Drafting 2 (Arch) Quiz Review #3 Quiz Review. 1.Dashed lines that follow the counters in a kitchen floor plan most likely represent: A dishwasher Upper.

Similar presentations


Presentation on theme: "Drafting 2 (Arch) Quiz Review #3 Quiz Review. 1.Dashed lines that follow the counters in a kitchen floor plan most likely represent: A dishwasher Upper."— Presentation transcript:

1 Drafting 2 (Arch) Quiz Review #3 Quiz Review

2 1.Dashed lines that follow the counters in a kitchen floor plan most likely represent: A dishwasher Upper (wall hung) cabinets A trash compactor A valance Quiz Review #3

3 1.Dashed lines that follow the counters in a kitchen floor plan most likely represent: A dishwasher Upper (wall hung) cabinets A trash compactor A valance Quiz Review #3

4 2. What BEST describes the split-wired duplex receptacle outlet symbol? Circle with one line Circle with two lines Circle with two lines and one side shaded Circle with one line and one line shaded Quiz Review #3

5 2. What BEST describes the split-wired duplex receptacle outlet symbol? Circle with one line Circle with two lines Circle with two lines and one side shaded Circle with one line and one line shaded Quiz Review #3

6 3. Which plan would include illustrations for distribution panel, meter, and lighting outlets? Floor plan Elevation plan Electrical plan Circuit plan Quiz Review #3

7 3. Which plan would include illustrations for distribution panel, meter, and lighting outlets? Floor plan Elevation plan Electrical plan Circuit plan Quiz Review #3

8 4. How much voltage is required to operate a dishwasher? 60 volts 100 volts 120 volts 240 volts Quiz Review #3

9 4. How much voltage is required to operate a dishwasher? 60 volts 100 volts 120 volts 240 volts Quiz Review #3

10 5. A duplex convenience outlet should be located on any wall longer than: 1’ – 0” 2’ – 0” 4’ – 0” 5’ – 0” Quiz Review #3

11 5. A duplex convenience outlet should be located on any wall longer than: 1’ – 0” 2’ – 0” 4’ – 0” 5’ – 0” Quiz Review #3

12 6. What is the most logical place for a 3-way switch? Bathroom Hall Closet Office Quiz Review #3

13 6. What is the most logical place for a 3-way switch? Bathroom Hall Closet Office Quiz Review #3

14 7. How many switches are required for a stairway between main levels of a home? Two three-way switches Two single-pole switches Three single-pole switches One three-way switch Quiz Review #3

15 7. How many switches are required for a stairway between main levels of a home? Two three-way switches Two single-pole switches Three single-pole switches One three-way switch Quiz Review #3

16 8. Where are weatherproof outlets usually installed? Bathroom Bedroom Kitchen Exterior of a home Quiz Review #3

17 8. Where are weatherproof outlets usually installed? Bathroom Bedroom Kitchen Exterior of a home Quiz Review #3

18 9. Which type of outlet should be installed in bathrooms and other wet areas? Duplex convenience Ground Fault Interrupt Special Purpose Weather Resistant Quiz Review #3

19 9. Which type of outlet should be installed in bathrooms and other wet areas? Duplex convenience Ground Fault Interrupt Special Purpose Weather Resistant Quiz Review #3

20 10. Which statement best describes the placement of symbols on an electrical fixture plan? Layer color should be blue Total circuit load must be noted Approximate locations are used Locations are dimensioned Quiz Review #3

21 10. Which statement best describes the placement of symbols on an electrical fixture plan? Layer color should be blue Total circuit load must be noted Approximate locations are used Locations are dimensioned Quiz Review #3

22 11. To create a clear electrical plan, on which plan should electrical symbols be placed? Framing plan Floor plan with dimensions Floor plan without dimensions Elevation plan Quiz Review #3

23 11. To create a clear electrical plan, on which plan should electrical symbols be placed? Framing plan Floor plan with dimensions Floor plan without dimensions Elevation plan Quiz Review #3

24 12. How many feet apart should outlets be spaced for small appliances in the kitchen? 2’ 4’ 6’ 8’ Quiz Review #3

25 12. How many feet apart should outlets be spaced for small appliances in the kitchen? 2’ 4’ 6’ 8’ Quiz Review #3

26 13. What voltage rating is needed for a refrigerator outlet? 60 volts 100 volts 120 volts 240 volts Quiz Review #3

27 13. What voltage rating is needed for a refrigerator outlet? 60 volts 100 volts 120 volts 240 volts Quiz Review #3

28 14. What is the recommended distance for the service conductors to run inside the house before they reach the main disconnect switch? 10’ – 0” 12’ – 0” 20’ – 0” 22’ – 0” Quiz Review #3

29 14. What is the recommended distance for the service conductors to run inside the house before they reach the main disconnect switch? 10’ – 0” 12’ – 0” 20’ – 0” 22’ – 0” Quiz Review #3

30 15. What is the purpose of a legend on an Electrical Plan? Show HVAC placement Specify wire sizes Define edges of work space Explain symbols Quiz Review #3

31 15. What is the purpose of a legend on an Electrical Plan? Show HVAC placement Specify wire sizes Define edges of work space Explain symbols Quiz Review #3

32 16. Where should switches that operate a closet light be located? Inside the closet Near the night stand In the hallway Outside the closet Quiz Review #3

33 16. Where should switches that operate a closet light be located? Inside the closet Near the night stand In the hallway Outside the closet Quiz Review #3

34 17. What voltage is required by a clothes dryer? 60 volts 120 volts 220 volts 300 volts Quiz Review #3

35 17. What voltage is required by a clothes dryer? 60 volts 120 volts 220 volts 300 volts Quiz Review #3

36 18. What area of the home would usually NOT require three-way switches? Garage Bathroom Hall Stairs Quiz Review #3

37 18. What area of the home would usually NOT require three-way switches? Garage Bathroom Hall Stairs Quiz Review #3

38 19. Where should the switch for the main source of light for a room be located? Latch side of the entrance door Hinged side of the entrance door Either side of the entrance door Minimum of five feet from the door Quiz Review #3

39 19. Where should the switch for the main source of light for a room be located? Latch side of the entrance door Hinged side of the entrance door Either side of the entrance door Minimum of five feet from the door Quiz Review #3

40 20. Which appliance is MOST likely to require an independent (220volt) circuit? Clothes Washer Fan Range Dishwasher Quiz Review #3

41 20. Which appliance is MOST likely to require an independent (220volt) circuit? Clothes Washer Fan Range Dishwasher Quiz Review #3

42 21. A sectional drawing of a building is a/an: Elevation Site plan Floor plan Schedule Quiz Review #3

43 21. A sectional drawing of a building is a/an: Elevation Site plan Floor plan Schedule Quiz Review #3

44 22. The "scale" selected to create a drawing depends upon: The available paper size The size of the overall structure The architect’s preference The size of the structure and plot size Quiz Review #3

45 22. The "scale" selected to create a drawing depends upon: The available paper size The size of the overall structure The architect’s preference The size of the structure and plot size Quiz Review #3

46 23. What is the purpose of annotation on a drawing? Clarify what a symbol represents Identify where the material symbol is produced Identify the draftsman designing the symbols on drawings Identify dimensions that are needed to size the floor plan symbols Quiz Review #3

47 23. What is the purpose of annotation on a drawing? Clarify what a symbol represents Identify where the material symbol is produced Identify the draftsman designing the symbols on drawings Identify dimensions that are needed to size the floor plan symbols Quiz Review #3

48 24. How are ceiling joists often noted on a floor plan? A line with arrowheads indicating direction Hidden lines A framing chart reference symbol A series of equally spaced, parallel lines Quiz Review #3

49 24. How are ceiling joists often noted on a floor plan? A line with arrowheads indicating direction Hidden lines A framing chart reference symbol A series of equally spaced, parallel lines Quiz Review #3

50 25. Which statement is correct concerning floor plan drawings? Dimension lines are broken, and the number placed inside the break Dimension lines are read only from the bottom of the page (unidirectional dimensioning) Dimension chains should be added and compared against the overall dimension Room names are not given Quiz Review #3

51 25. Which statement is correct concerning floor plan drawings? Dimension lines are broken, and the number placed inside the break Dimension lines are read only from the bottom of the page (unidirectional dimensioning) Dimension chains should be added and compared against the overall dimension Room names are not given Quiz Review #3

52 26. The outer dimension lines on a floor plan should dimension: The building offsets Center lines of vents The door and window locations The overall width and depth of the structure Quiz Review #3

53 26. The outer dimension lines on a floor plan should dimension: The building offsets Center lines of vents The door and window locations The overall width and depth of the structure Quiz Review #3

54 27. What is the most popular scale for residential floor plan drawings? 1/8” = 1’-0” ¼” = 1’-0” ½” = 1’-0” 1” = 1’-0” Quiz Review #3

55 27. What is the most popular scale for residential floor plan drawings? 1/8” = 1’-0” ¼” = 1’-0” ½” = 1’-0” 1” = 1’-0” Quiz Review #3

56 28. What is the accepted method of writing a measurement of "six-inches" on an architectural drawing? 6” 0’-6” ½’.5’ Quiz Review #3

57 28. What is the accepted method of writing a measurement of "six-inches" on an architectural drawing? 6” 0’-6” ½’.5’ Quiz Review #3

58 29. Which of the following statements is TRUE concerning a floor plan drawing? All dimensions are written so that they can be read from the bottom of the page Dimensions are written so that they can be read from the bottom and right side of the page Dimensions under four feet are converted to inches. For example, a two foot distance would be written as 24” Dimensions are placed so that they can be read from the bottom and left side of the page Quiz Review #3

59 29. Which of the following statements is TRUE concerning a floor plan drawing? All dimensions are written so that they can be read from the bottom of the page Dimensions are written so that they can be read from the bottom and right side of the page Dimensions under four feet are converted to inches. For example, a two foot distance would be written as 24” Dimensions are placed so that they can be read from the bottom and left side of the page Quiz Review #3

60 30. Where are overall building dimensions placed? Inside other dimensions On all four sides of a floor plan Outside the other dimensions Closest to the building Quiz Review #3

61 30. Where are overall building dimensions placed? Inside other dimensions On all four sides of a floor plan Outside the other dimensions Closest to the building Quiz Review #3

62 31. When dimensioning architectural plans, which is the symbol for a "foot" measurement? ‘ “ Ft. * Quiz Review #3

63 31. When dimensioning architectural plans, which is the symbol for a "foot" measurement? ‘ “ Ft. * Quiz Review #3

64 32. Which of the following would be located on an architect's scale? ¼” – 1’-0” 1” – 20-0” 1cm = 10mm 1/16” – 1’-0” Quiz Review #3

65 32. Which of the following would be located on an architect's scale? ¼” – 1’-0” 1” – 20-0” 1cm = 10mm 1/16” – 1’-0” Quiz Review #3

66 33. What is the dimensioning system most commonly used in architectural drafting? Architectural dimensioning Aligned dimensioned Construction dimensioning Unidirectional dimensioning Quiz Review #3

67 33. What is the dimensioning system most commonly used in architectural drafting? Architectural dimensioning Aligned dimensioned Construction dimensioning Unidirectional dimensioning Quiz Review #3

68 34. Which of the definitions below defines piers? Horizontal members used to support the ends of floor joists Horizontal members used to support walls Vertical members used to support floor systems Vertical members used to support roof structures Quiz Review #3

69 34. Which of the definitions below defines piers? Horizontal members used to support the ends of floor joists Horizontal members used to support walls Vertical members used to support floor systems Vertical members used to support roof structures Quiz Review #3

70 35. What is the masonry vertical post used to support the floor systems known as? Lally column Lintel Pier Wall stud Quiz Review #3

71 35. What is the masonry vertical post used to support the floor systems known as? Lally column Lintel Pier Wall stud Quiz Review #3

72 36. Which of the definitions below defines live loads? Fixed or moving weights that are not a part of the structure Framing materials both vertical and horizontal types Fixed weights that are part of the structure Weights of more that 500 lbs/sq.ft. Quiz Review #3

73 36. Which of the definitions below defines live loads? Fixed or moving weights that are not a part of the structure Framing materials both vertical and horizontal types Fixed weights that are part of the structure Weights of more that 500 lbs/sq.ft. Quiz Review #3

74 37. Which of the definitions below defines "Drain tile"? Black plastic with holes on half of its circumference Red clay put together with short spaces between the sections Black cast iron put together with bells White PVC with no holes or spaces Quiz Review #3

75 37. Which of the definitions below defines "Drain tile"? Black plastic with holes on half of its circumference Red clay put together with short spaces between the sections Black cast iron put together with bells White PVC with no holes or spaces Quiz Review #3