Condensate Trap Heater KGAHT0201KIT 2013 Fall Zone Meeting Gary Georgette/Jerry Shipman UTC Climate, Controls & Security Confidential and Proprietary Information.

Slides:



Advertisements
Similar presentations
Basic Electricity.
Advertisements

Electricity Lesson II Electrical Symbols EE.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
Thermostats. I would recommend that as you proceed through this power point presentation that you refer to your textbook, Unit 14, for some great visuals.
HEAT PUMPS.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
AC-SSC-1 Installation and operation manual
Distributor Technical Training
Insert White, Black and Yellow Wires into Switch Terminals as Shown.
Installation. Indoor Unit Installation Typical Installation.
Air-Conditioning Control Systems
Dishwasher Rework. Identify Unit Disconnect Power Turn off Breaker… … or unplug power cord.
© 2006 Cisco Systems, Inc. All rights reserved.Cisco Confidential Steelers Mechanical Design Review 1 PLC MODULE INSTALLATION INSTRUCTIONS IN CGR1240.
Electrical wiring Household skills. Power Grid All electrical devices in your home are physically connected to a power generating facility You will not.
S8610U3009 Universal Electronic Ignition Modules Training Module (plus Universal Retrofit Kits Y8610U4001 and Y8610U6006)
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
We Design Innovative Bus Interiors LED Retrofit Systems Designed ForPretoria Hadley/Transmatic L-20 and Hadley/Transmatic L-20 Fluorescent Aisle Lighting.
S8910U1000 Universal Electronic Ignition Modules Training Module
DC234KL Dust Extraction Adaptor rebuild Reason for change –In 2010 a cordless dust extraction unit was brought to the market. –When connecting the cordless.
How to Construct a Robot Part 7: Wiring and Controller Installation Copyright © Texas Education Agency, All rights reserved. 1.
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
American Electrical, Inc. Junction Box / Hookup Box Fast and easy way to make electrical connections An assembled kit – no need to procure and assemble.
EET Survey of Electronics
Electrical Power Systems
Installation. Indoor Unit Installation Typical Installation.
Residential Wiring Facts
ST9120U1003 Universal Electronic Fan Timer Training Module
S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
UTC Climate | Controls | Security Confidential and Proprietary Information Not for Further Distribution Lt. Commercial Product Updates 2013 Zone Service.
E2 Motors and Motor Starting
Title: Corvette C5 Column Lock Bypass Originator: John Neese Date: 30 Jan 2005 Revision: Sheet: 1 of 6 Column Lock Bypass.
RESIDENTIAL AIR HANDLERS
Installation. Indoor Unit Installation Typical Installation.
Dan Arnold, Sr. Eng. Director, Cooling Systems Split Systems Update.
Installation of Gil’s Fuel Box By Albert “ARAMP1” Rampone.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Eco-Winter Installation. – Step 1 – Mount Eco-bypass to water heater.
2G BBULBE PASS Instructions-5 Replacement of Heater.
Insert White, Black and Yellow Wires into Switch Terminals as Shown Rotate Switch to Bend Wires. The Wires Should be Bent as Close to the Terminal End.
Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox LEAD SPLICE SPECIFICATION  BY: ROY HANNAFORD.
E4 HVACR Electrical Installation
Tools used in this demonstration include: Flathead Screwdriver Wire Cutters.
 E4 HVACR Electrical Installation #3 Circuit breakers, disconnects, and fuses.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
W. C. “Buster” Hounshell Spring 2002 SWITCHES.
BASIC ELECTRICITY AND MAGNETISM
Installing Branch Circuits Unit #32. What are Wiring Boxes? hold cable or conduit and protect connections attached to building contain all electrical.
© 2015 Eaton. All Rights Reserved.. Eaton 1000/1800W True Sine Wave Inverter Aftermarket Installation Instructions 8/01/2016.
Lighting Retrofit Assembly (LRA)
New Low Capacity Gas Furnace
This picture shows what the wiring of a new alternator looks like
X-Spot Lamp Socket Replacement Procedure
E4 HVACR Electrical Installation
E4 HVACR Electrical Installation
ASSEMBLY/INSTALLATION INSTRUCTIONS ASSEMBLY AND INSTALLATION
RESIDENTIAL CONDENSING GAS FURNACES Vent Design & Installation Training Spring 2014 UTC Building & Industrial Systems Confidential and Proprietary Information.
Controller Rework.
SWITCHES W. C. “Buster” Hounshell Spring 2002.
NEC Wiring Diagrams.
A-90 Pressure Switches 2013 TSA Meeting
S8910U1000 Universal Electronic Ignition Modules Training Module
Piping Flow Maintenance
Which of the following would best describe the situation inside the circle?
A. Touching both terminals with the hands can cause electrical shock
ST9120U1003 Universal Electronic Fan Timer Training Module
Reader Swap out Guide.
Relocating a Three Phase Transformer Bank
Replacing TrueAir Thermostat with Ecobee SI
Relocating a Three Phase Transformer Bank
Presentation transcript:

Condensate Trap Heater KGAHT0201KIT 2013 Fall Zone Meeting Gary Georgette/Jerry Shipman UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

KGAHT0201CFP Kit Contents: –Condensate trap with heat pad installed Includes: Low voltage harness External thermostat –115 VAC to 24 VAC Step-down transformer –Trap grommet Horizontal direct vent installations –7/8-in. casing knockout grommet UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Kit Contents-Trap Heater Heat pad is factory-applied and wraps around the entire trap assembly External thermostat Low voltage harness & transformer leads UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Kit Contents-Transformer 115 VAC, Neutral & Ground Leads UL Label Mounting Screw Low Voltage Screw Terminals UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Kit Contents-Grommets Trap Grommet 7/8-in. Casing Knockout Grommets UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Basic Wiring Diagram UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Basic Installation Remove factory trap from furnace Install trap from kit on furnace Remove (2) 7/8-in. knockouts on same side of furnace Install transformer from kit on field-supplied J-box Mount J-box to knockout on furnace casing Install 7/8-in. grommet through knockout for J- box/furnace casing UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Basic Installation Route external 115 VAC power leads and furnace power leads to J-box –Use external disconnect when required by code Connect external, furnace and transformer leads together Install 7/8-in. grommet in other 7/8-in. knockout in casing Route trap heater leads under inducer assembly and through that grommet in casing Verify trap heater leads are not touching hot surfaces Connect low voltage leads to screw terminals on transformer UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Trap Heater Installed UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

External Connections Low Voltage Leads & Casing Grommet Furnace Line Voltage Power Leads & Casing Grommet Secure Excess Wire & Connect to Transformer Complete Line Voltage Connections In J Box UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution

Conclusion It’s quick It’s easy Instructions on HVACpartners –AG-KGAHT-01 Questions? UTC Climate, Controls & Security Confidential and Proprietary Information - Not for Further Distribution