WORKING WITH X-RAYS Dr D E Dugdale October 2012 KEELE UNIVERSITY.

Slides:



Advertisements
Similar presentations
Topic 8. Gamma Camera (II)
Advertisements

TRAINING COURSE ON X-RAY FOR GP
THE EXTERNAL HAZARD.
Advanced Biomedical Imaging Lecture 3
University of Arkansas Environmental Health & Safety December, 2002
X Rays Medical Physics Notes.
X-Rays In Medicine Noadswood Science, 2013.
Wilhelm Conrad Röntgen
Image Reconstruction.
RADIATION PROTECTION PRINCIPLES.  Prevent the occurrence of the non-stochastic effect by restricting doses to individuals below the relevant thresholds.
32 P Module Objectives  To understand the physical nature of 32 P.  To understand the 32 P is both and internal and external radiation hazard.  To understand.
Medical Imaging X-Rays I.
CVT 102.  Time  Distance  Shielding.
Industrial Radiography
XL2 radiation Safety.
Imaging Science FundamentalsChester F. Carlson Center for Imaging Science Medical X-ray Imaging System Imaging Science Fundamentals.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Instrumentation Part 1.
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
Radioactivity – review of laboratory results For presentation on May 2, 2008 by Dr. Brian Davies, WIU Physics Dept.
University of Minnesota Duluth Radiation Safety Annual Refresher Training Radiation Protection Division Department of Environmental Health & Safety.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Factors affecting the X-Ray output
X-Ray Production & Emission
Industrial Radiography Basic Safety Requirements
THE EXTERNAL HAZARD Radiation Protection.
Dental Assisting Radiology
Quality Control Rad T 110.
Resident Physics Lectures Christensen, Chapter 6Filters George David Associate Professor Department of Radiology Medical College of Georgia.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
ANALYTICAL X-RAY SAFETY User Training Centre for Environmental Health, Safety and Security Management.
Radiation. Ionising Radiation Alpha Radiation Beta Radiation Gamma Rays X-Rays Neutrons.
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
Chapter 3 Radiation Safety Vet Tech Institute. Radiation should be respected not Feared! Safety is Always important! Safety is Always important! Stray.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Higher Physics – Unit 3 3.5Dosimetry and Safety. Activity of Radiation The activity of a radioactive source is the average number of nuclei decaying per.
Radiation Monitoring and Protection
X - RAYS IN DIAGNOSTICS D. Krilov
Basic radiation protection & radiobiology
Designing for Radiation Protection. Design Standards for Radiation Protection – Leakage Radiation.
30.1 X-rays and radioactivity
Nuclear Medicine Principles & Technology_I
Safe Use of Analytical X-ray Equipment. Part 1: The Effect of Ionising Radiation on Living Organisms and Dose.
Week 2 :Radiation Protection
X-Ray Diffraction Safety at UIC
Dosimetry & Safety. Activity The term 'Activity' of a source describes the (in)stability of the atoms within a substance. One atom decaying per second.
X-ray tube.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 12.1 : Shielding and X-ray room design Practical.
Radiation Protection RTMR 284 CHAPTER 20 PART II.
Training Module Preparation for “AERB norms, licenses and signage”
Topic 6 : Atomic and Nuclear Physics.
Radiation Protection RTMR 284 CHAPTER 21.
Ch 36 Radiation Protection Design
Industrial Radiography
X-RAY PRODUCTION AND EXPOSURE FACTORS
XL3 radiation Safety.
X-Radiation.
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
Resident Physics Lectures (Year 1)
RADIATION TERMS AND UNITS
X Rays Medical Physics Notes.
Example Example 1: A number of lead blocks and aluminium plates are placed in front of a radioactive source. The source emits ,  and  radiation.
Resident Physics Lectures (Year 1)
Occupational Radiation Dose Management
Occupational Radiation Dose Management
The dangers of radioactivity
Occupational Radiation Dose Management
Hp(10) irradiations for personal dosimetry traceability
The External Radiation Hazard
Phenotyping Facility X-ray Awareness Training
Presentation transcript:

WORKING WITH X-RAYS Dr D E Dugdale October 2012 KEELE UNIVERSITY

ROTATING ANODE GENERATOR

X-RAY SPECTRUM E max = eV

DOSE RATES Can be very high For anode of atomic number Z, operating voltage V, current I Unfiltered dose rate = D  ZVI/d 2 at a distance d Typical figures for V = 50 KeV, I = 10 d = 1 m D - 1 Sv per d = 10 cm D Sv per minute

Radiation burns ( 3 Sv ) in a time 1m ~ 3 10 cm ~ 2 secs. Using Ni filter or monochromator D  D/100 To have radiation level below maximum allowed ( 7.5 micro Sv/hr ) requires shielding of > 10 8

I = I o e - x =linear attenuation coefficient H 1/2 = 0.69/ X-RAY SHIELDING

For 50 keV X-rays H 1/ m in air H 1/2 - 3 cm in body tissue H 1/ mm in Pb For 50 keV X-ray energy I/I o = 1/10 for x = tenth value thickness = 0.23 mm For x = 2.3 mm therefore I/I o =

X-RAY LEAKAGE - Typical Arrangement Of X-ray Generator And Camera Leakage at joints must be less than 7.5  Sv/hr - but ALARA principle demands much less since extra shielding is reasonably achievable for X-rays

Perspex Shielded Enclosures Leaded Perspex outer shield

MINI MONITORS Soft X-rays ( < 30 keV ) do not easily penetrate Geiger -Muller ( GM )tube walls. Ideally tubes with Be end windows should be used - but even cheap general purpose GM tubes have some response down to 9 keV ( Cu K lines used in crystallography) For GM tube 10 keV 1 c/s ~ 1 micro Sv/hr ( background ~ 0.5 c/s ) 1 micro Sv/hr is only ~ 2 mSv/yr but nevertheless more shielding should be used if any count rate above background can be detected

PERSONAL MONITORS Film badges and thermoluminesent detectors can detect doses > 0.05 mSv (~ 1/40 annual background) Film badges are changed every month ( every 3 months for TLD’s) Not likely to detect accidental exposure to collimated beams but should detect any diffuse scattered radiation Wear at chest height with serial number facing outward

WORKING PROCEDURES Register each year as a radiation worker (so that dose and training records can be kept ) Follow the general rules of the University and the local rules of the Department for specific equipment and specific procedures Local rules and local training are given by research supervisors and RPS Never overide interlocks Never operate if warning lights fail or if equipment is malfunctioning Report all faults to the responsible technician immediately