CELEBRATING 30 YEARS OF ENERGY SAVINGS LUBRICATION ENHANCEMENT SYSTEM.

Slides:



Advertisements
Similar presentations
Presented by Paul Almond – Datacentre UK
Advertisements

TORO ID PRE COOLER (Patent Pending) for Air Cooled Condensers Improving Cooling Efficiency and Energy Conservation in Air Cooled HVAC Systems.
Basic Refrigeration, Its Components, and Its Cycle
ROOM AIR CONDITIONERS ENERGY STAR ® SALES ASSOCIATE TRAINING.
Green Datacenters solution March 17, 2009 By: Sanjay Sharma.
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Chill Out With MaxR100™! AllGard Surface Care LLC
North American Mechanical Inc. School District of Cambridge A Business Relationship Presentation Use our energy to save yours®
Baking Oven Chain Lubrication. Bakeries produce thousands of loaves, buns, pitas, pies per day. HOT Issues High Temperatures Clean Conditions Washdown.
A passive investment towards improved control over energy costs.
Refrigerant Line Sizing Knowledge makes the professional DESIGN AIR UNIVERSITY.
P1 Revision Examination Style Questions
The Thermodynamic Principles Liquid Pressure Amplification
Thermal Energy and Heat
The BallTech ® System Energy saving opportunity for water-cooled chillers.
REFRIGERATION Refrigeration may be defined as the process of removing heat from a substance under controlled conditions and reducing and maintaining the.
Fishbeck, Thompson, Carr & Huber, Inc. Application of High-Speed Turbocompressors at Municipal WWTPs in Michigan Jim Flamming, P.E., Senior Process Engineer,
Education at your fingertips
Profitable Group – Strategic Global Investment Exclusive distributor of all Boron-CLS-Bond™ products in UK, Asia, Australasia, Balkans Crosses the last.
K&W Permanent Metallic ® Block Seal
1.1 INFRARED RADIATION 1.2 SURFACES AND RADIATION 1.3 STATES OF MATTER 1.4 CONDUCTION 1.5 CONVECTION 1.6 EVAPORATION AND CONDENSATION 1.7 ENERGY TRANSFER.
HVAC & Refrigeration Restoration and Efficiency ©2011 Trans Bio Energy, LLC. All rights reserved. Do not reproduce, reuse or distribute without permission.
Basic Refrigeration Cycle
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
JET PROPULSION Part 5 Jet Engine Operation Oil Systems.
Chapter 9: Water Heating To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Cold-Plus™ Refrigerant Enhancer
ELECTRIC HYBRID HEAT PUMP WATER HEATERS
Presents. Solid Start The Solid Start family began developing and manufacturing maintenance chemicals in 1976 for: –Automotive –Racing –Heavy industry.
Lubrication is the lifeblood of industry Protect your priceless assets … … AMP UP TODAY! Lubrication of the future … today! AMP Advanced Maintenance Program.
POWER CONTROL LIMITED Introducing “PermaFrost” Presented by Ir. K.M. Wong.
Engine Friction Dr Jehad Yamin.
Cold-Plus™ Refrigerant Enhancer
Cold-Plus™ by TRIFECTA DISTRIBUTORS LLC
PRESENTED BY Toshiba International: Mike Tharp Hupp Electric Motors: Dave Patterson.
STEAM HEATING.
Science project By Dillon Williams And. Vocab Section 1 - Temperature of an object is a measure of the average kenetic energy of the particles in the.
Muhajir Ab. Rahim School of Mechatronic Engineering
1 Basics of Heating and Air Conditioning Heat energy Heat measurement Heat movement States of matter Latent and sensible heat Boiling points Pressures-
The High Cost of CONTAMINATION Oil Contaminated Refrigerant costs you MONEY in more ways one! in more ways than one!
THE QUANTITY OF HEAT   The thermal energy lost or gained by objects is called heat. One calorie (cal) is the quantity of heat required to change the temperature.
Introduction Topic: The Basic Ground Source Heat Pump Name: Matthew Stoangi Objective: To provide a clear understanding of the mechanics involved in the.
Unique & Superior Lubrication Technologies
OVER 20 YEARS OF ENERGY SAVINGS FRIGI-TECH REFRIGERANT OIL ADDITIVE Frigi-Tech International, Inc Prairie Wind Lane,. Houston, Texas T:
Section 1 Temperature and Heat. Kinetic Theory  All objects (even people) are made of particles and atoms that constantly and randomly move. All atoms.
RESTORES, RECONDTIONS AND MAINTAINS THE EFFICIENCY OF A 23 YEAR OLD AIR CONDITIONING UNIT METROPOLITAN WASHINGTON COUNCIL of GOVERNMENTS METROPOLITAN WASHINGTON.
BCWC Water-cooled water chillers with centrifugal compressor/s
Physics Review for the GHSGT. Types of energy Solar Electrical Nuclear Chemical Mechanical Potential Kinetic.
1-1-Why Maintenance HVAC ? Increases equipment life & reliability Reduces size & scale & number of repairs Lowers maintenance costs through better.
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
HEATING AND COOLING SYSTEMS
President UniversityErwin SitompulThermal Physics 10/1 Lecture 10 Thermal Physics Dr.-Ing. Erwin Sitompul President University
Introduction to Energy Management. Week/Lesson 9 part a Evaporative Cooling and Cooling Towers.
Heat Engines A gasoline engine is a form of a heat engine, e.g. a 4-stroke engine INTAKE stroke: the piston descends from the top to the bottom of the.
Refrigeration Systems
REFRIGERATION Refrigeration is a process in which work is done to move heat from one location to another. Uses of Refrigeration :  Industrial uses 
Air condition installation
Refrigeration.
GROUND SERVICING OF VARIOUS SUB SYSTEMS
. Level 3 Air Conditioning Inspections for Buildings
Chapter: 06 The Second Law.
Optimum Pump Performance for Process Applications
GROUND SERVICING OF VARIOUS SUB SYSTEMS
Refrigeration & air conditioning
25 YEARS OF ENERGY SAVINGS
AUTOMATIC ON-LINE BRUSHING FOR HEAT EXCHANGERS AND CONDENSERS
Air-Row Fans Minimize Freezer Door Sweating
Desuperheater Heat Transfer Device Manufactured by Maniks
Topic : Lubricants & Mechanism of lubrication
Presentation transcript:

CELEBRATING 30 YEARS OF ENERGY SAVINGS LUBRICATION ENHANCEMENT SYSTEM

MAIN BENEFITS CONSERVES CONSERVES energy REDUCES REDUCES friction of moving compressor parts during operation as well as start-up. QUIETS QUIETS the decibel level during operation. PROVIDES PROVIDES relief from service issues. RESTORES RESTORES heat exchange by eliminating oil fouling. SAVES SAVES time and money spent on repairs and downtime with payback times almost always less than 24 months.

REFRIGERATION CYCLE

How Frigi-Tech Works Frigi-Tech’s polarized molecules bond to the metal inside the system, preventing the insulating build-up of oil which occurs over time due to oil fouling. Frigi-Tech will cause the insulating layer of oil to return to the compressor where it belongs and no longer builds up on heat transfer surfaces.

Frigi-Tech will restore the efficiency in the condenser and evaporator coils by restoring the heat exchange.

Treatment Times Frigi-Tech is a one-time treatment. The only time additional Frigi-Tech is required is if and when a compressor is replaced or an oil change on a chiller.

FEATURES &BENEFITS FEATURESBENEFITS Increased heat transfer in the evaporator and condenser up to 25% Improved cooling with shorter cycle times, equating to less run time and energy used Reduction of frictionLower amp draw and reduced start amps Reduced noise and vibrationComfort of the mechanical rooms Lower operating temperatures of the oil and the compressor For every 10 degrees Celsius a motor runs hotter, it reduces its life by 50% Improved energy efficiencyPayback time realized in months and then all further savings go towards the bottom line.

TYPICAL BEARING WEAR Worn chiller bearing due to be replaced at the annual service. Frigi-Tech was introduced and the same bearing was reinstalled.

CONDITIONED BEARING AFTER Frigi-Tech This is the same bearing showing how Frigi-Tech conditioned the metal surfaces. This demonstrates how Frigi-Tech will reduce noise and vibration as well as reduce friction.

Despite the fact that this higher braking force was exerted 10 times longer than the dry test, or the pure oil test, the amount of bearing wear damage was significantly less when Frigi-Tech was added. This gives us the ability to say that we should double the remaining life of the compressor at the time Frigi-Tech is installed.

DO WE VOID MANUFACTURER’S WARRANTY ? FRIGI-TECH MEETS AND THEN EXCEEDS After the introduction of Frigi-Tech there was over 1,000% improvement in the mixture lubricating ability. The modified Falex test was used to determine lubricity. Frigi-Tech exceeded the 582 pound limits of the test.

TYPICAL DATAASTM TEST EMKARATE RL 68H FRIGI-TECH P.O.E. VISCOSITY cSt/100° D VISCOSITY cSt/212° D VISCOSITY INDEXD 2270?124 POUR POINT °F D °-40° FLASH POINT °F D °518° ANILINE POINT °F D 611?N/R DIELECTRIC STRENGTH KV D 877?39 COPPER STRIP CORROSION D SEALED CHAMBER DISCOLORATION D 1500(1.0) CLEAR(0) CLEAR CHLORIDES PPMD 808<5 FALEX MODIFIED WEAR TEST LUBRICITY RATING, LBS OF FORCE APPLIED * P.O.E. Oil VS. Frigi-Tech P.O.E. Blend SYNTHETIC COMPARASION

Insurance

SYSTEM COMPATABILITY Frigi-Tech is compatible with any hermetically or semi-hermetically sealed system regardless of tonnage size and refrigerant.

REFRIGERANT COMPATIBILITY Frigi-Tech is compatible with both new and old refrigerants Frigi-Tech has tremendous results with ammonia systems Frigi-Tech’s Special Blends are available for applications where synthetic oils are used

MAJOR BENEFITS Reduction in amperage and total kWh Shortens cycle time by restoring the heat exchange Conditions metal and reduces friction Provides protection of the internal seals Frigi-Tech is a one time application

ADDITIONAL BENEFITS Maintains volumetric capacity Reduces excessive heat generation Decibel level reduction Major reduction in mechanical failures Provides oxidation and corrosion protection $2,000, worldwide insurance coverage

SUMMARY Increases System Performance Increases Cooling Efficiency Environmentally Friendly Improves Net Profit due to Reducing kWh and Decreasing Mechanical Failures Payback times almost always less than 24 months.

Frigi-Tech has been installed in 42% of the countries in the world.

Contact Information 9103 EMMOTT RD. BOX #9 HOUSTON, TEXAS or