What if you use a capillary, small specimen or transmission technique

Slides:



Advertisements
Similar presentations
(see Bowen & Tanner, High
Advertisements

Incident/Monochromated
Experimentally, the Bragg law can be applied in two different ways:
The waves spread out from the opening!
CHAPTER 3: CRYSTAL STRUCTURES X-Ray Diffraction (XRD)
Determination of Crystal Structures by X-ray Diffraction
Are your X-ray powder diffraction patterns any good? Are your X-ray powder diffraction patterns any good?
Introduction to Powder X-Ray Diffraction
I am not an expert on any of this!
IPCMS-GEMME, BP 43, 23 rue du Loess, Strasbourg Cedex 2
Beam Lines At SSRL Cathie Condron SSRL Scattering Workshop May 2007.
Submitted By:- Nardev Kumar Bajaj Roll NO Group-C
Cross section measurements for analysis of D and T in thicker films Liqun Shi Institute of Modern Physics, Fudan University, Shanghai, , People’s.
Neutron Scattering 102: SANS and NR
Visual Angle How large an object appears, and how much detail we can see on it, depends on the size of the image it makes on the retina. This, in turns,
The four-circle single crystal diffractometer.
1 Refinement parameters What are the parameters to be determined? atom positional parameters atom thermal motion parameters atom site occupancy parameters.
Near-surface diffraction capabilities at NECSA TP Ntsoane Diffraction Section 11 September 2015.
X-Ray Diffraction Dr. T. Ramlochan March 2010.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Other modes associated with SEM: EBIC
Accuracy-in-XRD.1, A. Kern © 1999 BRUKER AXS All Rights Reserved Accuracy and Precision in Powder Diffractometry A. Kern Bruker AXS GmbH Östliche Rheinbrückenstraße.
Beauty, Form and Function: An Exploration of Symmetry Asset No. 36 Lecture III-9 Laboratory Studies of Crystal Symmetry PART III Symmetry in Crystals.
Peter J. LaPuma1 © 1998 BRUKER AXS, Inc. All Rights Reserved This is powder diffraction!
X-Ray Measurement Methods From Chapter 6 of Textbook 2 and other references Diffractometer Hull/Debye-Scherrer method Pinhole method Laue Method Rotating.
The waves spread out from the opening!
D8DISCOVER-for-Material-Research.1: Dr. H. R. Reß © 1999 BRUKER AXS All Rights Reserved D8 DISCOVER for Material Research.
Motor driven incident slits (define the incident x-ray beam size) Synchrotron x-ray upstream beam aperture CCD camera Video camera Long working distance.
Interaction of X-Rays with Materials
1 Data Acquisition What choices need to be made?.
X-ray powder diffractometer X-ray powder diffractometer.
Least squares & Rietveld Have n points in powder pattern w/ observed intensity values Y i obs Minimize this function: Have n points in powder pattern w/
X-ray diffraction and minerals. Is this mineral crystalline?
The Muppet’s Guide to: The Structure and Dynamics of Solids XRD.
The Microscope and Forensic Identification. Magnification of Images A microscope is an optical instrument that uses a lens or a combination of lenses.
Parameters of the new diffractometer “ARES” Aleksey E. Sokolov PNPI NRC “KI”
MCNSI meeting, February 2006 Contents: People –V. Ryukhtin left for part time only Multichannel focusing benders – continuation –resolution functions.
A New High Intensity Cold Neutron Spectrometer at NIST J. A. Rodriguez 1,3, P. Brand 3, C. Broholm 2,3, J.C. Cook 3, Z. Huang 3, P. Hundertmark 3, J. Lynn.
X-ray Dynamic Defectoscopy (XRDD) Direct observation of damage development in time dependent gradually stressed materials by means of X-ray transmission.
复习 What did I learn in school today? 复习 What did I learn in school today?
Characterization of Nanomaterials 1- Scanning Electron Microscopy (SEM) It is one of the most widely used techniques in the characterization of the morphology,
Comparison b/w light and electron microscopes LIGHT MICROSCOPE ELECTRON MICROSCOPE Magnification can be done upto 2000 times Resolving power is less.
X-RAY METHODS FOR ORIENTING CRYSTALS
Prepared By – Amit $hah M.Pharm 1 st sem QA Roll NO :- 03 Guided By – Mr. Pinak R. Patel Assistant Professor Dept. P’ceutical Chem. D Dharmaj Degree Pharmacy.
Phys102 Lecture 26, 27, 28 Diffraction of Light Key Points Diffraction by a Single Slit Diffraction in the Double-Slit Experiment Limits of Resolution.
LIGHT BACKSCATTERING ANALYSIS of Textured Silicon SAMPLES
CHARACTERIZATION OF THE STRUCTURE OF SOLIDS
An-Najah National University New Campus, Nablus, Palestine
Powder x-ray diffraction
Davide De Salvador INFN-Laboratori Nazionali di Legnaro &
Reflectivity Measurements on Non-ideal Surfaces
Diffraction Literature:
Scott Speakman A x The X-Ray SEF Scott Speakman A x
TEM (Transition Electron Microscope)
Instrumentation systems
X – Ray Diffraction (XRD)
Wide Angle Scattering (WAXS) (Powder Diffraction) How do we do
ROTAN the X-Ray laboratory Daniel Šimek Jan Drahokoupil Zbyněk Šourek
X-ray Scattering from Thin Films
What did I learn in school today?
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
X-ray powder diffractometer.
Resident Physics Lectures (Year 1)
Institut Laue-Langevin
X-ray powder diffractometer.
Basic principles Geometry and historical development
Crystal and X-ray Diffraction
The waves spread out from the opening!
Examples of our own Tricks
{ What is usually going to cause you trouble? Texture effects
Presentation transcript:

What if you use a capillary, small specimen or transmission technique “Gun” Mount - Forensic Science Courtesy Forensic Science Laboratory - Germany Film Mount Courtesy Forensic Science Laboratory - Germany Transmission – Combinatorial Analysis - Courtesy Bruker-AXS

Glass Capillary Mount Courtesy of PANalytical

Number of Particles - Reflection Volume of sample in X-ray beam V= (area of beam) (2x half-depth of penetration) Assume area = 1cm x 1cm = 100mm2 t1/2 = 1/m,where m = linear absorption coefficient mSiO2 = 97.6 cm-1 ~ 100 cm-1 = 10 mm-1 V = (100) (2) (10-1) mm3 = 20 mm3

Number of Particles – Capillary Volume of sample in X-ray beam V= (width of beam) (cross-sectional area of capillary) For a 0.7 mm internal diameter capillary V= (width of beam) (0.1225 mm2)  For a 1 cm-wide beam, V = 3.85 mm3 For a 1 mm-wide beam, V = 0.385 mm3 ! However, capillary rotation brings many more particles into Bragg alignment

{ What is usually going to cause you trouble? Texture/orientation effects - affects peak intensity Sample displacement - affects peak 2q position { Bad particle statistics with thin films, small specimens and capillaries Well aligned capillary, film, or transmission system can greatly reduce displacement errors. These systems frequently have an alignment telescope or laser.

Cue for capillary sample preparation movies

Collimators, Slits, Mirrors, Capillaries Control Divergence Tube Tube Glass Capillary Mount Courtesy of PANalytical Transmission – Combinatorial Analysis - Courtesy Bruker-AXS Collimators, Slits, Mirrors, Capillaries Control Divergence

Capillary Technique / Goniometer Head Mark Tubes for μg Specimen : Adjusting the Specimen with the Crosshair and the Laser Spot of the Video Sample Alignment System In most cases the Mark tubes are fastened to a goniometer head. This is screwed onto an additional Phi-circle, which is fastened to the XYZ-stage. The Phi – circle is a particularly attachment of our GADDS system. The specimen is adjusted with the crosshair of the video microscope and the laser spot of the video sample alignment system to the instrument center. Mark Tube on a Goniometer Head Additional Φ-Circle, Fastened to the XYZ - Stage

Fixed / Rotated Specimen Sample Fixed: Sample Rotated: This image shows the data frame from a fixed and from a rotated specimen. Due to the non-isotropic specimen structure - large grains and preferred orientation- the intensity distribution along the Debye-Scherrer cones is inhomogenous in the case of the fixed specimen. In order to obtain better statistics, we prepare most powder specimen with the capillary technique and we use the rotation mode with the phi-circle. Courtesy Forensic Science Laboratory - Germany

I = I e I = Transmitted Intensity I = Incident Intensity - ut o I = Transmitted Intensity I = Incident Intensity u = mass absorption coefficient t = sample thickness o 0.1 cm or less thick, u most organics <10 cm-1

Test of influence of capillary diameter Sample: tetracycline hydrochloride Set of different capillaries: 0.3 mm, 0.5 mm, 0.7 mm, 1 mm, 2 mm Goal: determine influence of capillary diameter on resolution and intensity Data Courtesy of PANalytical

Zoom-in of first peak Data Courtesy of PANalytical Counts 0.3 mm 40000 22500 10000 2500 Data Courtesy of PANalytical 8.40 8.60 8.80 9 Position [°2Theta]

Optimum capillary diameter Sample Absorption Insufficient Volume of specimen in the beam Data Courtesy of PANalytical

Comparison with parabolic mirror   Parallel Beam Parabolic mirror Data Courtesy of PANalytical

Capillaries and Small Specimens Accurate d-spacings Intensity fluctuations Increase collection area (2D detector) Rotate specimen

Summary Experimental Goals and Specimen Parameters Specimen for accurate d-spacing Ideal: Thin specimen Grain size ~ 20-40 mm Purpose: Low penetration Sharp well-resolved peaks Uses: Identification Accurate cells

Summary Experimental Goals and Specimen Parameters Specimen for accurate intensities Ideal: Thick specimen Grain size ~ 1mm Purpose: Avoid preferred orientation Produce smooth profiles Uses: Quantification Structure analysis

Summary Special specimen problems Solid specimens Residual stresses may cause line shifts Large solid specimens Special supports and shielding Thin layers Grazing beam limits penetration Special attachment collimators diffracted rays Reactive specimens Protect from atmosphere Toxic specimens Confine sample

Summary Special specimen problems Radioactive specimens Confine sample and block radiation Small specimens Limited non-specimen scattering Shaped particles Deliberately orient particles Dust specimens Collect on filters