiz Review #6 Quiz Review. 1.To anchor a stud wall to the subfloor, carpenters nail through the: Sole plate Header Jamb Joists Quiz.
Shree Chand Homes Presents GOLF VIEW HOMES Situated at Greater Noida, Dadri Road next to Ansal’s Golf Link II a very close location From proposed Metro.
Mayor’s Office on Disability City and County of San Francisco Discussion of Common Design and Construction Errors.
3’ door 32 ‘ 14 ‘ 18 ‘ Rear ramp door 8’4” 3’ x 16’ slide out 3’ x 10’ slide out 3 ‘ 8 ‘ 12 ‘ FRONT Top View Dimensions.
Drafting 2 (Arch) Quiz Review #3 Quiz Review. 1.Dashed lines that follow the counters in a kitchen floor plan most likely represent: A dishwasher Upper.
Rosemead.
THIS IS JEOPARDY.
An-Najah National University Secondary School Design
How Completed Interiors Are Achieved: Designing & Building
* 07/16/96 Site Development Plan * ##.
Table (3.1)- the averages of the 10 models costs
Building Structural Systems
6.02 Recognize components of construction
Wood Structures Topic 8 Quality Workmanship
MATERIALS AND CONSTRUCTION I
FLOATING STUDENT RESIDENCE
Pre-Contract Cost Control
ISA Prime Developments
WHERE IT ALL BEGINS.
Arch205 building construction wall systems
Q:\Pictures\Industrial\NWQ\Crescent IV\Crescent IV - pic for flyer.jpg
Week 5 Drafting and Dimensioning the Architectural Floor Plan.
Building standards Mr. Da Silva.
© OnCourse Learning.
Elevations, Layout and Drawing Technique.
LIFT,ESCALATOR AND MOVING WALKS
Presentation transcript:

SCHOOL BUILDING PROGRAM FOR BASIC EDUCATION (SBP4BE) DESIGNS

DESIGN CONSIDERATIONS Factors affecting the physical condition of the students; a. temperature & air quality b. noise level (external & internal) c. colour schemes d. space in classroom

DESIGN CONSIDERATIONS Function and needs of its user Economy in construction, utilization and maintenance Human dimensions Design codes and Specifications

BASIC FEATURES : SINGLE STOREY FOUR (4)-CLASSROOM SCHOOL BUILDING DESIGN

BASIC FEATURES : SINGLE STOREY FOUR (4)-CLASSROOM A. Basic Structure Reinforced concrete B. Column Schedules 200mm x 300mm – COLUMN SIZE B. Roof Framing Steel Rafters and Purlin C. Exterior Finish 1. Roof 0.40mm PRE-PAINTED LONGSPAN Corrugated G.I. Sheet 2. Eaves With Exterior Ceiling 3. Walls 6” CHB with plain cement plaster paint finish 4. Windows Clear Glass Jalousie blades On a Shutter-type windows 5. Doors Panel Doors

BASIC FEATURES : SINGLE STOREY FOUR (4)-CLASSROOM D. Interior Finish 1. Flooring Reinforced concrete slab with plain cement finish 2. Ceiling ¼” thk Ordinary Plywood 3. Partition 6” CHB with plain cement plaster paint finish E. Electrical Provisions Complete with basic lighting fixtures and outlets F. OTHERS With Blackboards as specified 1. Ceiling Vents dimension 2 - 9000mm X 275mm req’d area for 1 classroom

SPECIAL FEATURES :: TOILET ATTACHED Can accommodate male students (2-water closet & 2- urinals) female students (2-water closet) Handwashing facilities (2-units of faucet per toilet) Provision of toilet for persons with disabilty (1-water closet, 1-lavatory w/ complete accesories Provision of ramp for persons with disability (PWD) WINDOW SECURITY GRILLS Provision of grills in all classroom windows WATER SUPPLY Provision of cistern tank

TWO STOREY FOUR (4)-CLASSROOM SCHOOL BUILDING DESIGN

BASIC FEATURES : TWO STOREY FOUR (4)-CLASSROOM A. Basic Structure Reinforced concrete B. Roof Framing Steel Trusses and Purlins C. Exterior Finish 1. Roof 0.40mm PRE-PAINTED LONGSPAN CORR. G.I. ROOFING SHEET 2. Eaves With Exterior Ceiling 3. Walls 6” CHB with plain cement plaster paint finish 4. Windows Clear Glass Jalousie blades on a “Shutter-type” Windows 5. Doors PANEL Doors (for Classrooms) FLUSH Doors (for Toilets) D. Interior Finish 1. Flooring Reinforced concrete slab with plain cement finish 2. Ceiling ¼” (6mm) thk Ordinary Plywood 3. Interior Wall Finish Plain cement plaster paint finish E. Electrical Provisions Complete with basic lighting fixtures and outlets

SPECIAL FEATURES :: TOILET ATTACHED PROVISION OF TOILETS EVERY FLOOR Can accommodate male students (2-water closet & Urinal Trough) female students (2-water closet) Handwashing facilities (2-units of faucet per toilet) Provision of toilet for persons with disabilty (1-water closet, 1-lavatory w/ complete accesories Provision of ramp for persons with disability (PWD) WINDOW SECURITY GRILLS Provision of grills in all classroom windows WATER SUPPLY Provision of cistern tank SERVICE STAIRCASE/EMERGENCY EGRESS/FIRE EXIT Provision of Fire exit in compliance with B.P. 344 “Accessibility Law”

CROSS SECTION

WINDOW & DOOR DETAIL @ END WALL 900mm

WINDOW & DOOR DETAIL @ MID-SPAN WALL 900mm

WINDOW SCHEDULE DETAIL

TOILET LAYOUT FOR PERSONS WITH DISSABILITY

TOILET LAYOUT FOR PERSONS WITH DISSABILITY (PWD)

SINGLE STOREY FOUR (4)-CLASSROOM

TWO STOREY FOUR (4)-CLASSROOM

DepEd COLOR SCHEME A. ELEMENT B. MASONRY PAINT (LATEX) C. QUICK-DRY ENAMEL (QDE) PAINT FOR WOOD, METAL, etc. 1. Roofing & Accessories (if introduced) Reference: PANTONE* Color System (Paints + Interiors) Foam Green 14-0115 TPX 2. Doors QDE Palmyra Green DepEd SCRF-11-00911 3. Column & Beams MCS Columns Beige DepEd SCRF-11-00911 (Light shade) QDE Columns Beige DepEd SCRF-11-00911 (Light shade) 4. Exterior Wall MCS Exterior Beige DepEd SCRF-11-00911 (very light shade) QDE Exterior Beige DepEd SCRF-11-00911 (Very Light shade) 5. Interior Wall MCS Interior Beige DepEd SCRF-11-00911 (lightest shade) QDE Exterior Beige DepEd SCRF-11-00911 (Lightest shade) 6. Ceiling (suspended or slab/stairslab soffit) Flat White Latex DepEd SCRF-11-00911

DepEd MINIMUM PERFORMANCE STANDARD AND SPECIFICATIONS (MPSS)

DepEd Minimum Performance Standard and Specifications (MPSS) PURPOSE: To Establish the minimum requirements To conform with in the design and construction

The design proposals shall governed by the following: A. Design Codes and Specifications : Architectural Design, Structural Design, Electrical Design, Sanitary and Plumbing Design B. Architectural Design Standards: Classroom size Windows Doors Floors Ceiling Roof Partitions Corridor Chalkboard Painting

C. Structural Design Standards D. Electrical Design Standards E. Sanitary and Plumbing Design Standards F. Toilets G. Materials Reinforced Concrete Structural Steel Protection from Heat Resistance to Termites Protection from Corrosion Resistance to Fire Noise Level Limit Protection from Toxicity H. Design Standard for Furniture

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO Classroom Size The size of the classroom for elementary and secondary schools must be 7 meters (m) in width/depth x 9 m in length measured from the centers of the walls Floor The floor must be of non-skid finish. The finished floor line (FFL) should be higher than the corridor by 25 mm. The first floor finish elevation of the corridor must be above the level of flood indicated/ identified in the Site Appraisal Reports (SAR) PLUS 0.20 m (8 iches).

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO Roof and Roof Cavity 0.40mm thk. Pre-painted longspan corr. roofing sheet The minimum horizontal clear length of eaves (excluding gutter, if introduced) shall be: front = 1.50 m; rear = 1.10 m; and sides = 0.6 m i.e. no interior gutter. For the 2-storey building, maintenance access to the roof cavity must be through the corridor.

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO WINDOWS Shutter Type window (“Jalou-Plas” or equivalent)

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO DOORS Keyed Lever Type Locksets (“Creston”, “Sobo”, “EZ Set”, “Guli”) Panel door type

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO DOORS Keyed Lever Type Locksets (“Creston”, “Sobo”, “EZ Set”, “Guli”) Panel door type

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO CHALCKBOARDS The classroom must be provided with a built-in curved chalkboard measuring 4.88 m wide by 1.22 m tall with thicknesses of 0.13 m at center and 0.42 m at the 2 ends, with mounting heights and material and finish specifications as per DepED standard.

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO CIRCULATION & EMERGENCY EGREES CORRIDOR The minimum single-load corridor clear width shall be 2.50 m for all school building types The fire exit ladders shall have a minimum clear width of 0.6 m

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO ELECTRICAL WORKS Industrial Type Lighting with Bracket (Single Storey) Replace Incandescent with CFL Bulbs PVc Pipe Conduits (not Flexible Hose) All wires are Stranded Type T5 28w Flourescent Bulb (option for Ord. 40w Flourescent Bulb) With Ceiling Fan

EXISTING DEPED STANDRAD SPECIFICATIONS MINIMUM PERFORMANCE STANDARD & SPECIFICATIONS (MPSS) ACTUAL PHOTO PLUMBING WORKS Waterline piping system   The system must be according to E DIN1988 for Polypropylene Random Copolymer (PP-R) type 3 pipe and ASTM A53/A53M. The system must provide for a waterline service entrance. PPR PN16 (COLD) PPR PN20 (HOT)

END OF PRESENTATION…….