1 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox LEAD SPLICE SPECIFICATION  BY: ROY HANNAFORD

2 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead SOLDER BOX MOUNTING PLATE 7500 AMP.

3 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead  ROUTING AND BEND RADIUS FOR CABLE.

4 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead  Layout with four cables in solder box.

5 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead  Assemble cables and solder in box.

6 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead  Place aluminum push block over the top piece of conductor.

7 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead  Install top plate to hold tension while soldering.

8 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead  Insert cartridge heater and heat joint to 240 C and tighten clamp bolts.

9 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 7500 Amp HTS Lead  Clean joint install voltage taps and insulate cables.

10 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 600 /120 Amp Lead  Remove Kapton insulation and prep joint for soldering.

11 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 600 /120 Amp Lead  Tin wire and insert into solder fixture.

12 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 600 /120 Amp Lead  Assemble wire and lead into solder fixture.

13 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 600 /120 Amp Lead  Install solder fixture top plate.

14 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 600 /120 Amp Lead  Insert cartridge heater and heat joint to 240 C, tighten screws on fixture.

15 Roy Hannaford October 23-24, 2002 RFP Review DFBX Feedbox 600 /120 Amp Lead  Clean joint install voltage taps and insulate wire.