6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Hassan Moezzi A New Approach Welcome to the Model Data Centre.

Slides:



Advertisements
Similar presentations
Challenges in optimizing data center utilization
Advertisements

Data Center Design Issues Bill Tschudi, LBNL
Green Datacenters solution March 17, 2009 By: Sanjay Sharma.
Bridging the Gap Optimizing Data Center Infrastructure Management
Assess > Plan > Deliver > Sustainon365.co.uk. Assess > Plan > Deliver > Sustainon365.co.uk Electrical Review PowerOn Briefing You cant save money until.
Clair Christofersen Mentor – Aaron Andersen August 2, 2012
Future Facilities and nlyte Software Provide Fully Integrated DCIM and CFD Software Solution &
Session Title: Demystifying Efficiency in the Data Center Utilizing Airflow as a System Presented By: Jon deRidder Enabled Energy.
1 Using CFD as a Guide When Making Changes to the Data Centre. Nagy Daniel Senior IT Manager Magyar Telekom Technical Unit, IT Operations Directorate.
Matt Warner Future Facilities Proactive Airflow Management in Data Centre Operation - using CFD simulation to improve resilience, energy efficiency and.
Certain information in this document is proprietary to the Province of BC, Q9 Networks Inc. and/or HP Advanced Solutions Inc. Provincial Data Centre Overview.
Dave Pearson, Director of Innovation IHEEM Conference 27 th October 2009 Using an Ammonia Chiller Plant to Deliver Lower Cooling Costs
Kensa Ground Source Heat Pumps Product Range & Installer Support Programme.
1 * Other names and brands may be claimed as the property of others. Copyright © 2010, Intel Corporation. Data Center Efficiency with Optimized Cooling.
Zycko’s data centre proposition The very best products and technologies Focus on what your customers need Turning products into solutions Wide range of.
REcycling of waste HEAT for Energy Reduction for Smart Cities REHEATER SC – a collaborative response to the FP7 Smart Cities 2013 Call.
AN INDUSTRY REVIEW THE OPPORTUNITY PROGRAM PLANNING A GO-TO-MARKET PLAN Utility EE Programs for Data Centers and IT MARK BRAMFITT, P.E. BRAMFITT CONSULTING.
Cooling Product Positioning
SEMI-THERM FEBRUARY 23, 2010 SANTA CLARA, CALIFORNIA Capturing efficiency opportunities in data centers has become a business imperative, allowing managers.
ENERGY EFFICIENT DATA CENTRES – AN OVERVIEW Professor Peter James.
Virtualizing Enterprises: Challenges Harrick M. Vin Vice President and Chief Scientist Tata Research Development and Design Centre, Tata Consultancy Services.
Ensuring Reliable Electricity Supplies Using Distributed Generation Gregory Tress Carnegie Mellon University.
1 NYSERDA Data Center Efficiency Program Columbia University Green Data Center Winter Workshop January 7 th, 2011.
Copyright Green Revolution Cooling
Thermal Management Solutions from APW President Systems
All content in this presentation is protected – © 2008 American Power Conversion Corporation Rael Haiboullin System Engineer Capacity Manager.
1. 2 New Computing Models, and What They Mean to the Small and Mid Sized Business Consumer How your business can make practical decisions between “The.
TIMKEN Bearing Diagnostics and Prognostics Using PI Reducing Unplanned Downtime Rich Browner - Program Manager Reliability Solutions The Timken Company,
Cutting the Green IT Hype: Fact vs. Fiction Kenneth G. Brill, Executive Director Uptime Institute Inc
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
© 2008 IBM Corporation Sales Training Power and Cooling Trends and Data Center Best Practices Ken Schneebeli STG Lab Services
Data Center 2025 An Industrywide Look at the Future of Data Center Ecosystems Lynette Gordon
Lucht circulatie in Data Centres een Low Speed Ventilation benadering Michiel de Jong, Low Speed Ventilation GreenIT EIA, Amsterdam, 2015.
On-Demand Architecture for Network-Critical Physical Infrastructure Large Data Centers Small & Medium Data Centers Computer Rooms & Closets David Blumanis.
WELCOME!. Page: 2 Agenda One is impressive – two make a powerful team! Networking solutions, the Extreme way Coffee Break Security solutions, the NetScreen.
Green IT and Data Centers Darshan R. Kapadia Gregor von Laszewski 1.
Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Virtualization and physical infrastructure – Integrations with Microsoft and VMware.
August 10, 2007 CONTROL YOUR DATA CENTER! Tune your Legacy Data Center to improve overall efficiencies.
Optimising Data Centre Power Planning and Managing Change in Data Centres - 28th November Cirencester.
R 255 G 211 B 8 R 255 G 175 B 0 R 127 G 16 B 162 R 163 G 166 B 173 R 104 G 113 B 122 R 234 G 234 B 234 R 175 G 0 B 51 R 0 G 0 B 0 R 255 G 255 B 255 Supporting.
Fitting GeoExchange Heating and Cooling to Your Building Denis Tanguay President & CEO Canadian GeoExchange Coalition High-Rise Power: Is renewable energy.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
Introduction to EMC.  Data Centre physical infrastructure specialist  Technical environment M&E.
Liam Newcombe BCS Data Centre Specialist Group Secretary Energy Efficient Data Centres.
Infrastructure Gina Dickson – Product Manager Kevin Jackson – Sales Manager.
ThinDesk, Inc.. What is Thin Computing?  IT Industry is buzzing about Green IT, Virtualization both in the Data Centre and on the Desktop, Public / Private.
Dealing with Hotspots in Datacenters Caused by High-Density Computing Peter Hannaford Director of Business Development EMEA.
Jon Walton Director of Technology Bay Area Technology Forum November 5, 2009 Technology Consolidation: Fact or Fiction.
Welcome Georgia Infrastructure Transformation 2010 Kick-off Meeting January 30, 2008.
Confidential VMware vCenter Promotion Available until June 15, 2010.
High Performance Computing (HPC) Data Center Proposal Imran Latif, Facility Project Manager Scientific & Enterprise Computing Data Centers at BNL 10/14/2015.
Computing Facilities CERN IT Department CH-1211 Geneva 23 Switzerland t CF CERN Computer Centre Consolidation Project Vincent Doré IT Technical.
Key Customer ChallengesCustomer Pain Points How You can Help the CustomerProductsSolutionsServices Increasing Density Difficult to maintain 300 cfm per.
Proven Leader in Infrastructure Performance Management (IPM) Revenue growth 100% yr. EMC Select Partnership launched November 2012 Virtual Instruments.
1 TEMENOS HOME Global Conference on Access to Finance Washington DC 30 th and 31 st May 2006 Murray Gardiner.
Ulrich (Uli) Homann Chief Architect, WW Enterprise Services Microsoft Corporation SESSION CODE: ARC305.
SueDon Ltd - Business Continuity Management BCM Overview ©1999 SueDon Ltd Business Continuity Management.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
1 PCE 4.4 New Development In DC Containment Steve Howell.
1 ITM 1.2 How IT Decisions Impact Data Center Facilities: The Importance of Collaboration Lars Strong P.E. Upsite Technologies, Inc.
Taking your Business Technology Further. First Communications: At A Glance Technology Provider since 1998, serving thousands of Businesses throughout.
Monitoreo y Administración de Infraestructura Fisica (DCIM). StruxureWare for Data Centers 2.0 Arturo Maqueo Business Development Data Centers LAM.
West Cambridge Data Centre Ian Tasker Information Services.
1 Copyright © 2016, The Green Grid The webcast will begin shortly Today’s live session will be recorded.
Dell EMC Modular Data Centers
How Machine Learning & Analytics Saved 1 Billion kWh
Using Heat to Increase Cooling George Hannah BEng (Hons) CEng MIMechE
Objective Use financial modeling of your data center costs to optimize their utilization.
AKSUM UNIVERSITY ICT Directorate Oct 10, 2018 Axum, Tigray, Ethiopia
Presentation transcript:

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Hassan Moezzi A New Approach Welcome to the Model Data Centre

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Operational Intent Mid life Expected end of life Year 1 Time Operational intent Usable Capacity of room Total available KW Capacity=W/m 2 x area

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 The Reality… Mid life Expected end of life Year 1 Time Typical Operation Operational intent Lost Lifespan Stranded Capacity Usable Capacity of room Total available KW Hot Spots create a mid-life crisis? Premature end-of-life for the data center. Hot Spots

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Why is there stranded capacity? IT operation decisions have engineering impact on: Efficiency (increased Opex through energy costs) Resilience (increased risk of thermal downtime) Longevity (increase in Capex caused by stranded capacity) Causes: IT Deployment decisions do not take into account the engineering impact of operational decisions IT Deployment decisions do not consider air flow/cooling management

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Lack of Airflow Management Did you know that all mission critical facilities lose more than 30% of their data center capacity because of hotspots? Why? IT Equipment is air cooled There are no standards for cooling design of IT Equipment. IT equipment designs change over time. IT equipment deployment changes over time. Data Center cooling infrastructure is fixed over its lifetime. The owner/operator has the responsibility to deliver sufficient airflow and cooling to every piece of IT equipment at all times. Servers Switch Storage

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Capacity planning is impossible without airflow management Same equipment, one works... one fails. Servers Switch Storage

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 The Physics of Airflow and Cooling Equipment Manufacturer No Man’s Land Facilities Manager There is a lack of effective communication between the Equipment Suppliers and the Building Services Industry

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Current Process Infrastructure IT Equipment Cabinets

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 What you’ll see today Infrastructure IT Equipment Cabinets The Virtual Facility The Virtual Facility is a full 3- dimensional mathematical representation of the physical data center at any point in time.

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Many teams... One goal Engineering based decisionsBusiness / Operational based decisions

6SigmaDC Conference & User Training, 15 th – 17 th November 2011 Closing Remarks Mid life Expected end of life Year 1 Time Typical Operation Operational intent Reclaimed Capacity Operating with a Virtual Facility Reclaimed Lifespan Capacity of room Total available KW “Data centers seldom meet the operational and capacity requirements of their initial design” - Gartner